TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

 

A Vent 

Pipe

 B Draft 

hood 

  C  Anode (Not Shown)
  D  Hot Water Outlet
 E Insulation
  F  Gas Supply Piping
  G  Manual Gas Shut-off Valve
  H  Ground Joint Union
  I 

Drip Leg (Sediment Trap)

 J Inner 

Door

 K Outer 

door

 L Union
  M   Inlet Water Shut-off Valve
  N  Cold Water Inlet
  O  Inlet Dip Tube
  P  Temperature & Pressure Relief Valve 
  Q   Rating Plate
 R Flue 

Baf

fl

 e

  S  Gas Control Valve/Thermostat
 T Drain 

Valve

  U   Main Burner
 V 

 Flue

  W   Suitable Metal Drain Pan
 X Control 

Display

  Y  Power Supply Transformer

           (

Shown detached from Heater

)

 YY 

Pressure 

Switch

           (

Shown detached from Heater

)

  Z  Air Intake Chamber
  ZZ  FV Sensor (

Shown without Bracket

)

 

INSTALL THERMAL EXPANSION

TANK IF WATER HEATER IS

INSTALLED IN A CLOSED 

WATER SYSTEM

VACUUM RELIEF

VALVE

*INSTALL PER

LOCAL CODES

IMPORTANT:

WHEN BRUSHING ON AN 
APPROVED NONCORROSIVE
LEAK DETECTION SOLUTION,
DO NOT SPLASH SOLUTION 
ONTO ELECTRICAL CON-
NECTIONS (SEE PAGE 27).

M

N

A

L

B

P

D

E

Q

F

G

DISCHARGE PIPE

(DO NOT CAP OR PLUG.)

H

I

W

K

FLOOR DRAIN

6” MAXIMUM 

AIR GAP

T

V

S

U

J

R

X

O

Z

Y

(S) GAS CONTROL VALVE/THERMOSTAT

 

IGNITER/
FLAME
SENSE
CONNECTOR

MANIFOLD TUBE

POWER SUPPLY
TRANSFORMER
CONNECTOR

PRESSURE
SWITCH/FAN,
FV SENSOR
CONNECTOR

DISPLAY, ANODE
ROD CONNECTOR

(U) NATURAL GAS BURNER ASSEMBLY

 

MANIFOLD DOOR GASKET

MANIFOLD COMPONENT 
BLOCK W/ RETAINER CLIP

BURNER

FLAME SENSE

HOT SURFACE

IGNITER

MANIFOLD

TUBE

MANIFOLD DOOR ASSEMBLY

IGNITER / FLAME SENSE
CONNECTOR  WIRE

IGNITER / FLAME SENSE
CONNECTOR WIRE

MANIFOLD DOOR ASSEMBLY

MANIFOLD TUBE

VIEW PORT

BURNER

ZZ

YY

*   INSTALL  IN  ACCORDANCE 

WITH LOCAL CODES.

*  DRIP LEG AS REQUIRED 

BY LOCAL CODES.

*  ALL PIPING MATERIALS

TO BE SUPPLIED BY 
CUSTOMERS.

TO VENT TERMINATION

ON ROOF

IMPORTANT: DO NOT USE AN EXTENSION CORD TO CONNECT 
THE WATER HEATER TO AN ELECTRICAL OUTLET.

FIGURE 1.

Содержание HIGH EFFICIENCY ATMOSPHERIC VENTGAS WATER...

Страница 1: ...pplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If t...

Страница 2: ...lief Valve 16 17 T P Relief Valve and Pipe Installation 17 Combination Space Heating Potable Water System 17 18 Solar Installation 18 Electrical Connections and Wiring Diagram 18 Important Information...

Страница 3: ...ty equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to...

Страница 4: ...s are available Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual Fire or Explosion Hazard Do not store or use gasoline or other flammable vapors...

Страница 5: ...CODES IMPORTANT WHEN BRUSHING ON AN APPROVED NONCORROSIVE LEAK DETECTION SOLUTION DO NOT SPLASH SOLUTION ONTO ELECTRICAL CON NECTIONS SEE PAGE 27 M N A L B P D E Q F G DISCHARGE PIPE DO NOT CAP OR PLU...

Страница 6: ...future users of this water heater will need it for future reference Service to the FVIR System should only be performed by a qualified technician Examples of a qualified technician include licensed pl...

Страница 7: ...ignition sources have been extinguished Fire or Explosion Hazard WARNING Read instruction manual before installing using or servicing water heater Improper use may result in fire or explosion Maintain...

Страница 8: ...ply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the metal drain pan that trigger an alarm or turn off the incoming water to the water heater when water...

Страница 9: ...PPLY WARNING Use a new CSA approved gas supply line Install a shut off valve Do not connect a natural gas water heater to an L P gas supply Do not connect an L P gas water heater to a natural gas supp...

Страница 10: ...these instructions can result in death explosion or carbon monoxide poisoning Explosion Hazard Gas Pipe Capacity Table WARNING Explosion Hazard Gas leaks can not always be detected by smell Gas suppl...

Страница 11: ...y a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do c...

Страница 12: ...for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may requi...

Страница 13: ...ing the manufacturer s instructions and local codes rules or regulations IMPORTANT If you lack the necessary skills required to properly install this venting system you should not proceed but get help...

Страница 14: ...prior to any elbow in the vent system IMPORTANT Existing vent systems must be inspected for obstructions corrosion and proper installation Chimney Connection IMPORTANT Before connecting a vent to a c...

Страница 15: ...he water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperature and pressure relief valve must be installed in the opening marked T...

Страница 16: ...or other chemicals must not be used Chemicals that may contaminate the potable water supply must not be added to the piping system Closed System Thermal Expansion As water is heated it expands thermal...

Страница 17: ...ed into the T P valve discharge opening per the instructions manual 4 Locate the hot water outlet cold water inlet pipes to the water heater 5 Locate the slit running the length of a section of pipe i...

Страница 18: ...tions for leaks Open the nearest hot water faucet and let it run for three 3 minutes to purge the water lines of air and sediment and to ensure complete filling of the tank The Electrical power may th...

Страница 19: ...se review the following checklist and make any required installation upgrades or changes Questions Contact Residential Technical Assistance by referencing the phone number on the front of the Installa...

Страница 20: ...performed 3 Set the ON OFF switch on the gas control to the OFF postition 2 6 This appliance is equipped with a device which automatically lights the burner DO NOT TRY TO LIGHT THE BURNER BY HAND This...

Страница 21: ...code 8 page 31 FIGURE 17 SEQUENCE OF OPERATION System will verify pressure switch operation and start a 5 second pre purge then air intake fan will turn off Ignitor will start a 12 second warm up peri...

Страница 22: ...hermostat see Figures 20 and 21 Using the lowest hot water temperature that meets your needs will also provide the most energy efficient operation of the water heater Never allow small children to use...

Страница 23: ...the water heater cannot be used until the gas control valve thermostat is replaced by a qualified technician Contact your local dealer for service information losses and may satisfy your normal hot wa...

Страница 24: ...s To drain the tank perform the following steps 1 Turn off the gas to the water heater at the manual gas shut off valve and turn off the electrical power to the gas control thermostat valve 2 Open a n...

Страница 25: ...Manifold Burner Assembly 1 Turn off the gas supply to the water heater at the manual gas shut off valve This valve is typically located beside the water heater Note the position of the shut off valve...

Страница 26: ...dirt it may be necessary to check the air intake chamber screen more frequently 2 Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen FIGU...

Страница 27: ...eater Refer to the section of Draining and Flushing section and follow the procedure 5 Disconnect the the flame sense hot surface igniter wire power supply transformer pressure switch fan and display...

Страница 28: ...PERATURE REGULATION section BURNER FLAME YELLOW LAZY 1 Dirt in burner ports 2 Combustion air path restricted 3 Not enough dilution air for proper com bustion 4 Main burner line clogged 5 Obstruction i...

Страница 29: ...MATION SOOTING 1 Insufficient secondary air 2 Low gas pressure 3 Water heater flue or vent system blocked 4 Thermostat not functioning properly 5 Heater installed in a confined area 6 Burner flame yel...

Страница 30: ...ure supply and manifold gas pressures are within requirements in the installation manual Manifold gas pressure is non adjustable if pressure is off by more than 0 3 W C 75 Pa replace the lower control...

Страница 31: ...power for 10 seconds and then back on If this error code will not clear and the ignitor resistance is within specifications replace the lower control 9 FV SENSE Flashing Flammable Vapor Sensor has det...

Страница 32: ...control must be replaced 15 All Segments Flashing The self diagnostic check has detected one or both of the temperature adjustment buttons are stuck 1 Press and release each of the temperature adjustm...

Страница 33: ...DURING TRIAL FOR IGNITION IGNITOR TURNS OFF YES NO IS FLAME SENSE LOST IS REQUEST FOR HEAT SATISFIED GAS VALVE OFF COMBUSTION FAN OFF AFTER POST PURGE DELAY GAS VALVE CLOSES LESS THAN 3 TRIES FOR IGN...

Страница 34: ...w Retainer Clip 16 Manifold Door Gasket 17 Viewport Assembly 18 FV Sensor 19 Outer Door 20 Electrical Transformer 21 Pressure Switch REPAIR PARTS ILLUSTRATION LEGEND Special anode rod see Anode Rod Wa...

Страница 35: ...assembly which contains the manifold tube gasket manifold door manifold component block with retainer clip and flame sense hot surface igniter assembly Natural Gas Item 15 Contains manifold component...

Страница 36: ...36 NOTES...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...niques for residential water heaters bearing a rating plate which has not been altered defaced or removed except as required by the warrantor used in an open system or in a closed system with a proper...

Страница 40: ...M DOES NOT CONSTITUTE PROOF OF PURCHASE OR PROOF OF INSTALLATION DISCLAIMERS NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE ON BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF THE HEATER...

Отзывы: