background image

INS

TALLA

TION

  Residen  al Hybrid Electric Heat Pump Water Heater Use and Care Guide 

  13

INSTALLATION

3

Terminate the discharge pipe 
a maximum of six inches 
above a 

fl

 oor drain or outside 

the building. Do not drain the dis-
charge pipe into the drain pan; instead 
pipe it separately to an adequate 
drain. In cold climates, terminate the 
discharge pipe inside the building to an 
adequate drain. Outside drains could 
freeze and obstruct the drain line. 
Protect the drain from freezing. 

DISCHARGE 
PIPE

DRAIN
PIPE

Figure 17 -

The end of the T&P Relief Valve 

discharge pipe must stop no more than six 
inches above a floor drain or outside.

4

Do not place any valve or 
other restric  on between the 
tank and T&P Relief Valve. Do 

not cap, block, plug, or insert any valve 
between the T&P Relief Valve and the 
end of the discharge pipe. Do not 
insert or install any reducer in the 
discharge pipe.

Step 8:

Install shuto

  and

mixing valves

1

If one is not already installed, 
install a manual shuto

  valve 

in the cold water line that 

supplies the water heater. Install the 
shuto

  valve near the water heater so 

that it is readily accessible. Only use 
valves that are compa  ble with 

potable water. Use only full-

fl

 ow ball 

or gate valves. Other types of valves 
may cause excessive restric  on to the 
water 

fl

 ow. 

2

Install a Thermosta  c Mixing 
Valve at each point-of-use (for 
example, kitchen sink, 

bathroom sink, bath, shower).  Consult 
the valve manufacturer’s instruc  ons 
or a quali

fi

 ed person.

Figure 18 -

Install Thermostatic Mixing 

Valves at each point where hot water will 
be used.

 WARNING! Even if the water 

heater’s thermostat(s) are set to a 
rela  vely low temperature, hot water 
can scald. Install Thermosta  c Mixing 
Valves at each point-of-use to reduce 
the risk of scalding. 

3

For water heaters that are fed 
by a solar water hea  ng 
system (or any other pre-heat-

ing system), always install a Thermo-
sta  c Mixing Valve or other tempera-
ture limi  ng device in the inlet water 
supply line to limit water supply inlet 
temperature to 120°F. Solar water 
hea  ng systems can supply water with 
temperatures exceeding 170°F and may 
result in water heater malfunc  on.

 WARNING! Hot water provided by 

solar hea  ng systems can cause severe 
burns instantly, resul  ng in severe 
injury or death (

page 4

).

Step 9:

Connect the water
supply

1

Determine the type of water 
pipes in your home. Most 
homes use copper water pipes, 

but some use CPVC or cross-linked 
polyethylene (PEX). Use 

fi

    ngs 

appropriate for the type of pipe in your 
home. Do not use iron or PVC pipe – 
they are not suitable for potable water. 

2

Connect the cold water supply 
using 3/4 inch Na  onal Pipe 
Thread “NPT” to the blue cold 

water connec  on near the bo  om of 
the heater. 

For ease of removing the water heater 
for service or replacement, connect 
the water pipes with a coupling 
called a union. We recommend using 
a dielectric-type union (available at 
your local plumbing supplier   ). Dielec-
tric unions can help prevent corro-
sion caused by tiny electric currents 
common in copper water pipes and 
can help extend the life of the water 
heater. 

Recircula  ng Loop

In order to optimize efficiency of this 
unit, it is not recommended for use 
with a recirculation loop. Using this in 
a recirculation loop may cause the unit 
to run excessively.

Содержание Voltex FHPT-50

Страница 1: ...sure you can safely and properly do any of this work yourself Call our Technical Assistance Hotline at 1 800 527 1953 We can help you with installation operations troubleshooting or maintenance Before...

Страница 2: ...Drain Pan Discharge Pipe Do Not Cap or Plug Temperature and Pressure Relief Valve Drain Cold Inlet Hot Outlet Shut off Valve Hot Air Filter User Interface Module UIM Upper Element and ECO Condensate D...

Страница 3: ...ult in death or serious injury CAUTION CAUTION indicates a hazardous situa on that if not avoided could result in minor or moderate injury NOTICE NOTICE indicates prac ces not related to physical inju...

Страница 4: ...the risk of scalding Higher temperatures increase the risk of scalding but even at 120 F hot water can scald If you choose a higher temperature Thermostatic Mixing Valves located at each point of use...

Страница 5: ...heater is subjected to flood conditions or the thermostat s have been submerged in water the entire water heater must be replaced Make electrical connections prop erly according to the instructions o...

Страница 6: ...thori es may have similar requirements or other codes applicable to the installa on of this water heater 3 Before you start be sure you have and know how to use the following tools and supplies Plumbi...

Страница 7: ...d water supply line and adjust the water pressure control to between 50 and 60 psi If your home does not have a Pressure Reducing Valve install a PRV on the home s main water supply line and set it to...

Страница 8: ...s require and we recom mend installing the water heater in a drain pan that is piped to an ade quate drain The drain pan must be at least two inches wider than the diameter of the water heater Install...

Страница 9: ...on of water the tank will eventually leak To minimize property damage from leaks inspect and maintain your water heater in accor dance with this manual s instruc ons Inspect the drain pan pipes and su...

Страница 10: ...hose in a drain outside or a bucket Note that sediment in the bo om of the tank may clog the valve and prevent it from draining If you can t get the tank to drain contact a qualified person 7 Turn the...

Страница 11: ...con densate drainage An unlevel unit may lead to condensate draining inproperly and resulting in property damage DO NOT CONNECT ELECTRICAL WIRING UNTIL YOU ARE INSTRUCTED TO DO SO NOTICE Connec ng ele...

Страница 12: ...mp in the event the con densate pump fails or the float switch in the pump ac vates see step 5 on page 11 1 Using 3 4 PVC piping a 90 elbow that is 3 4 slip 3 4 NPT and an approved sealant none suppli...

Страница 13: ...here hot water will be used WARNING Even if the water heater s thermostat s are set to a rela vely low temperature hot water can scald Install Thermosta c Mixing Valves at each point of use to reduce...

Страница 14: ...n tains an outlet connec on J tube that has an orienta on mark that must line up with arrow in a 12 o clock posi on 3 Connect the hot water supply using 3 4 inch NPT to the hot water outlet Follow the...

Страница 15: ...Ensure that wire sizes type and connec ons comply with all applicable local codes In the absence of local codes follow NFPA 70 and the current edi on of the Na onal Electric Code NEC Figure 22 Connec...

Страница 16: ...1 The water heater s tempera ture se ng has been factory set to approximately 120 F to reduce the risk of scald injury You may wish to set a higher temperature to provide hot water for automa c dishwa...

Страница 17: ...r Temperature Regula on sec on If the instruc ons are not clear contact a qualified person NOTE For increased water demand switching temporarily to Hybrid Mode or Electric Mode will decrease the recov...

Страница 18: ...nge 1 to 99 days The vacation timer will blink on the display press the Mode Enter button to confirm the vacation timer To deactivate Vacation Mode press the Mode Enter button to switch to the desired...

Страница 19: ...drain lines then a condensate pump must be used DO NOT discharge the condensate drain lines into the metal drain pan In a closed system use a thermal expansion tank See Closed System Thermal Expansion...

Страница 20: ...lacing the Heating Element section on page 27 SF The air filter is dirty 1 Turn off power at the circuit breaker fuse box 2 Clean the air filter See Air Filter Maintenance section on page 30 ECF The h...

Страница 21: ...sists proceed to the next step 3 Check control wire connections to condensate pump If error persists proceed to the next step 4 Replace accessory condensate pump If error persists contact a qualified...

Страница 22: ...e see Adjusting the Temperature section on page 16 2 Clean air filter 3 Change to different mode or modify usage patterns For example if in Efficiency Mode switch to Hybrid Mode 4 Ensure the cold conn...

Страница 23: ...xpansion tank 3 Non functioning Temperature Pressure Relief Valve 4 Debris under valve seat 1 Check water supply inlet pressure If higher than 80 PSIG install a pressure reducing valve 50 60 PSIG is t...

Страница 24: ...Turn the circuit breaker back on or install the fuses and check the power on both incoming power wires using a non contact circuit tester Turn the power off and replace the cover on the electrical jun...

Страница 25: ...e to the tank overhea ng WARNING Do not cap or plug the T P relief valve or discharge pipe and do not operate the water heater without a func oning T P Relief Valve this could cause an explosion Water...

Страница 26: ...al water u lity If the low pres sure is only on the hot water side the primary causes of this are Melted heat traps or dip tube Solder ing copper pipes while they are con nected to the water heater ca...

Страница 27: ...k the hot and cold connec ons and make sure your homes hot water pipe is connected to the hot wa ter outlet on the water heater Usually reversed connec ons are found soon a er the installa on of a new...

Страница 28: ...ter remove and check the heating elements whenever you drain the tank If you have heavy lime depos its on heating elements you will need to replace them more often Sediment may form large masses that...

Страница 29: ...out Once you are certain the tank is completely full of water close the hot water faucet 10 Restore power to the water heater It may take two hours for the tank to heat up Replacing the Hea ng Element...

Страница 30: ...ep 10 in the Installa on sec on 10 Refill the tank by opening the cold water supply valve Make sure a hot water faucet is open and the drain valve is closed Allow the hot water to run full for at leas...

Страница 31: ...ECO fits ghtly against the tank 9 A ach the wires following the wiring diagram on the water heater s label Make sure all wire connec ons are ght 10 Replace the plas c element ECO cover insula on and a...

Страница 32: ...t the circuit breaker fuse box 1 Take the two tabs on the air filter and remove slide it from the top cover of the unit 2 If you are replacing the filter skip to step four To clean the filter use a va...

Страница 33: ...Coil Discharge Temperature Sensor Assembly 13 Upper Lower Tank Temperature Sensor Assembly 14 Fan Shroud 15 Condensate Drain Access Cover 16 Electronic Expansion Valve Coil 17 Run Capacitor 18 Relay K...

Страница 34: ...NOTES 34 Residen al Hybrid Electric Heat Pump Water Heater Use and Care Guide NOTES...

Страница 35: ...NOTES Residen al Hybrid Electric Heat Pump Water Heater Use and Care Guide 35 NOTES...

Страница 36: ...Teflon is a registered trademark of E I Du Pont De Nemours and Company 2015 A O Smith Corporation All Rights Reserved...

Отзывы: