21
•
An excessive load is applied to the conveyor and the load cell is deformed.
•
An upward excessive load is applied to the load cell, for example, raising the checkweigher by holding the
conveyor, and the load cell is deformed.
If the weighing value is not zero even after the foreign substances are removed and zero adjustment is performed,
calibration using a weight is required.
When the load cell is deformed within the usable range, calibration using a weight will set the weighing value to zero.
If the weighing value is not zero even after calibration using a weight, replace the weighing conveyor unit
Note:
For details about calibration using a weight, refer to “5.1. Calibrating the Checkweigher Using a Weight.”
4.4.3.
Starting / Stopping the weighing operation
Press the START button on the display to move the conveyor to start a weighing operation.
Press the STOP button on the display to stop the conveyor to finish a weighing operation.