18 

RS-232C 

cable 

  

8.2  Connecting To The Weighing Instrument 

  The AD-1641 saves the weighing data and environment data at the same time 

when receiving the weighing data.

 

8.2.1  The management of the weighing data 

Step 1  Connect the AD-1641 and A&D's weighing instrument using the provided 
 

 

RS-232C cable. 

 

Step 2  Press the data output key (Ex. PRINT key) 
 

of the weighing instrument to transmit   

 

data. The AD-1641 receives data and   

 

the indicator REC is shown for 1second. 

 
 
 
 
 
Step 3  Stored data is shown for 5 seconds in the measurement monitor. 

8.2.2  The Interval Measurement For The Weighing Instrument 

  By setting 7.4.Function table "Weighing value interval recording mode 

(WEIGHING DATA)" of the AD-1641 to "Interval", it is possible to save the 
weighing data sent from the weighing instrument continuously (stream output) 
at each interval.

 

 
 

 
 
 

Step 1  Select the "Interval" in 7.4.Function table "Weighing value interval recording 
 

mode" (WEIGHING DATA)   

 

WEIGHING DATA

Interval (The factory setting is "Every") 

Step 2  Connect the Weighing instrument that has been set in the stream output. 
 

In the case that the AD-1641 has received the weighing data, (WT) is 

 

displayed at lower left corner of the screen of the AD-1641, and weighing 

 

data is displayed

In this case, the weighing data is not saved. 

Step 3 

 

Pressing the START/STOP key, at the timing set by the interval time, starts 

saving weighing data.

 

Note 

 

A recording interval might deviate for a few seconds due to time lags in data 
reception. 

 

To set the display format of weighing data or to set the stream output of the 
weighing instrument, please refer to the "internal setting" "data format" of each 
instrument manual

 

When the AD-1641 body has received the weighing data, weighing data is 

 

displayed.

 

Weighing data 

Содержание AD-1641

Страница 1: ...AD 1641 Instruction Manual 1WMPD4003127 Air Flow Logger...

Страница 2: ...ormation or cautions to use the device correctly This manual is subject to change without any prior notice to improve the product No part of this manual may be photocopied reproduced or translated int...

Страница 3: ...ecord the Maximam Value of The Air Flow and Vibration PEAK HOLD 16 8 2 Connecting To The Weighing Instrument 18 8 2 1 The management of the weighing data 18 8 2 2 The Interval Measurement For The Weig...

Страница 4: ...such as spreadsheet applications The stored data can be read by a computer after the AD 1641 is recognized as USB memory so no special software is required The AD 1641 can transmit data to programs i...

Страница 5: ...AX KO3572 100 Din 7pin 1 m AX KO3573 10 A mini B type 1 8 m Two batteries for temporary use Size R6 AA This instruction manual Measurement monitor Replaceable Temperature humidity sensor unit Cable c...

Страница 6: ...7 2 setting the monitor display Note The battery level indicator is displayed when the battery is used It is not displayed when external power is used Temperature Barometric pressure Air flow Vibratio...

Страница 7: ...screen displays the two environmental data that were specified in the setting screen Refer to 7 2 setting the monitor display Temperature chart Relative humidity chart Barometric pressure chart Air F...

Страница 8: ...rts the interval measurement Cancels the setting operation Stops the interval recording SELECT Changes the current display ENTER Confirm settings recording UP DOWN Changes the parameter 1 When the int...

Страница 9: ...WER press ENTERkey In the case of battery drive When pressing and holding the ON OFF key the AD 1641 will turn on For inserting of batteries please refer to the 9 Replacement for batteries and Sensor...

Страница 10: ...speed values in 5 Air Flow Calibration before using the AD 1641 The air flow measurement battery life is approximately 20 hours Display turn off time can be changed in the time to display off POWER SA...

Страница 11: ...UNCTION from the setting screen to perform the calibration Press the SELECT key several times on the display screen to display the setting screen in the right figure Move the mark to FUNCTION using UP...

Страница 12: ...ss the ENTER key Step 3 Move the mark and set the 4 compartor function items JUDGMENT ITEM Select from AF Air Flow T1 Temperature RH Relative Humidity or BAR Barometric Pressure JUDGMENT TIME Select f...

Страница 13: ...T LO 0000 3 Note To use the Comparator function choose the JUDGEMENT TIME except for OFF Please set the upper limit value or lower limit value within the specifications Buzzer will sound from the AIR...

Страница 14: ...m or menu Step 4 Operations after finishing the management SELECT key Proceeds to the intended display Note Selectable items will change depending on operating conditions 7 1 INTERVAL TIME Specify the...

Страница 15: ...30 seconds 1 2 5 10 15 20 30 60 minutes PRIMARY DATA T1 Temperature RH Humidity BAR Barometric pressure AF Air Flow VIB Vibration WT Weighing data TEMP UNIT C Celsius F Fahrenheit RECORDING TYPE ONE...

Страница 16: ...ord the maximum value of the air flow and vibration Weighing value interval recording mode WEIGHING DATA Every Save at the time of receipt of the data Interval Save data for each interval time Refer t...

Страница 17: ...method of operation please see 8 3 Connecting To The computer Even when powered by USB cable from the AC adapter screen for selecting the function appears Please select EXT POWER at this time In this...

Страница 18: ...air flow and vibration the peak value during each interval time is held and recorded the peak value during each interval time is held and recorded When in the PeakHold mode P will be displayed next t...

Страница 19: ...ing spreed is fast POWER SAVE in the 7 4 FUNCTION is disabled 2 To avoid battery depletion connecting the AC adapter is recommended 3 When only the battery power is available please power OFF by holdi...

Страница 20: ...hing instrument continuously stream output at each interval Step 1 Select the Interval in 7 4 Function table Weighing value interval recording mode WEIGHING DATA WEIGHING DATA Interval The factory set...

Страница 21: ...te when removing the AD 1641 from the USB port of the computer 8 3 3 Transmitting Data To A Computer Real TimeTransmission Mode This method is used to transmit the environment and weighing data direct...

Страница 22: ...t the item REAL TIME and press the ENTER key to use the real time transmission mode Step3 Click on a position cell on the program EXCEL etc to receive data Step 4 Press the data output key Ex PRINT ke...

Страница 23: ...may leak and cause a malfunction The accessory batteries are for operation check and their life may be short The temperature humidity sensor unit is a consumable Replacement is approx 2 years each Wh...

Страница 24: ...th RS 232C please check our websites Data capacity Maximum 10 000 sets including data time Interval time 1 2 5 10 15 20 or 30 seconds 1 2 5 10 15 20 30 or 60 minutes Power supply Two alkaline batterie...

Страница 25: ...23 MEMO...

Страница 26: ...24 MEMO...

Страница 27: ......

Страница 28: ...1235 550420 Fax 44 1235 550485 A D INSTRUMENTS LIMITED German Scales Office Gro e Stra e 13 b 22926 Ahrensburg GERMANY Telephone 49 0 4102 459230 Fax 49 0 4102 459231 A D MERCURY PTY LTD 32 Dew Stree...

Отзывы: