86
9.1. Modbus
RTU
1. In the Connection Setting screen, touch the Connection Mode tab to open the screen shown below.
Select “Modbus” to set “Modbus/RTU.”
Note:
・
When the “Modbus” setting is changed, restart the checkweigher to confirm the change.
・
When “Modbus” is set to Modbus/RTU, the setting for the serial mode will be ignored.
Fig.72 Connection Setting screen (with Connection Mode tab selected)
2. Enter the slave address.
3. Touch the Connection tab to open the screen to set the serial communication.
Set “Data bits” to 8.
For details about serial communication settings, refer to “8.14. Connection.”
4. Connect to the serial interface to start communication.
9.2. Modbus
TCP
1. In the Connection Setting screen, touch the Connection Mode tab.
Select “Modbus” to set “Modbus/TCP.”
Note:
・
When the “Modbus” setting is changed, restart the checkweigher to confirm the change.
2. Enter the slave address.
3. Connect the LAN cable to start communication.