background image

45

q

To print date/time, set 

f-06

f-06

f-06

f-06

/

07

07

07

07

/

08-02

08-02

08-02

08-02

 at "

1

####" (# = 

0

 or 

1

).

q

The total data (accumulated by the    M+    key) will be printed along with the number
of additions to 

M+

 memory.

The AD-8121 / MODE 3 does not have statistical functions.

AD-8121 Printout Sample

AD-8121 Printout Sample

AD-8121 Printout Sample

AD-8121 Printout Sample

MODE 1

MODE 3

11-5. Command Mode

11-5. Command Mode

11-5. Command Mode

11-5. Command Mode

q

In the command mode, the scale is controlled by commands that come from an
external device, computer etc.

Do not set 

f-06

f-06

f-06

f-06

/

07

07

07

07

/

08-01

08-01

08-01

08-01

="

1

11

1

" (stream mode) to use with the command mode. if you

don’t want to use command mode together with key mode or auto-print mode, set

f-06

f-06

f-06

f-06

/

07

07

07

07

/

08-0

08-0

08-0

08-0

1

="

4

44

4

" (command mode only).

q

Use a D-sub 9 pin cable (straight type) to connect with a computer.

Command List

Command List

Command List

Command List

Command

Definition

Notes

@

Start / stop continuous data transmission.

A

Same as 

 

RESET

 

 key.

Key command

D

Set a known tare weight.

“D,1.23C

R

L

F

” sets the tare

weight as "1.23kg".

E

Store the unit weight in use, other values and
specified item code to ID memory.

Refer to the data format.
Refer 

f-01-05

F

Recall unit weight from ID memory.

“F123C

R

L

F

” recalls from

ID000123.

ID Number

Item code

pcs (count)

Weight

Unit weight

No. of Accum.

TOTAL

      
      
QT      +1241 PC
WT     +3.155 kg
UW    +2.5427  g
      *
QT      +1272 PC
WT     +3.233 kg
UW    +2.5427  g
      *
AQ      +2513 PC

ID     000123
    ABCDEFGHIJKL
QT      +2168 PC
ST     +3.104 kg
UW    +1.4316  g

ID     000123
    ABCDEFGHIJKL
QT      +1989 PC
ST     +2.848 kg
UW    +1.4316  g

N           2
TOTAL   +4157 PC

Содержание FC-50Ki

Страница 1: ...Counting Scale FC 50Ki FC 20Ki FC 10Ki FC 5000i WM PD4000541...

Страница 2: ...translated into another language without the prior written consent of the A D Company Product specifications are subject to change without any obligation on the part of the manufacture Compliance wit...

Страница 3: ...To Clear TARE 18 4 STORE UNIT WEIGHT 19 4 1 Store Unit Weight by ID Numbers 19 4 2 Clearing A Stored Unit Weight 20 4 3 Store Item Code by ID Number 21 4 4 Unit Weight Tare Comparator Limits Total Co...

Страница 4: ...Mode 43 11 3 Connecting the AD 8121 Printer MODE 1 or MODE 2 44 11 4 Connecting the AD 8121 Printer MODE 3 44 11 5 Command Mode 45 12 OPTIONS 51 12 1 OP 02 Ni MH Battery Pack 51 12 2 OP 03 2 Ch RS 232...

Страница 5: ...cale on a suitable weighing surface Refer to Best Conditions For Best Conditions For Best Conditions For Best Conditions For Weighing Weighing Weighing Weighing of next page and turn the adjustable fe...

Страница 6: ...tuations q The weighing room should be kept clean and dry q The weighing table must be of a solid construction q Corners of rooms are best as they are less prone to vibrations q Don t install the scal...

Страница 7: ...his mode only front panel keys that would be used in 2 3 Unit Weight By a Sample 2 3 Unit Weight By a Sample 2 3 Unit Weight By a Sample 2 3 Unit Weight By a Sample counting operations are active All...

Страница 8: ...y the following 1 When the three UNIT WEIGHT BY LED s are blinking at display ON or if the RESET key has been pressed 2 Press the ID key id 000000 will be displayed with 000000 blinking 3 Press the EN...

Страница 9: ...ter of zero The KEYBOARD TARE key allows entering a known tare weight from the 10 key pad The TARE key subtracts the tare weight The STOREUNITWEIGHT key stores the unit weight on display item code dat...

Страница 10: ...ain and the scale returns to the standby mode ZERO ZERO ZERO ZERO q The ZERO key will bring the weight display back to zero as long as the weighing pan is empty or within 2 of capacity 1 Remove everyt...

Страница 11: ...ta to become stable 4 The scale will subtract the weight of the container and the weight display changes to net weight q The TARE ENTERED indicator will indicate STABLE 8888810 F I W2WEIGHT kg 1213456...

Страница 12: ...t of one item of what you are counting and refer to the section noted for more instructions STABLE 8888810 F I W2WEIGHT kg 12134567890 000 23ASAMPUW g 123415670 000004567890123456 7 ZERO TOTAL M TARE...

Страница 13: ...ting If you refer to the Add Sample display again then add the additional number of sample pieces displayed q You can ignore the Add Sample message and continue counting by pressing the ENTER key Howe...

Страница 14: ...eight of the pieces will be displayed 5 Press the ENTER key The display will show for a moment while calculating the unit weight After a moment the display will show the count total weight and unit we...

Страница 15: ...l be displayed 5 Press the ENTER key The display will show for a moment while calculating the unit weight After a moment the display will show the count total weight and unit weight If the Add Sample...

Страница 16: ...a sample size of 20 4 Press the ENTER key The display will show dashes for a moment while calculating the unit weight After a moment the display will show the count total weight and unit weight If the...

Страница 17: ...C key to clear and start again Example of a unit weight 32g 4 Press the ENTER key The unit weight 32g will have been entered If the unit weight entered is too light lo ut low unit weight will be disp...

Страница 18: ...12g previously entered as the unit weight of ID 123456 If there is no unit weight entered for the ID number you tried to recall no id will be displayed and you will be returned to step 3 6 You may now...

Страница 19: ...to zero the scale 2 Press the KEYBOARD TARE key The weight display will blink display is any tare weight previously entered 3 Use the 0 9 and 10 key pad to display the desired TARE weight q If you hit...

Страница 20: ...ey 3 The tare weight is cleared and the TARE ENTERED indicator will be turned off STABLE 888 554 F I 2AAWEIGHT kg 1234105678 0 615 23SAaaMPUW g 1234151671 11000456789012345 67 ZERO TOTAL M TARE ENTERE...

Страница 21: ...its ID number stays displayed and blinks 3 Use the 0 9 10 key pad to display the new ID number Example of ID number 123456 q If you hit the wrong key press the C key to clear and start again 4 Press...

Страница 22: ...ring All ID Memories at Once Clearing All ID Memories at Once 1 In the step 2 above press the TOTAL key id all will appear with all blinking 2 Press the ENTER key then all blinking will stop 3 Press t...

Страница 23: ...A A 5 Press the 0 key several times to place A A 6 Press the 3 DEF key to place D A A D 7 Press the TOTAL key twice to shift the cursor A A D _ 8 Press the 2 ABC key several times to place C A A D C...

Страница 24: ...pital Letters Lowercase Letters Numeric Characters _ 1 A B C a b c 2 D E F d e f 3 G H I g h i 4 J K L j k l 5 M N O m n o 6 P Q R S p q r s 7 T U V t u v 8 W X Y Z w x y z 9 0 Clear Space STORE UNIT...

Страница 25: ...r a unit weight and a tare weight by any method If necessary set the comparator limits and use the M accumulation 2 Go to step 2 of section 4 2 Store Unit Weight 4 2 Store Unit Weight 4 2 Store Unit W...

Страница 26: ...t Remember that you may only add the count data once the scale must return to near zero before it will let you add again To Erase the Last M Addition To Erase the Last M Addition To Erase the Last M A...

Страница 27: ...tions to the M memory is also shown 2 Press the TOTAL key again The display will return to normal 5 3 5 3 5 3 5 3 Clear Clear Clear Clearing the M Total ing the M Total ing the M Total ing the M Total...

Страница 28: ...Set To Set To Set the the the the Comparator Comparator Comparator Comparator q Start with the scale in standby mode display OFF 1 Press and hold the ZERO key then press the STANDBY OPERATE key relea...

Страница 29: ...porarily Changing Comparator Limits Temporarily q Set f 09 01 f 09 01 f 09 01 f 09 01 0 0 0 0 to use with this mode 1 In the step 1 above press the ENTER key then Upper limit value will blink 2 Change...

Страница 30: ...Using the Using the Using the Using the Key to Set Key to Set Key to Set Key to Set the the the the Time and Date Time and Date Time and Date Time and Date q Set the F Function f 09 01 f 09 01 f 09 0...

Страница 31: ...ation Procedure Using a Weight 8 1 Calibration Procedure Using a Weight The scale should have power connected at least one half hour to warm it up before starting the calibration procedure 1 Remove th...

Страница 32: ...f the weight is correct and try again 6 Press the CAL switch and re attach the calibration switch cover End of the calibration procedure ENTER 8Call00 F I Calibration Zero Cala0 Calibration weight kg...

Страница 33: ...ay flashes the gravity acceleration value stored in the scale 2 Use the 0 9 and 10 key pad to display the desired gravity acceleration value Example of the value 9 800 m s2 3 Press the ENTER key The s...

Страница 34: ...change the setting step 5 or move to the next F Function step 6 5 Use the 0 9 keys to change the setting The C key clears the input setting if you press the wrong 10 key pad and want to re enter If yo...

Страница 35: ...by sample only All other keys are disabled q Add Sample Request Override If the sample weight is too light and the scale asks to Add more sample pieces using this F Function the unit weight can be ent...

Страница 36: ...Contents The scale ID memory can contain unit weights with tare weights comparator limits and total count or just unit weights alone Item codes are always contained 000 000 000 000 ID memory contains...

Страница 37: ...weighing display division The factory setting may be different for some countries 0 0 0 0 1 5 d 1 1 1 1 1 100 d F 03 X M Accumulation Function F 03 X M Accumulation Function F 03 X M Accumulation Func...

Страница 38: ...g should be 0 F 05 X Comparator F 05 X Comparator F 05 X Comparator F 05 X Comparator q Comparator Mode 0 0 0 0 comparator off 1 1 1 1 compare all data 2 2 2 2 compare stable data 3 3 3 3 compare all...

Страница 39: ...7 X F 08 X Data Output f 06 X for standard RS 232C f 07 X for Ch 1 PORT 1 and f 08 X for Ch 2 PORT 2 q Data Out Mode 0 0 0 0 Key mode Data is sent by pressing the PRINT key command mode 1 1 1 1 Stream...

Страница 40: ...600 bps q Data Length and Parity 0 0 0 0 7 bits even parity 1 1 1 1 7 bits odd parity 2 2 2 2 8 bits non parity F 09 X F 09 X F 09 X F 09 X key q Operation mode for the key 0 0 0 0 Operating as a MODE...

Страница 41: ...etting for f 10 01 1 1 1 1 Enter ENTER Factory Setting for f 10 02 2 2 2 2 Tare TARE 3 3 3 3 Zero ZERO 4 4 4 4 Sample SAMPLE 5 5 5 5 Remote Scale REMOTE SCALE 6 6 6 6 Total TOTAL 7 7 7 7 M M 8 8 8 8 S...

Страница 42: ...e to reach the largest amount that you will be counting q If you want the most precise counting results for every different batch of the same items use ACAI every time you start counting the next batc...

Страница 43: ...ACAI will not recalculate unit weight until the ENTER key is pressed as long as it is at the proper time and the guidelines in the ACAI notes have been followed q The ACAI manual mode is controlled b...

Страница 44: ...Transmission system EIA RS 232C Transmission form Asynchronous bi directional half duplex Data format Baud rate 2400 4800 9600 bps Data 7 bits parity 1bit even or odd or 8 bits non parity Start bit 1...

Страница 45: ...08 03 08 03 2 2 2 2 This rate is same as the display update rate For f f f f 06 06 06 06 07 07 07 07 08 3 08 3 08 3 08 3 1 1 1 1 or 2 2 2 2 the interval between continuous data is approximately 1 6 se...

Страница 46: ...function and set f 06 07 08 2 to print pcs count data only or Weight data only Print Operations Settings Print Operations Settings Print Operations Settings Print Operations Settings Print By F Funct...

Страница 47: ...mand mode together with key mode or auto print mode set f 06 f 06 f 06 f 06 07 07 07 07 08 0 08 0 08 0 08 01 4 4 4 4 command mode only q Use a D sub 9 pin cable straight type to connect with a compute...

Страница 48: ...rn the display OFF ID Send the ID number and item code in use QT Send the pcs count data WT Send the weight data UW Send the unit weight in use AQ Send the total accumulated M memory count d t AN Send...

Страница 49: ...E2 Scale not ready error The scale is not in a state where a command could be expected E4 Too many characters error The command contains too many characters E6 Format error The command contains invali...

Страница 50: ...umulation number Command A N CR LF Reply A N 0 0 0 0 1 2 3 4 CR LF q Tare weight Command T R CR LF Reply T R 0 0 1 2 3 4 6 k g CR LF q Request the FC i scales to reply with the contents of ID memory C...

Страница 51: ...pecified ID memory Command M I 1 2 3 a b c d CR LF Reply AK ID Number Maximum 6 digit Item Code Maximum 12 digit The example above is stored as a b c d _ _ _ _ _ _ _ _ q Store the comparator limits in...

Страница 52: ...Reply F C 0 5 0 2 0 CR LF f 05 02 0 q Store the specified F Function setting value Command F C 0 5 0 3 1 2 3 4 CR LF Set 1234 as the Upper limit F Function number 4 digits Setting value Maximum 8 dig...

Страница 53: ...re that the battery switch on the battery pack is OFF position insert the battery pack firmly into the rear side of the scale 2 Tighten the lock screw on the battery pack 3 When desired turn the batte...

Страница 54: ...attery pack AC Adapter to scale Charge Scale operation ON or OFF Connected Connected Yes Operational ON or OFF Not connected Connected No Operational OFF Connected Not connected Yes Not operational ON...

Страница 55: ...er to 11 RS 232C SERIAL INTERFACE 11 RS 232C SERIAL INTERFACE 11 RS 232C SERIAL INTERFACE 11 RS 232C SERIAL INTERFACE Comparator Relay Output Circuit Comparator Relay Output Circuit Comparator Relay O...

Страница 56: ...to count q If f 01 03 f 01 03 f 01 03 f 01 03 is set at 1 1 1 1 then the scale will automatically switch to the remote scale after unit weight by sample pieces is registered by the main scale Pressing...

Страница 57: ...d add 0 to Ws until it is 5 digits 3 Calculate d Ns 10 000 4 Decide the minimum division d d 1 d 1 2 d 1 d 2 5 d 2 d 5 d 5 d 10 This should be changed to d 1 dividing Ns by 10 5 Now Ns x d and the res...

Страница 58: ...kg Calibrating the Remote Scale Calibrating the Remote Scale Calibrating the Remote Scale Calibrating the Remote Scale When a remote scale is newly connected set the capacity and calibrate the scale u...

Страница 59: ...section 8 1 Calibration Procedure Using a Weigh 8 1 Calibration Procedure Using a Weigh 8 1 Calibration Procedure Using a Weigh 8 1 Calibration Procedure Using a Weigh to calibrate the remote scale E...

Страница 60: ...Condensation Display 7 segment 5x7 dot VFD Display Update Approximately 10 times per second Interface RS 232C 1ch standard Maximum 3 ch with optional interface Power AC adapter or Optional Ni MH Batte...

Страница 61: ...9 806 m s2 Calcutta 9 788 m s2 Paris 9 809 m s2 Cape Town 9 796 m s2 Rio de Janeiro 9 788 m s2 Chicago 9 803 m s2 Rome 9 803 m s2 Copenhagen 9 815 m s2 San Francisco 9 800 m s2 Cyprus 9 797 m s2 Singa...

Страница 62: ...60 World map...

Страница 63: ......

Страница 64: ......

Отзывы: