Digital Platform Scale 

 

Global models   

HV-15KC HV-15KCP 

HV-60KC HV-60KCP 

HV-200KC HV-200KCP 

HW-10KC HW-10KCP 

HW-60KC HW-60KCP 

HW-100KC HW-100KCP 

HW-200KC HW-200KCP 

 

Region - limited models 

HV-300KC HV-300KCP 

HV-600KC HV-600KCP 

HW-300KC HW-300KCP 

HW-600KC HW-600KCP 

 
 
 
 
 
 

1WMPD4003471B 

Содержание HV-C Series

Страница 1: ...HV 15KC HV 15KCP HV 60KC HV 60KCP HV 200KC HV 200KCP HW 10KC HW 10KCP HW 60KC HW 60KCP HW 100KC HW 100KCP HW 200KC HW 200KCP Region limited models HV 300KC HV 300KCP HV 600KC HV 600KCP HW 300KC HW 300...

Страница 2: ...ated into any language in any form by any means without the written permission ofA D Company Ltd The contents of this manual and the specifications of the instrument covered by this manual are subject...

Страница 3: ...5 4 Grounding the Scale 17 5 4 1 Method A Procedure to Ground the Scale 17 5 4 2 Method B Procedure to Ground the Scale 17 5 4 3 Method C Procedure to Ground the Scale 17 6 Description of Each Part 1...

Страница 4: ...Preparation 49 14 2 3 Calibration of the Zero Point 50 14 2 4 Span Calibration 50 15 Function Table 51 15 1 Parameter Setting Procedure 51 15 2 Parameter List 52 15 3 Initializing Parameters of the Fu...

Страница 5: ...on the sample weight multi interval The HW 300KC HW 300KCP HW 600KCP and HW 600KC are platform scales with 1 6000 resolution Other HW models are platform scales with 1 10000 resolution Type CP scales...

Страница 6: ...erval The minimum display is automatically switched depending on the sample weight When exceeding the small medium or large ranges the interval of display is automatically switched Example of an HV 60...

Страница 7: ...lay unit cover to avoid damage Do not use an unstable power source Remove the protective film from the weighing pan before use 30 minutes before the scale is used connect the power the AC adapter or b...

Страница 8: ...tle running tap water Do not scratch the base unit with a brush Allow the unit to dry before using Caution The base units of the following models are not waterproof HV 300KC HV 300KCP HV 600KC HV 600K...

Страница 9: ...from the weighing pan before use Step 3 Assemble the pole Attach the pole to the bracket of the base unit taking care not to damage the load cell cable Insert the remainder of the load cell cable int...

Страница 10: ...st cable length Close the bracket cover Step 6 Assemble the base unit and pole Affix the pole and base unit using four hex screws and flat washers so as not to damage the load cell cable Use the hex w...

Страница 11: ...n HV 60KC HV 60KCP HW 60KC HW 60KCP Weighing pan Base unit Caution Do notpull theloadcell cable Caution Do notpull theloadcell cable Accessories Accessories supplied depend on the scale Refer to 5 1 A...

Страница 12: ...Accessories Accessories supplied depend on the scale Refer to 5 1 Accessories and Options List Displayunitcover AC adapter AXP 3003217D Please confirm that the AC adapter type is correct for your loca...

Страница 13: ...C Ableto use battery HV 300KC HV 600KC HW 300KC HW 600KC Displayunitcover AXP 3003217D Cableclamp 2 Setof hexscrewsforpole withhex wrench Bracket cover 1 4mmscrewsfordisplayunit 4 Cabletie 1 5mmscrews...

Страница 14: ...60KC HV 60KCP HW 60KC HW 60KCP FW 15 Stand for the display unit The display is not included FW 16 4 Wheel FW 18 4 Roller conveyor for L2 models HV 300KC HV 300KCP HV 600KC HV 600KCP HW 300KC HW 300KC...

Страница 15: ...nbatteriesareconsumedmostly thebatterymark isdisplayed Replacebatterieswithfournew ones when isdisplayed Donotmix usedandnew batteries Donotuse batteriesofdifferenttype andmanufacturer Doingsomaycause...

Страница 16: ...600KCP HW 300KC HW 300KCP HW 600KC HW 600KCP Method Bprocedure toremovethepole 5 3 1 Method A Procedure to Remove the Pole HV 15KC HV 15KCP HV 60KC HV 60KCP HV 200KC HV 200KCP HW 10KC HW 10KCP HW 60KC...

Страница 17: ...pole and bracket from the base unit using a hex wrench Hex wrench 5 mm HV 15KC HV 15KCP HV 60KC HV 60KCP HW 10KC HW 10KCP HW 60KC HW 60KCP Hex wrench 6 mm HV 200KC HV 200KCP HW 100KC HW 100KCP HW 200K...

Страница 18: ...pull on the connector forcibly Step 6 Arrange the cable so it does not touch the weighing pan in the base unit If the cable is untied the straight length of L2 models is approximately 4 5 m The lengt...

Страница 19: ...ethod A Procedure to Ground the Scale HV 15KC HV 15KCP HW 10KC HW 10KCP Secure the grounding wire using an M4 screw in the screw hole between the two hexagon bolts on the base unit bottom side Part 5...

Страница 20: ...s HV 200KC HV 200KCP Cap HW 100KC HW 100KCP Cap Pole HW 200KC HW 200KCP Pole Leveling foot Base unit Weighing pan SUS430 Display unit of type C Leveling foot Base unit Weighing pan SUS430 Display unit...

Страница 21: ...CP Display unit HW 600KC HW 600KCP Cap Pole Bubble spirit level Leveling foot Base unit Weighing pan SUS430 Display unit of type C Display unit of type CP CAL switch Type CP Calibrate the scale to wei...

Страница 22: ...ile the accumulation function is used Low battery mark for type C This mark is displayed when the battery is close to being depleted voltage is low Replace with four new batteries Comparator indicator...

Страница 23: ...bration weight is too heavy Check the base unit and the weighing pan Fixed display An error where the zero value cannot be displayed because the weighing value is unstable when the scale turns on Remo...

Страница 24: ...a positive stable value and the TARE key is pressed the scale displays a zero value as net value net mark and zero point mark The net value is a value obtained by subtracting the value of tare weight...

Страница 25: ...the built in printer Type CP Press and hold the SET key and press the M key Use these keys to display the accumulated results Press and hold the SET key and press the COMP key Use these keys to set li...

Страница 26: ...p 7 Gently place an article to be weighed on the weighing pan Step 8 Wait for the stability mark to be displayed Read the weighing value Step 9 Gently remove the article from the weighing pan Step 10...

Страница 27: ...not to be used for a long time Leaving them installed may result in leakage and cause a malfunction and damage to the scale 7 1 3 Power on Zero Function and Power on Tare Function Power on Zero Functi...

Страница 28: ...zero and the net mark is displayed Step 2 Place an article to be weighed in the container Wait for the stability mark to be displayed and read the net display Step 3 Remove all of the articles and the...

Страница 29: ...be displayed The weighing unit used when turned on is the last weighing unit used before turning off Ib oz display is available only with HV 15KC HV 15KCP HW 10KC and HW 10KCP lb oz weighing oz weigh...

Страница 30: ...p 4 Place the container on the weighing pan Press the TARE key Step 5 Place the number of samples selected at step 3 Wait for the stability mark to be displayed Press the ENTER key to store The count...

Страница 31: ...cle Refer to 8 1 Storing a Unit Mass Step 3 Place the container on the weighing pan Press the TARE key Step 4 Place articles in the container Wait for the stability mark to be displayed and read the c...

Страница 32: ...off standby mode Display and Key Operations of Accumulation Function The display of the accumulation count has a blinking M without a weighing unit The display of the accumulation mass value has a wei...

Страница 33: ...value is a negative stable value and not near zero if the M key is pressed the negative value is subtracted from the accumulation value The next accumulation can be performed after the display becomes...

Страница 34: ...5 HIHI Out of range Positive value To use the comparator modes item and of the function table must be specified and threshold values limit values of the comparator must be set in advance Select a comp...

Страница 35: ...p 3 Item is displayed Input a parameter for the mode using the numerical keys Press the MODE key to proceed to next step Step 4 Item is displayed Input a parameter for the comparison method using the...

Страница 36: ...playedvalue Out ofrange Negativevalue LOLO Red LOLO OK LOlimitvalue Displayedvalue HIlimitvalue OK Green OK HI HIlimitvalue Displayedvalue or Out ofrange Positivevalue Displayedvalue HIHI Red HIHI Cau...

Страница 37: ...hreshold values are maintained even if the power supply is off Ignore the decimal point when setting threshold values of limits and ranks Comparison is performed in order from the top row to the botto...

Страница 38: ...00 kg HIHI 12 000 kg Example HV 200KC LO 148 85 kg HI 152 50 kg Example HV 15KC Rank1 LOLO 0 500 kg or more Rank2 LO 1 000 kg or more Rank3 OK 1 500 kg to 2 000 kg Rank4 HI up to 2 500 kg Rank5 HIHI u...

Страница 39: ...een on and off by pressing the corresponding key Corresponding numerical key _1_ _2_ _3_ _4_ _5_ LED for the comparison result LOLO LO OK HI HIHI Image of display during setup Example When the result...

Страница 40: ...nction together with the auto tare function enabled In this operation mode the scale operates as take away the objects OK and stable auto tare take away the objects In this setting the polarity of LOL...

Страница 41: ...ration and Print Samples While pressingandholdingthe SET key pressthe PRINT key Paper feed is performed Thefollowingexample is whentheprintmode inthefunctionsettings is selected Printing example for B...

Страница 42: ...ult is printed 12 1 1 Installing the Roll Paper Step 1 Pull the printer cover toward you to open it Step 2 Install the roll paper so that the end of the paper is at the top Step 3 Close the printer co...

Страница 43: ...power on and enter the function setting mode appears Step 2 Press the MODE key several times to display Step 3 Press the ENTER key Enter the ID number using the following keys M key The blinking digit...

Страница 44: ...calkeys Avaluecanbe inputatthe blinkingdigit 1ZERO key Tocancelsettingsandproceedtostep5 Step 5 Press the ENTER key after finishing setting A setting value is registered and the scale proceeds to time...

Страница 45: ...7 printer use Format of AD 8121B or AD 8127 or in the function table Use MODE 3 for the AD 8121B Use DUMP print mode for the AD 8127 If the GMP report is output to a personal computer use the general...

Страница 46: ...d in 14 2 4 Span Calibration Step 4 With nothing on the weighing pan press the ENTER key The zero point is measured and the measured value with the unit kg is displayed for a few seconds Then the valu...

Страница 47: ...the Title block The scale automatically returns to the weighing mode Step 2 Press the PRINT key or select the auto print mode to output the weighing values Pressandhold Tooutputthe Titleblock Tooutpu...

Страница 48: ...ressandhold Tooutputthe Endblock Manufacture Model ID number Date Startingtime Column for signature Weighing value Ending time End block Serial number A D CRLF MODE L H V 1 5 K C CRLF S N 6 A 6 1 2 3...

Страница 49: ...djust the zero point so that the zero point mark is displayed when there is nothing on the weighing pan Comment The zero point is the reference point for weighing and influences the performance of sca...

Страница 50: ...Paris 9 809 m s2 Chicago 9 803 m s2 Rio de Janeiro 9 788 m s2 Copenhagen 9 815 m s2 Rome 9 803 m s2 Cyprus 9 797 m s2 San Francisco 9 800 m s2 Djakarta 9 781 m s2 Singapore 9 781 m s2 Frankfurt 9 810...

Страница 51: ...leration using the numerical keys Step 4 Press the ENTER key to store the new value The display returns to gravity acceleration display after displaying Step 5 Press the CAL switch again to finish gra...

Страница 52: ...o step 14 14 2 4 Span Calibration Step 6 Set the value of the calibration mass using the numerical keys The initial value depends on the scale model Step 7 Place the calibration weight on the weighing...

Страница 53: ...y press the ON OFF key to display software version Press the MODE key to enter function setting mode First class is displayed Step 2 Press the MODE key to select the desired class and then press the E...

Страница 54: ...power using the AC adapter OFF Zero tracking ON 0 5 digit 1 digit Stability band width 2 digits 0 5 seconds 1 0 second Stability band time 1 5 seconds Condition for lighting stability mark Factory se...

Страница 55: ...by the HOLD key during stabilization Holdcondition Automatically holds when detecting stabilization Does not sound All LEDs are turned off Buzzer Method for lighting LED When lighting up the LED regi...

Страница 56: ...re Nocontact 2400 bps 4800 bps Baudrate1 OP ch1 9600 bps 7 bit even 7 bit odd Bitlength parity1 OP ch1 8 bit non Format 1 Format 1 existing returned value Communicationformat1 OP ch1 UFC 2400 4800 Bau...

Страница 57: ...nt an accumulation value when the accumulation operation is made commands Do not output the date and time Output time ESC T 2 Output date ESC D 2 Outputdateandtime ESCD ESCT 2 Parameteravailable when...

Страница 58: ...Print an accumulation value when the accumulation operation is made commands Do not output the date and time Output time ESC T 2 Output date ESC D 2 Outputdateandtime ESCD ESCT 2 Parameteravailable wh...

Страница 59: ...stable when the comparator is OK Built inprinter outputmode Print an accumulation value when the accumulation function is used Do not output the date and time Output time RTC Output date RTC Time and...

Страница 60: ...nction table Parameters of the comparator are reset as well Step 1 Turn off the display using the ON OFF key Step 2 While pressing and holding the TARE key press the ON OFF key to display Step 3 Press...

Страница 61: ...lot for OP ch3 Installation example OP ch1 HVW 03C OP ch3 OP ch2 HVW 02CB HVW 04C OP ch3 HVW 04C OP ch2 OP ch1 HVW 02CB HVW 03C 16 1 Installing Options Step 1 Remove the two M3 screws at both side on...

Страница 62: ...s a COM port Step 3 Read the COM port number on the computer Step 4 Input the number to the data communication software Step 5 Connect the scale to the computer using the USB cable Step 6 When the PRI...

Страница 63: ...munication software WinCT is used data can be stored in memory Step 1 Start RsCOM of WinCT for example Step 2 Prepare parameters of Port COM Port number is 9 in the example Note The communication soft...

Страница 64: ...Direction Description 1 No connection 2 TXD Transmit data 3 RXD Receive data 4 No connection 5 GND Signal ground 6 DSR Data set ready 7 RTS Request to send 8 CTS Clear to send 9 Used internally Inside...

Страница 65: ...of HVW 04C Manufacturer PHOENIX 7 mm Model name MSTB 2 5 6 STF 5 08 Wire Caution When the three level comparator mode is used the comparator outputs are the HIHI 1pin OK 3 pin and LOLO 5 pin HI 2 pin...

Страница 66: ...tch can be assigned at the external contact input in the function table The function of the switch can be assigned at the external contact input in the function table When the wire or wire is shorted...

Страница 67: ...9 9 9 9 9 9 k g CR LF HV C CP model S T 0 0 1 2 3 4 k g CR LF When the position of the minimum display changes depending on the weighing range the hidden digit is replaced to Example of tare function...

Страница 68: ...lue falls to 4d or below Auto print mode data and OK Specify or in the function table When the weighing value is stable and OK as a comparison result at 5d and above or 5d and below the data is output...

Страница 69: ...tused Inseven levelcomparatormode Threshold valueof rank5 isoutput H2 Infive levelcomparatormode HIHI limit valueisoutput Inthree levelcomparatormode HIlimit value isoutput Inseven levelcomparatormode...

Страница 70: ...Inseven levelcomparatormode Theupperthreshold value of rank3is stored L1 Infive levelcomparatormode LOlimit valueis stored Inthree levelcomparatormode Notused Inseven levelcomparatormode Thelowerthre...

Страница 71: ...ghing value is stable Net value is displayed when the scale is in a condition where tare operation is possible Command T CR LF Reply T CR LF Net value has been displayed No reply If is set To switch t...

Страница 72: ...o request the ID number The ID number is output Command I D CR LF Reply I D A B C 1 2 3 CR LF To output the preset tare value The preset tare value is output Command P T CR LF Reply P T 0 0 0 0 1 2 0...

Страница 73: ...de LOLOlimit valueisoutput Three level comparator mode LOlimit valueis output Seven level comparator mode Threshold valueof rank2isoutput Command L 2 CR LF Reply L 2 0 0 0 1 0 0 CR LF To output L3 val...

Страница 74: ...mit valueis stored Three level comparator mode Notused Seven level comparator mode Thelowerthreshold value of rank3is stored Input the parameter of 6 digits excluding the polarity and decimal point Te...

Страница 75: ...nd cannot be finished the response I is returned Command Z CR LF Reply I CR LF The scale is not in a condition that zero operation is possible When the scale receives a command that it cannot identify...

Страница 76: ...Text Data to the Scale Command P F P C T E X T 2 0 S P 2 C R L F W T C R L F CR LF Reply P F CR LF Terminator The text data the UFC format can sent using the PF command Variable parameters for the sca...

Страница 77: ...s Variable parameters of the scale data are replaced with the following data format Data is a fixed length that includes a sign and a decimal point The leading zeros of data are replaced with spaces 2...

Страница 78: ...e parameter Example of date for built in printer Type CP YYYY MM DD 10 digits 2 0 1 8 3 1 8 TM of variable parameter Example of time for built in printer Type CP HH MM SS 8 digits 1 2 3 4 5 6 Printing...

Страница 79: ...cond Repeatability Standarddeviation kg 0 001 0 002 0 005 0 005 0 01 0 02 0 02 0 05 0 1 Linearity kg 0 001 0 002 0 005 0 005 0 01 0 02 0 02 0 05 0 1 Span drift 20 ppm C typ 5 C to 35 C HV C AC adapter...

Страница 80: ...ion kg 0 002 0 01 0 02 0 04 Linearity kg 0 002 0 01 0 02 0 04 Span drift 20 ppm C typ 5 C to 35 C HW C AC adapter Please confirm that the AC adapter type is correct for your local voltage and receptac...

Страница 81: ...C AC adapter Please confirm that the AC adapter type is correct for your local voltage and receptacle type The AC adapter may not be provided for some areas 50Hz 60Hz Battery TYPE D R20P R20PU LR20 x...

Страница 82: ...se confirm that the AC adapter type is correct for your local voltage and receptacle type The AC adapter may not be provided for some areas 50Hz 60Hz Battery TYPE D R20P R20PU LR20 x 4 Power source HW...

Страница 83: ...CP Series Page 81 Dimensions S models HV 15KC HV 15KCP HW 10KC HW 10KCP 494 255 43 250 366 104 180 35 180 201 250 330 M models HV 60KC HV 60KCP HW 60KC HW 60KCP 640 255 750 43 424 105 240 45 334 187...

Страница 84: ...200KC HV 200KCP HW 100KC HW 100KCP HW 200KC HW 200KCP 390 746 255 43 750 530 129 300 45 440 187 L2 models HV 300KC HV 300KCP HV 600KC HV 600KCP 600 HW 300KC HW 300KCP HW 600KC HW 600KCP 943 255 40 18...

Страница 85: ...eighing pan Perform zero point calibration is displayed and does not proceed The weighing value is unstable due to drift vibration or other factors A breeze or vibration may be affecting the measureme...

Страница 86: ...gth Parity1 54 Bitlength Parity2 54 Baudrate1 54 66 Baudrate2 54 66 Bracketcover 8 10 11 Bitlength Parity1 54 Bitlength Parity2 54 Bubblespiritlevel 7 8 18 19 Built inprintercommunicationformat 54 Bui...

Страница 87: ...ble 12 15 HVW 11C Wallmountingkit 12 HVW 13 RollerconveyorforL models 12 HVW 14 RollerconveyorforM models 12 HW C CPseries 3 7 41 IDnumber 41 57 IDnumber 39 41 43 46 55 56 IDnumberoutput 55 57 ID Comm...

Страница 88: ...ringtare 54 Spancalibration 47 50 Spandrift 77 80 Stabilitybandtime 52 Stabilityband width 52 Stabilizationlevel 52 Standforthedisplayunit FW 15 12 StatusofLEDwhenturningondisplay 54 Stabilityband wid...

Страница 89: ...HV HW C CP Series Page 87 MEMO...

Страница 90: ...Page 88 HV HW C CP Series MEMO...

Страница 91: ...13...

Страница 92: ...44 1235 550485 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bldg 33 Gukjege...

Отзывы: