background image

 

2

1  Introduction 

This manual describes how the AD-1641 works and how to maximize 
performance. Please read this manual completely before using the AD-1641. 
This device conforms to FCC rules and CE mark EMC directives. 

1.1 

Features 

 

The AD-1641 is a data logger equipped with 5 sensors: air flow, temperature, 
humidity, barometric pressure and vibration. Air flow sensor part is independent 
from the instrument and can be installed to any desired location for 
measurement.

 

 

By connecting the output of the AD-1641 to the RS-232C of the insutrument, it 

is possible to record weighing data and environmental data sets so data can be 
saved without the computer.

 

 

The AD-1641 has a built-in clock. This allows the date and time to be stored 
along with the data.

 

 

A maximum of 10,000 data can be stored. 

 

The environmental data is stored in CSV format and can easily be used by 
software such as spreadsheet applications. 

 

The stored data can be read by a computer after the AD-1641 is recognized as 
USB memory so no special software is required. 

 

The AD-1641 can transmit data to programs in the computer (Ex: Excel, etc) 
using the USB interface. (Real time transmission mode) 

 

When connecting any combination of weighing instrument or computers, the 
power is supplied for the AD-1641 by them. In this case, AD-1641 batteries are 
not used. 

1.2  Caution During Use 

 

When operating this instrument, be sure to observe the following. 

 

Do not open the case to repair the AD-1641. Only authorized personnel can 
perfrm repairs. Attempting repairs yourself may cause damage to the AD-1641. 
and will void the warranty. 

  When the battery cover and temperature & humidity sensor unit are connected 

to the AD-1641 and the connectors are firmly seated in the water resistant 
connector covers, the AD-1641 is protected against light water exposure 
(equivalent to IP 65). Please note that the water resistance will not endure 
immersion in water or high pressure runnning water. 

Caution 

Caution 

Содержание AD-1641

Страница 1: ...AD 1641 Instruction Manual 1WMPD4003127 Air Flow Logger...

Страница 2: ...ormation or cautions to use the device correctly This manual is subject to change without any prior notice to improve the product No part of this manual may be photocopied reproduced or translated int...

Страница 3: ...ecord the Maximam Value of The Air Flow and Vibration PEAK HOLD 16 8 2 Connecting To The Weighing Instrument 18 8 2 1 The management of the weighing data 18 8 2 2 The Interval Measurement For The Weig...

Страница 4: ...such as spreadsheet applications The stored data can be read by a computer after the AD 1641 is recognized as USB memory so no special software is required The AD 1641 can transmit data to programs i...

Страница 5: ...AX KO3572 100 Din 7pin 1 m AX KO3573 10 A mini B type 1 8 m Two batteries for temporary use Size R6 AA This instruction manual Measurement monitor Replaceable Temperature humidity sensor unit Cable c...

Страница 6: ...7 2 setting the monitor display Note The battery level indicator is displayed when the battery is used It is not displayed when external power is used Temperature Barometric pressure Air flow Vibratio...

Страница 7: ...screen displays the two environmental data that were specified in the setting screen Refer to 7 2 setting the monitor display Temperature chart Relative humidity chart Barometric pressure chart Air F...

Страница 8: ...rts the interval measurement Cancels the setting operation Stops the interval recording SELECT Changes the current display ENTER Confirm settings recording UP DOWN Changes the parameter 1 When the int...

Страница 9: ...WER press ENTERkey In the case of battery drive When pressing and holding the ON OFF key the AD 1641 will turn on For inserting of batteries please refer to the 9 Replacement for batteries and Sensor...

Страница 10: ...speed values in 5 Air Flow Calibration before using the AD 1641 The air flow measurement battery life is approximately 20 hours Display turn off time can be changed in the time to display off POWER SA...

Страница 11: ...UNCTION from the setting screen to perform the calibration Press the SELECT key several times on the display screen to display the setting screen in the right figure Move the mark to FUNCTION using UP...

Страница 12: ...ss the ENTER key Step 3 Move the mark and set the 4 compartor function items JUDGMENT ITEM Select from AF Air Flow T1 Temperature RH Relative Humidity or BAR Barometric Pressure JUDGMENT TIME Select f...

Страница 13: ...T LO 0000 3 Note To use the Comparator function choose the JUDGEMENT TIME except for OFF Please set the upper limit value or lower limit value within the specifications Buzzer will sound from the AIR...

Страница 14: ...m or menu Step 4 Operations after finishing the management SELECT key Proceeds to the intended display Note Selectable items will change depending on operating conditions 7 1 INTERVAL TIME Specify the...

Страница 15: ...30 seconds 1 2 5 10 15 20 30 60 minutes PRIMARY DATA T1 Temperature RH Humidity BAR Barometric pressure AF Air Flow VIB Vibration WT Weighing data TEMP UNIT C Celsius F Fahrenheit RECORDING TYPE ONE...

Страница 16: ...ord the maximum value of the air flow and vibration Weighing value interval recording mode WEIGHING DATA Every Save at the time of receipt of the data Interval Save data for each interval time Refer t...

Страница 17: ...method of operation please see 8 3 Connecting To The computer Even when powered by USB cable from the AC adapter screen for selecting the function appears Please select EXT POWER at this time In this...

Страница 18: ...air flow and vibration the peak value during each interval time is held and recorded the peak value during each interval time is held and recorded When in the PeakHold mode P will be displayed next t...

Страница 19: ...ing spreed is fast POWER SAVE in the 7 4 FUNCTION is disabled 2 To avoid battery depletion connecting the AC adapter is recommended 3 When only the battery power is available please power OFF by holdi...

Страница 20: ...hing instrument continuously stream output at each interval Step 1 Select the Interval in 7 4 Function table Weighing value interval recording mode WEIGHING DATA WEIGHING DATA Interval The factory set...

Страница 21: ...te when removing the AD 1641 from the USB port of the computer 8 3 3 Transmitting Data To A Computer Real TimeTransmission Mode This method is used to transmit the environment and weighing data direct...

Страница 22: ...t the item REAL TIME and press the ENTER key to use the real time transmission mode Step3 Click on a position cell on the program EXCEL etc to receive data Step 4 Press the data output key Ex PRINT ke...

Страница 23: ...may leak and cause a malfunction The accessory batteries are for operation check and their life may be short The temperature humidity sensor unit is a consumable Replacement is approx 2 years each Wh...

Страница 24: ...th RS 232C please check our websites Data capacity Maximum 10 000 sets including data time Interval time 1 2 5 10 15 20 or 30 seconds 1 2 5 10 15 20 30 or 60 minutes Power supply Two alkaline batterie...

Страница 25: ...23 MEMO...

Страница 26: ...24 MEMO...

Страница 27: ......

Страница 28: ...1235 550420 Fax 44 1235 550485 A D INSTRUMENTS LIMITED German Scales Office Gro e Stra e 13 b 22926 Ahrensburg GERMANY Telephone 49 0 4102 459230 Fax 49 0 4102 459231 A D MERCURY PTY LTD 32 Dew Stree...

Отзывы: