background image

1

INSTALLATION 

GUIDE

ESX-200

DVB-S and DVB-S2 Satellite

Processor

design for TV

English

Содержание ESX-200

Страница 1: ...1 INSTALLATION GUIDE ESX 200 DVB S and DVB S2 Satellite Processor design for TV English ...

Страница 2: ...2 Contents 1 Introduction 2 Unpacking the unit 3 Connections and indications 4 Settings 5 About remultiplexing 6 Installation 7 Technical specification 8 Declaration of conformity 9 Glossary English ...

Страница 3: ... with NICAM audio IP control and management All hardware needed for upgrade with software options is available from the start See section 7 for more information ESX 200 can be upgraded for enhanced functionality and various formats for transmission and processing of digital TV content by upgrade of its firmware Software options will be available from A2B Electronics please ask us for the specifica...

Страница 4: ... items be missing when unpacking please contact our support service see page 3 for contact info English 2 Unpacking the unit Important information about power supply to ESX 200 To avoid problems with ESX 200 and or EPP 100 it is very important that both DC plugs on the EXM power cord are fitted into the EPP 100 i e each EXM unit needs to be fed from two DC outputs from the EPP 100 See picture to t...

Страница 5: ...nsert your Common Interface Conditional Access module into this slot Power on indicator Green light indicates that power is on Rx error Red light indicates that the receiver is not locked to the satellite transmission Access Tx error Red light indicates that the smart card is not authorised or analogue output signal is missing Ethernet port Ethernet for connection to a PC or handheld device with w...

Страница 6: ...omputer For example set your PC to IP address 192 168 0 19 and Net mask 255 255 255 0 3 Connections and indications continued A V out Connection for monitoring or to an RF modulator ASI in Input for ASI Asynchronous Serial Interface for high speed transport stream reception ASI out Output for ASI Asynchronous Serial Interface for high speed transport stream transmission DC in Connect a DC voltage ...

Страница 7: ...elect Use this IP adress and write 192 168 0 19 and select Net mask 255 255 255 0 Click OK and then click Close NOTE For PC with other Operating Systems OS than Windows please consult the Owners manual for your PC for IP Network settings 4 2 Connecting your PC to ESX 200 Connect the ESX 200 to a DC power supply EPP 100 See section 6 for installation Next connect your PC to the ESX 200 with a netwo...

Страница 8: ...ange the IP address and or the Netmask and or the Gateway This is an important function when you install two or more EXM units in a Head End and want to connect all units together through a switch or a router 4 Settings continued Current settings Contains information of current input and output signals if the tuner is locked to a signal serial number and firmware revision Entitlements Entitlements...

Страница 9: ...you don t use the same IP address in any ESX 200 unit To continue installation press Input 4 Settings continued 4 3 3 Input settings Select the modulation type you want to receive If you choose DVB S2 you also can select between QPSK 8PSK or 16 QAM Choose fixed or universal LNB Set the Polarisation Voltage FEC and 22 kHz tone you normally set to Auto if you have connect the ESX 200 to an Universal...

Страница 10: ... by selecting Country By selecting a specific country transmission standard and languages are automatically preset Audio language gives you the choosen language if there is more than one language ín the received signal Subtitling type subtitle priority and subtitle charset can be selected 4 Settings continued Finally enter the correct Symbol rate and click on Set and then the Transponder frequency...

Страница 11: ...you what the bitrate will be at the ASI output NOTE Refer to the table in page 16 about correct values Attenuation can be choosed between 0 to 31 dB The Frequency can be set in steps of 1kHz e g 306 167 MHz in all three output modes Analogue COFDM or QAM Click Set to save all settings 4 Settings continued QAM When selecting QAM DVB C output there are settings for Output channel E2 to E69 or Freque...

Страница 12: ...Settings continued 4 3 5 Service Management The Service management menu gives an overview of available services from satellite or the ASI input if enabled Remultiplexing remuxing is possible after downloading an appropriate SW option To build your own MUX you combine several incoming services These can be received either from the tuner or from the ASI in Under the Digital output section in this me...

Страница 13: ...nds following Network ID ranges DVB S 0 to 8191 0 should be avoided DVB T 8193 to 13568 DVB C 40961 to 65281 ComHem in Sweden use 41001 and up The ESX 200 is designed to perform remultiplexing automatically of both audio and video streams as well as full remultiplexing and regeneration of PSI SI data The advantage for you as a user is lower risk of failure and that the process is much less time co...

Страница 14: ...s with the uploaded software Please refer to the installation information for each specific SW 4 3 5 Service management cont For setting the LCN Logical Channel Number you click on the sign under the column named Options In the box under the label Logical channel number you write the number you want for the service you have chosen and click the Set button Note LCN is not supported in all DVB recei...

Страница 15: ...to set UDP RTP values for Port and Address e g IP address 239 192 0 10 and Port 1234 In the Bitrate box you can choose bitrate for the IPTV TS out The maximum value is 55Mb s Click Set bitrate to save settings Click Start to start IPTV streaming on the output RJ 45 connector To check the IPTV out signal use VLC Player or similar We recommend you to visit our website www a2b se for updated info abo...

Страница 16: ...te fluctuations from statistical multiplexing we recommend that you only use 85 of the maximum available bit rate English Output signal Modulation Baudrate BW Max bitrate Mb s 85 COFDM 64QAM 8 MHz 31 67 26 92 COFDM 64QAM 7 MHz 27 71 23 55 COFDM 64QAM 6 MHz 23 75 20 19 QAM 16QAM 6 875 Mbaud s 25 34 21 54 QAM 32QAM 6 875 Mbaud s 31 68 26 93 QAM 64QAM 6 875 Mbaud s 38 01 32 31 QAM 128QAM 6 875 Mbaud ...

Страница 17: ... the LNB to the LNB input and another one from the RF output to the cable TV network Connect a power supply and make all necessary settings as described in section 4 Note Important information in page 4 about connecting the DC cable EPP 100 power supply100W 11 outputs Wall mount plate DC cable for ESX 200 English Installation in a base unit with 5 EXM modules and common power supply Accessories EB...

Страница 18: ...and unit 3 has SW option for enhanced functionality with ASI in and COFDM out VSB RF is default modulation format NOTE Unit 2 and unit 3 has SW option for added functionality as ASI in and QAM out VSB RF is default modulation format ESX 200 1 ESX 200 2 ESX 200 3 ASI ASI VSB RF out VSB RF out COFDM out ESX 200 1 ESX 200 2 ESX 200 3 ASI ASI VSB RF out VSB RF out QAM out ...

Страница 19: ...HCP with possibility for remote management over VPN connection between office and Head end NOTE If you have questions about how to set up the VPN connection ask your network administrator for detailed information ESX 200 connected through a switch with DHCP VPN connection ...

Страница 20: ... S EN 300 421 DVB S2 EN 302 307 RF Modulation analogue Standards B G I D K L M N Sound Mono NICAM stereo or A2 A2 stereo Modulation video VSB AM neg or pos Modulation mono Audio FM or AM Output frequency 47 862 MHz Output level 110 dBuV 47 470 MHz 105 dBuV 470 862 MHz S N weighted 57 dB C N broadband 70 dB NICAM standards NICAM 728 EN 300 163 Power ratio B G 20dB Vision NICAM carrier I 24dB D K 24...

Страница 21: ...I SI tables to avoid clashes in the output multiplexes Simple structure for setting input output and processing parameters Each ESX 200 contains an embedded web server Standard web browsers Internet Explorer Mozilla Firefox etc are supported Graphical User Interface GUI ASI bit rate 270 Mbit s Max payload bitrates Input bit rate 55 Mbit s Output bit rate 55 Mbit s PCR restamping Yes PSI SI managem...

Страница 22: ...22 8 Declaration of Conformity The document for Declaration of Conformity you will find at www a2b se Further information at www a2b se English ...

Страница 23: ...on standard for digital TV in terrestrial networks Remultiplexing Way of recombining services from different multiplexes DHCP Dynamic Host Configuration Protocol is a protocol used by networked devices clients to obtain the parameters necessary for operation in an Internet Protocol network This protocol reduces system administration workload allowing devices to be added to the network with little ...

Страница 24: ...onics AB Södra Allén 23 25 591 37 Motala P O Box 14 591 21 Motala SWEDEN Phone 46 141 229100 Fax 46 141 229101 E mail market a2b se To view our full line of Professional E series Products visit our Web site 651200 01 rev 1 1B ...

Отзывы: