27
3. THE D
AIL
Y OPERATING SPECIFICATION
ENGLISH
3.2. 7 Green ON, Red BLINKING
WARNING STATE.
AAVI
®
IonJet2000
is on and the warning state is activated because one of
the high voltage units is not operating correctly or its temperature is reaching the maximum limit.
Follow the situation and if the warning state does not go off despite cooling air temperature or
till the next morning then maintenance is needed.
AAVI
®
IonJet2000
purifier is still operating.
3.2. 8 Green ON, Red ON
Failure state.
AAVI
®
IonJet2000
is OFF and maintenance is needed. Failure state is activated if two
or more high voltage units are not operating correctly or their temperature is too high.
AAVI
®
IonJet2000
is automatically switched off and needs maintenance.
In the paragraph 4. COMMON qUESTIONS, FAULTS AND
SOLUTIONS there is some guidance for checking before
contacting authorized AAVI service.
3.3 AAVI
®
IONJET2000 AUTOMATION WEB UI
AAVI
®
IonJet2000
air purifier has an automation logic that controls and monitors its internal
state. The unit uses Siemens LOGO! 8 PLC logic, which provides a web server support meaning
that LOGO! 8 can be controlled by a service person via a PC browser.
More detailed settings are explained in Service Manual used by certified AAVI Technologies Ltd.
maintenance personnel.