9. Specification

Model 

a-TroniX Jump starter Booster 12/24V 10000/5000A

Article number 

9885377

Operating Voltage (V) 

12/24

Continuous Current (A) 

2000/1000

Start max. Amperage (A) 

5000/2500

Peak Ampere (A) 

10000/5000

Cable Length (cm) 

160

Cable Size (mm

2

) 25

Max. Charge Voltage (V) 

14,5

Clamp Output (A) 

1000

Battery type 

2 Pack Lithium LiFePo4

Reverse Polarity Protection 

x

Short Circuit Protection 

x

Overvoltage Protection 

x

Size (mm)  

350 x 240 x 140

Net Weight (kg) 

5

Содержание 9885377

Страница 1: ...BOOSTER Instruction Manual a TroniX Jump starter Booster 12 24V 10000 5000A Article Article number a TroniX Jump starter Booster 12 24V 10000 5000A 9885377 09 2021 Page 1 ...

Страница 2: ... ideal emergency helper Read carefully before use Read this manual carefully before installation It contains important regulations and instructions for the use of this product and provides technical support for the operator of the unit All rights reserved AKKU SYS Akkumulator und Batterietechnik Nord GmbH cannot be held responsible for any inaccuracies or inappropriate information in this instruct...

Страница 3: ...y instructions 5 2 1 Risk of explosive gases 5 2 2 Risk of electric shock or fire 5 2 3 Personal Precautions 6 2 4 Use Precautions 7 3 How to charge the emergency starter 8 4 How to use the emergency starter 9 5 Override function 10 6 Using the Emergency Starter as a 12V or 24V Memory Saver 12 7 Error warnings 13 8 Protecting the environment 14 9 Specification 15 ...

Страница 4: ...s notes or tips Failure to take precautionary measures may result in damage to the product and or its functions or to an object in its vicinity ENVIRONMENT Indicates recycling information Indicates assemblies or parts that must be disposed of properly Do not dispose of them in the household waste Defective accumulators must be disposed of in an environmentally friendly manner Do not throw them in ...

Страница 5: ...y of a lead acid battery is dangerous Batteries generate explosive gases during normal operation It is important that you follow these instructions each time you use the unit To reduce the risk of battery explosion follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of a battery Review cautionary markings...

Страница 6: ...trical part that may cause an explosion Do not permit the internal batteries of the unit to freeze Never charge a frozen battery To prevent sparking NEVER allow clamps to touch together or contact the same piece of metal Consider having someone nearby to come to your aid when you work near a lead acid battery Have plenty of fresh water soap and baking soda nearby for use in case battery acid conta...

Страница 7: ...electrical system can cause explosions and damage the vehicle product and people Before starting up switch off the vehicle lights and all other accessories CAUTION Never place the terminals of the two battery clips red positive and black negative in contact with one another CAUTION Never switch polarity Always connect the output conductor with a red battery clip to the positive pole of the battery...

Страница 8: ...ter red battery at 30 yellow battery at 60 green battery at 100 If the voltmeter gauge does not reach green charge the battery of the Emergency Starter Insert the plug of the 230V charger into the charging socket located on the front of the Emergency Starter Insert the charger into the socket of the 230V domestic supply If the Emergency Starter is not in use recharge it at least every 3 months for...

Страница 9: ...e of the battery and the output conductor with a black battery clip to the vehicle s earth ground CAUTION Inverting polarity can cause explosions damage the vehicle product and people CAUTION If the LED RED REVERSE is set on the polarity has been reversed Disconnect the battery clips from the vehicle and connect them correctly CAUTION Check that the cables of the Emergency Starter are far away fro...

Страница 10: ...ongs its life Once you reach your destination remember to connect your battery to a battery charger for vehicles to restore it to maximum efficiency 5 Override function This mode is recommended when a vehicle with completely or extremely flat absent or cut off battery needs to be started CAUTION SOME PROTECTION ARE NOT ACTIVE TAKE CARE Always wear safety goggles and keep your face away from the ba...

Страница 11: ...clips from the vehicle and connect them correctly CAUTION Check that the cables of the Emergency Starter are far away from fans from moving parts and from the fuel conduit Once the vehicle has been started up emergency starter automatically turns off after 30 seconds Otherwise press START STOP button to turn off the emergency starter Disconnect the output conductor with the black battery clip from...

Страница 12: ... Clips are connected the Err8 error will showed Now PRESS START STOP the display show SET Select the correct tension 12V or 24V using the selection button Set MEMORY SAVER function Now PRESS START STOP for 3 seconds until ON blink on the display Release the button and the display show MEMO Connect the Battery Clips and perform the Memory Saver activities Identify the pole corresponding to the eart...

Страница 13: ...k battery clip from the earth of the vehicle and replace output conductor with the black battery clip in its housing Disconnect the output conductor with the red battery clip from the positive terminal of the battery and return it immediately to its seat CAUTION Always recharge the Emergency Starter after each time that it is used 7 Error warnings Error Description Err 1 Reverse Short circuit dama...

Страница 14: ... Do not throw them in the household waste Take advantage of the certified and professional recycling service offered by our AKKU SYS team For further information please contact us on the Hotline 49 4101 376760 at info akkusys de or use the QR code Do not short circuit the battery terminals If possible operate the unit so that the battery is fully discharged before disposal The packaging is recycla...

Страница 15: ...9885377 Operating Voltage V 12 24 Continuous Current A 2000 1000 Start max Amperage A 5000 2500 Peak Ampere A 10000 5000 Cable Length cm 160 Cable Size mm2 25 Max Charge Voltage V 14 5 Clamp Output A 1000 Battery type 2 Pack Lithium LiFePo4 Reverse Polarity Protection x Short Circuit Protection x Overvoltage Protection x Size mm 350 x 240 x 140 Net Weight kg 5 ...

Страница 16: ...nik Nord GmbH Verbindungsweg 23 25469 Halstenbek Hamburg GERMANY Tel 49 4101 3 76 76 0 Fax 49 4101 3 76 76 66 info akkusys de www akkusys de Other manufacturers and product ranges you will find in our AKKU SYS complete catalogue Go to our catalogue ...

Отзывы: