![A&D HW-10KGL Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/aandd/hw-10kgl/hw-10kgl_instruction-manual_3949289056.webp)
Page 54
HV-G/HW-G Series
15. The Function Table
Item
Display Description
A
f8 4
When the display is a stable value and not nearly-zero, the scale
accumulates the data automatically. The next accumulation can
be performed after the display becomes nearly-zero.
Use
Recording the number and mass of articles removed
from the pan. (Place the articles on the pan. Press the
TARE
key at each removal.)
A
A
A
A
A
A
Accumulation
function
f8 5
At each end of the full/dribble batch function, the scale
accumulates the data automatically.
Use
Packaging articles like a powder, it is used for recording
the bag number and total mass.
A
A
A
A
Selects the printing condition. Option OP-06 for type V is
required.
A
f9 0
# No
print.
A
f9 1
Press the
key to output the data.
A
f9 2
Auto-print +
When the display becomes a positive stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero or negative value.
A
A
A
A
A
f9 3
Auto-print +/-
When the display becomes a stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero.
A
A
A
A
f9 4
At each end of full/dribble batch function, the data is output.
A
Print mode
f9 5
When the accumulation function is used, the data is output.
A
Selects the details of the full/dribble batch function (
f6 9
)
A
f10 0
#
When the
F
key is pressed after final value is reached, the
current process is finished.
A
A
f10 1
When the stability mark is displayed after final value is reached,
the current process is finished automatically.
A
A
f10 2
When the
SET
key is pressed, the scale automatically tares and
starts the full/dribble batch process. When the
F
key is pressed
after final value is reached, the current process is finished
A
A
A
Full/Dribble
batch
sub-func-ti
on
f10 3
When the
SET
key is pressed, the scale automatically tares and
starts the full/dribble batch process. When the stability mark is
displayed after final value is reached, the current process is
finished.
A
A
A
Select the address for RS-422 / RS-485 for option OP-04
A
f11 00
#
Address
f11 01
to
f11 99
Use Addresses from 01 to 99 are available. Scales are
assigned unique addresses and are controlled by the
computer.
(RS-232C should be set to "00".)
A
A
A
"#": factory settings. The "nearly-zero" is within
±
5 digits from zero point in the unit of kg.
Содержание HW-10KGL
Страница 19: ...HV G HW G Series Page 17 6 Description of Each Part 6 Description of Each Part...
Страница 20: ...Page 18 HV G HW G Series 6 Description of Each Part...
Страница 67: ...HV G HW G Series Page 65 17 Options For models with weighing capacity of 300 kg to 1200 kg...
Страница 81: ...HV G HW G Series Page 79 18 Specifications Dimensions Unit mm...
Страница 82: ...Page 80 HV G HW G Series 18 Specifications Unit mm...
Страница 84: ...Page 82 HV G HW G Series MEMO...
Страница 85: ...HV G HW G Series Page 83 MEMO...
Страница 86: ...Page 84 HV G HW G Series MEMO...