INS

TALLA

TION

  Residen  al Hybrid Electric Heat Pump Water Heater Use and Care Guide 

  17

INSTALLATION

Post Installa  on Review

1

Understand how to use the 
User Interface Module to set 
the various modes and 

func  ons.

2

Hybrid Mode is the recom-
mended Opera  ng Mode. 
Understand the various 

Opera  ng Modes and which mode 
may be best, based on ambient 
temperature and hot water demands.

3

Understand the importance of 
rou  ne inspec  on/ mainte-
nance of the condensate drain 

pan and lines. This is to prevent any 
possible drain line blockage resul  ng in 
the condensate drain pan over

fl

 owing.

NOTE:

 If water is coming from the 

over

fl

 ow slot of the condensate drain 

access cover, this indicated that both 
condensate drain lines may be blocked 
and immediate ac  on is required.

Overflow Slot

Drain Access Cover

Primary Drain

Secondary Drain

Figure 25 -

Condensate Drain Access 

Cover

4

To maintain op  mal opera-

 on, check, remove and clean 

the air 

fi

 lter as needed.

5

The Installa  on Instruc  ons 
and Use and Care Guide 
should be kept with the water 

heater for reference. 

Water Temperature Ad-
justment

The water temperature can be 
adjusted from 95°F / 35°C to 140°F / 
60°C. Use the Up and Down Bu  ons  

 on the front panel 

to set the desired temperature (see 

fi

 gure 26 on page 19). The se   ng 

temperature will blink on the display, 
press Mode/Enter bu  on to con

fi

 rm.

The water temperature can be 
adjusted quickly by pressing the 
“Temperature Up” bu  on and holding 
for three seconds.

NOTE:

 Before a  emp  ng to adjust 

the thermostat, read the “Water 
Temperature Regula  on” sec  on. If 
the instruc  ons are not clear, contact 
a quali

fi

 ed person. 

NOTE:

 For increased water demand, 

switching (temporarily) to Hybrid 
Mode or Electric Mode will decrease 
the recovery/re-heat   me. Be sure to 
switch back to the desired opera  onal 
mode when 

fi

 nished.

Opera  ng Mode De-
scrip  ons

The opera  ng modes can be changed 
sequen  ally by pressing the Mode/
Enter bu  on (Figure 26, page 19). The 
Opera  on Mode Indica  on Light will 
turn on when the relevant mode is 
selected. 
This unit is equipped with technology 
that senses the hot water demand 
from the unit. While in E

  ciency or 

Hybrid mode, during normal usage, 
the unit will operate the heat pump 
for maximum e

  ciency. In   mes that 

the water usage is above normal, this 

unit has the ability to use one element 
(upper or lower) and the heat pump 
simultaneously to help improve 
recovery. This transi  on is seamless 
and will go unno  ced.

Efficiency Mode - 

Provides the highest efficiency and 
lowest cost operation by using only 
the heat pump for heating. Recovery 
time and efficiency will vary with 
ambient temperature and relative 
humidity. Efficiency will be greatest, 
and recovery quickest, when both 
are high. At lower temperatures and 
relative humidity levels, efficiency 
will be lower and recovery will take 
longer. Heat pump operation is 
allowed between 45°F / 7.2°C  to 
120°F / 48.8°C ambient temperature. 
At ambient temperatures lower 
than 45°F / 7.2°C and greater than 
120°F / 48.8°C, the heat pump will 
not operate. Similarly, if the water 
temperature in the tank is less than 
59°F / 15°C, the heat pump will 
not operate. The unit will operate 
in electric mode until ambient and 
water temperatures return to the safe 
operating range of the heat pump.

Содержание Voltex FHPT-50

Страница 1: ...sure you can safely and properly do any of this work yourself Call our Technical Assistance Hotline at 1 800 527 1953 We can help you with installation operations troubleshooting or maintenance Before...

Страница 2: ...Drain Pan Discharge Pipe Do Not Cap or Plug Temperature and Pressure Relief Valve Drain Cold Inlet Hot Outlet Shut off Valve Hot Air Filter User Interface Module UIM Upper Element and ECO Condensate D...

Страница 3: ...ult in death or serious injury CAUTION CAUTION indicates a hazardous situa on that if not avoided could result in minor or moderate injury NOTICE NOTICE indicates prac ces not related to physical inju...

Страница 4: ...the risk of scalding Higher temperatures increase the risk of scalding but even at 120 F hot water can scald If you choose a higher temperature Thermostatic Mixing Valves located at each point of use...

Страница 5: ...heater is subjected to flood conditions or the thermostat s have been submerged in water the entire water heater must be replaced Make electrical connections prop erly according to the instructions o...

Страница 6: ...thori es may have similar requirements or other codes applicable to the installa on of this water heater 3 Before you start be sure you have and know how to use the following tools and supplies Plumbi...

Страница 7: ...d water supply line and adjust the water pressure control to between 50 and 60 psi If your home does not have a Pressure Reducing Valve install a PRV on the home s main water supply line and set it to...

Страница 8: ...s require and we recom mend installing the water heater in a drain pan that is piped to an ade quate drain The drain pan must be at least two inches wider than the diameter of the water heater Install...

Страница 9: ...on of water the tank will eventually leak To minimize property damage from leaks inspect and maintain your water heater in accor dance with this manual s instruc ons Inspect the drain pan pipes and su...

Страница 10: ...hose in a drain outside or a bucket Note that sediment in the bo om of the tank may clog the valve and prevent it from draining If you can t get the tank to drain contact a qualified person 7 Turn the...

Страница 11: ...con densate drainage An unlevel unit may lead to condensate draining inproperly and resulting in property damage DO NOT CONNECT ELECTRICAL WIRING UNTIL YOU ARE INSTRUCTED TO DO SO NOTICE Connec ng ele...

Страница 12: ...mp in the event the con densate pump fails or the float switch in the pump ac vates see step 5 on page 11 1 Using 3 4 PVC piping a 90 elbow that is 3 4 slip 3 4 NPT and an approved sealant none suppli...

Страница 13: ...here hot water will be used WARNING Even if the water heater s thermostat s are set to a rela vely low temperature hot water can scald Install Thermosta c Mixing Valves at each point of use to reduce...

Страница 14: ...n tains an outlet connec on J tube that has an orienta on mark that must line up with arrow in a 12 o clock posi on 3 Connect the hot water supply using 3 4 inch NPT to the hot water outlet Follow the...

Страница 15: ...Ensure that wire sizes type and connec ons comply with all applicable local codes In the absence of local codes follow NFPA 70 and the current edi on of the Na onal Electric Code NEC Figure 22 Connec...

Страница 16: ...1 The water heater s tempera ture se ng has been factory set to approximately 120 F to reduce the risk of scald injury You may wish to set a higher temperature to provide hot water for automa c dishwa...

Страница 17: ...r Temperature Regula on sec on If the instruc ons are not clear contact a qualified person NOTE For increased water demand switching temporarily to Hybrid Mode or Electric Mode will decrease the recov...

Страница 18: ...nge 1 to 99 days The vacation timer will blink on the display press the Mode Enter button to confirm the vacation timer To deactivate Vacation Mode press the Mode Enter button to switch to the desired...

Страница 19: ...drain lines then a condensate pump must be used DO NOT discharge the condensate drain lines into the metal drain pan In a closed system use a thermal expansion tank See Closed System Thermal Expansion...

Страница 20: ...lacing the Heating Element section on page 27 SF The air filter is dirty 1 Turn off power at the circuit breaker fuse box 2 Clean the air filter See Air Filter Maintenance section on page 30 ECF The h...

Страница 21: ...sists proceed to the next step 3 Check control wire connections to condensate pump If error persists proceed to the next step 4 Replace accessory condensate pump If error persists contact a qualified...

Страница 22: ...e see Adjusting the Temperature section on page 16 2 Clean air filter 3 Change to different mode or modify usage patterns For example if in Efficiency Mode switch to Hybrid Mode 4 Ensure the cold conn...

Страница 23: ...xpansion tank 3 Non functioning Temperature Pressure Relief Valve 4 Debris under valve seat 1 Check water supply inlet pressure If higher than 80 PSIG install a pressure reducing valve 50 60 PSIG is t...

Страница 24: ...Turn the circuit breaker back on or install the fuses and check the power on both incoming power wires using a non contact circuit tester Turn the power off and replace the cover on the electrical jun...

Страница 25: ...e to the tank overhea ng WARNING Do not cap or plug the T P relief valve or discharge pipe and do not operate the water heater without a func oning T P Relief Valve this could cause an explosion Water...

Страница 26: ...al water u lity If the low pres sure is only on the hot water side the primary causes of this are Melted heat traps or dip tube Solder ing copper pipes while they are con nected to the water heater ca...

Страница 27: ...k the hot and cold connec ons and make sure your homes hot water pipe is connected to the hot wa ter outlet on the water heater Usually reversed connec ons are found soon a er the installa on of a new...

Страница 28: ...ter remove and check the heating elements whenever you drain the tank If you have heavy lime depos its on heating elements you will need to replace them more often Sediment may form large masses that...

Страница 29: ...out Once you are certain the tank is completely full of water close the hot water faucet 10 Restore power to the water heater It may take two hours for the tank to heat up Replacing the Hea ng Element...

Страница 30: ...ep 10 in the Installa on sec on 10 Refill the tank by opening the cold water supply valve Make sure a hot water faucet is open and the drain valve is closed Allow the hot water to run full for at leas...

Страница 31: ...ECO fits ghtly against the tank 9 A ach the wires following the wiring diagram on the water heater s label Make sure all wire connec ons are ght 10 Replace the plas c element ECO cover insula on and a...

Страница 32: ...t the circuit breaker fuse box 1 Take the two tabs on the air filter and remove slide it from the top cover of the unit 2 If you are replacing the filter skip to step four To clean the filter use a va...

Страница 33: ...Coil Discharge Temperature Sensor Assembly 13 Upper Lower Tank Temperature Sensor Assembly 14 Fan Shroud 15 Condensate Drain Access Cover 16 Electronic Expansion Valve Coil 17 Run Capacitor 18 Relay K...

Страница 34: ...NOTES 34 Residen al Hybrid Electric Heat Pump Water Heater Use and Care Guide NOTES...

Страница 35: ...NOTES Residen al Hybrid Electric Heat Pump Water Heater Use and Care Guide 35 NOTES...

Страница 36: ...Teflon is a registered trademark of E I Du Pont De Nemours and Company 2015 A O Smith Corporation All Rights Reserved...

Отзывы: