A.O. Smith High Efficiency 100 series Скачать руководство пользователя страница 39

39

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL 

OWNER ONLY in accordance with the warranty terms and 

conditions speci

fi

 ed below.

The warrantor will furnish the ORIGINAL OWNER,  1) a 

replacement water heater of equivalent size and current 

model if the glass-lined tank in this water heater leaks 

and,  2) a replacement part for any component part 

which fails. 
T H E   WAT E R   H E AT E R   R E P L A C E M E N T  M O D E L 

OR PART WILL BE WARRANTED FOR ONLY THE 

UNEXPIRED PORTION OF THE ORIGINAL WARRANTY.  

The warranty period will be determined by the original 

date of purchase of the water heater, or in the absence 

of a Bill of Sale verifying said date, from the date of 

manufacture indicated on rating plate affixed to this 

water heater.  This warranty is not transferable and 

applies to models listed below:

SERIES

TANK

PARTS

GCF, GCFL, GCFX 

6-Year

6-Year

When the water heater has been used for other than single 

family residential application;  

1.  The  tank warranty shall be reduced to 1 year for 6 year

 

models and to 3 years for 10 year models.  

2.  The parts warranty shall be reduced to 1 year for all 

 models. 

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is 

installed and operated in accordance with 1) all local 

fi

 re 

codes and plumbing codes, ordinances and regulations, 

2) the printed instructions provided with it, 3) good industry 

practices, and 4) proper safety practices such as but not 

limited to a properly sized drain pan if installed in an area 

where leakage from the tank or its connections would result 

in damage to the area adjacent to the heater.  In addition, a 

new temperature and pressure relief valve, certi

fi

 ed by the 

Canadian Gas Association must have been properly installed 

and piped to the nearest drain.
This warranty shall apply only when the heater is:
•  owned by the original purchaser;
•  installed for indoor operation only;
•  used at temperatures not exceeding the maximum 

 

calibrated setting of its thermostat;

•  used at water pressure not exceeding the working 

 

pressure shown on the heater;

• 

fi

 lled with potable water, free to circulate at all times and 

 

with the tank free of damaging water sediment or scale 

 deposits;
•  used in a non-corrosive and non-contaminated 

 atmosphere;
•  used with factory approved anode(s) installed;
•  in its original installation location;

•  in the United States, its territories or possessions, and 

 Canada;
•  sized in accordance with proper sizing techniques for 

 

residential water heaters;

•  bearing a rating plate which has not been altered, defaced 

 

or removed except as required by the warrantor;

•  used in an open system or in a closed system with a 

 

properly sized and installed thermal expansion tank;

•  operated with properly installed drip leg in the gas supply 

 line;
• 

fi

 red with the fuel for which it was factory built;

• 

fi

 red at the factory rated input;

•  operated with the inner and outer combustion chamber 

  doors in place and all factory seals to combustion 
 chamber 

intact.

•  installed with no attempted, nor actual modi

fi

 cation  or

  alteration of the water heater’s design in any way,

   including but not limited to, the attachment of non-
 

company approved appliances or equipment.

Any accident to the water heater or any part thereof (including 

freezing, 

fi

 re, 

fl

 oods, or lightning), any misuse, abuse or 

alteration of it, any operation of it in a modi

fi

 ed form, any 

operation of the water heater on desalinated (deionized) 

water, or any damage caused by attempts to repair tank 

leaks or parts, will void this warranty.  This warranty does 

not cover water heaters replaced for cosmetic reasons or for 

reasons of noise, taste, odor, discolored and/or rusty water.  

This warranty does not apply to water heaters used to heat 

pools, whirlpools or hot tubs or used for space heating where 

its sizing does not conform with speci

fi

 cations of the heating 

component manufacturer.
This warranty gives you speci

fi

 c legal rights, and you may 

have other rights which vary under the laws of each state. If 

any provision of this warranty is prohibited or invalid under 

applicable state law, that provision shall be ineffective to the 
extent of the prohibition or invalidity without invalidating the 
remainder of the affected provision or the other provisions of 
this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR 
WILL PROVIDE ONLY A REPLACEMENT WATER HEATER 
OR PART THEREOF. THE OWNER IS RESPONSIBLE FOR 
ALL OTHER COSTS. Such costs may include but are not 
limited to:
a.  Labor charges for service, removal, or reinstallation of 
 

the water heater or part thereof.

b.  Shipping and delivery charges for forwarding the new water 
 

heater or replacement part from the nearest distributor 

 

and returning the claimed defective heater or part to such 

 distributor. 
c.  All cost necessary or incidental for handling and 
  administrative charges, and for any materials and/or 
 

permits required for installation of the replacement heater 

 or 

part.

LIMITED RESIDENTIAL GAS WARRANTY

Содержание High Efficiency 100 series

Страница 1: ...ctrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fi...

Страница 2: ...Installation 17 Important Information About this Water Heater 18 Operating Your Water Heater 19 21 Lighting Instructions 19 Checking the Draft 20 Burner Flames 20 Emergency Shutdown 20 Water Temperat...

Страница 3: ...t water heaters and have a thorough understanding of this instruction manual Service Agency A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing air sup...

Страница 4: ...oid all ignition sources if you smell Natural or LP gas Do not expose water heater control to excessive gas pressure Use only gas shown on rating plate Maintain required clearances to combustibles Kee...

Страница 5: ...n Valve U Pilot and Main Burner V Flue W Metal Drain Pan X Igniter Wire Y Base Ring Filter Z FV Sensor AA Transformer BB Flue Damper ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS TO VENT TERMINATIO...

Страница 6: ...instructions you should not proceed but have a qualified technician perform the installation of this water heater Massachusetts code requires this water heater to be installed in accordance with Mass...

Страница 7: ...to clean the spill until all ignition sources have been extinguished Fire or Explosion Hazard WARNING Read instruction manual before installing using or servicing water heater Improper use may result...

Страница 8: ...ctor or water shut off device used in conjunction with a piped metal drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in variou...

Страница 9: ...ural gas water heater to an L P gas supply Do not connect an L P gas water heater to a natural gas supply Failure to follow these instructions can result in death explosion or carbon monoxide poisonin...

Страница 10: ...in the occurrence of a leak in the system the gas will settle at floor level Basements crawl spaces closets and areas below ground level will serve as pockets for the accumulation of gas Before lighti...

Страница 11: ...y a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do c...

Страница 12: ...typical examples of each method Louvers and Grilles In calculating free area for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louver...

Страница 13: ...re certified by CSA International this certification applies to the vent damper device only and does not mean they are certified for use on this water heater U L recognized fuel gas and carbon monoxid...

Страница 14: ...Before connecting a vent to a chimney make sure the chimney passageway is clear and free of obstructions The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces...

Страница 15: ...off valve in the cold water inlet line It should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperatu...

Страница 16: ...se excessive restriction to water flow is not recommended Use only 95 5 tin antimony or other equivalent solder Any lead based solder must not be used Piping that has been treated with chromates boile...

Страница 17: ...h duct tape 7 Repeat steps 5 and 6 for the hot water outlet pipe 8 Add additional sections of pipe insulation as needed T P RELIEF VALVE T P RELIEF VALVE MANUAL RELIEF LEVER T P RELIEF VALVE INSULATIO...

Страница 18: ...es Questions Contact Residential Technical Assistance by referencing the phone number on the front of the Installation Instructions and Use Care Guide Installation Checklist Water Heater Location Wate...

Страница 19: ...ier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to turn the gas control knob Never use tools If the...

Страница 20: ...emperature range of 120 F 140 F 49 C 60 C is recommended by most dishwasher manufacturers The thermostat of this water heater has been factory set at the VAC Vacation position It is adjustable and mus...

Страница 21: ...erature set by the user Vacation Setting The Vacation Setting VAC sets the controller at approximately 70 F This setting is recommended when the water heater is not in use for a long period of time Th...

Страница 22: ...YL YL BN 24VAC V 24VAC BK 120VAC WH 120VAC GR BK 24VAC HOT WH 24VAC NEUTRAL BL RD BL RD YL YL BK 24VAC HOT WH 24VAC NEUTRAL YL 24VAC YL 24VAC TRANSFORMER YL 24 VAC GAS CONTROL VALVE THERMOSTAT FV SENS...

Страница 23: ...ce information at 1 800 527 1953 A temperature limit switch or ECO Energy Cut Off sensor located in the gas control valve thermostat is used to shut off the water heater if the water temperature excee...

Страница 24: ...ting Your Water Heater See the Repair Parts Illustration section for anode rod location TEFLON is a registered trademark of E I Du Pont De Nemours and Company Draining and Flushing It is recommended t...

Страница 25: ...ush down slightly to free the manifold and pilot tube 7 Carefully remove the manifold assembly from the burner compartment NOTE Be sure not to damage internal parts Replacement Parts IMPORTANT The fol...

Страница 26: ...lot before going to the next step FIRST BEND S OTHER FITTINGS NOT SHOWN FOR CLARITY PILOT TUBE SCREWS OLD PILOT IGNITER FLAME SENSOR ASSEMBLY FIGURE 30 7 Push the new pilot tube and igniter wire throu...

Страница 27: ...ssembly door is tightened visually inspect the door gasket between the manifold burner assembly door and the combustion chamber for spaces or gaps that would prevent a seal IMPORTANT Do not operate th...

Страница 28: ...26 NOTE L P Gas systems use reverse left hand threads on the manifold tube 6 Refer to Gas Piping section Figure 5 and disconnect the ground joint union in the gas piping Disconnect the remaining pipe...

Страница 29: ...roubleshooting Table section 2 See Pilot Light Troubleshooting Flowchart section 3 Seat connector firmly in socket 4 Bleed the air from the gas line 5 Check with gas utility company 6 Check with gas u...

Страница 30: ...at COMBUSTION ODORS 1 Insufficient secondary air 2 Flue clogged 3 Heater installed in a confined area 1 Provide ventilation to water heater Check flue way flue baffle and burner 2 Clean locate source...

Страница 31: ...wer switch on the gas control valve to the OFF position and unplug the power cord from the power outlet 1 Attempt to depress the TCO door switch button see figure 27 If the TCO door switch button depr...

Страница 32: ...e electrode flame sense rod replace the igniter pilot assembly Follow the directions on page 27 to re install the burner assembly into the combustion chamber Follow the instructions for lighting on pa...

Страница 33: ...alve Open Is Main Flame Sensed Is Demand for Heat Satisfied Pilot Main Valve De Energize Is Flame Sensed Damper Energizes and Closes Will not light 8 4 flash error code See Corrective Action Table on...

Страница 34: ...List Item No Parts Description 1 DRAFT HOOD 2 FLUE DAMPER 3 FLUE BAFFLE 4 HEAT TRAP COLD SOME MODELS 5 HEAT TRAP HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE PRESSURE RELIEF VALVE L...

Страница 35: ...assembly which contains the manifold tube gasket door pilot igniter flame sensor assembly manifold component block with retainer clip thermal switch and pilot tube Natural Gas Low Nox Item 14B Manifol...

Страница 36: ...36 NOTES...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...in accordance with proper sizing techniques for residential water heaters bearing a rating plate which has not been altered defaced or removed except as required by the warrantor used in an open syst...

Страница 40: ...OF PURCHASE OR PROOF OF INSTALLATION DISCLAIMERS NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE ON BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF THE HEATER OR THE INSTALLATION OPERATI...

Отзывы: