A.O. Smith GPCR Скачать руководство пользователя страница 19

19

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER
ONLY.  If the glass lined tank in this water heater shall prove upon
examination by A. O. Smith Corporation (the warrantor) to have
leaked during the warranty period in normal residential use, due
to natural corrosion from potable water therein, the warrantor will
furnish the ORIGINAL OWNER a replacement A. O. Smith water
heater of equivalent size and current model, or a replacement part
for any component part which fails in normal use, in accordance
with the warranty terms and conditions specified below.  THE A. O.
SMITH REPLACEMENT MODEL OR PART WILL BE WARRANTED
FOR ONLY THE UNEXPIRED PORTION OF THE ORIGINAL
WARRANTY.  The warranty period will be determined by the original
installation date of the water heater. PROOF-OF-PURCHASE AND
PROOF-OF-INSTALLATION ARE NECESSARY TO VALIDATE THIS
WARRANTY.  This warranty is not transferable and applies to
models listed in Table 1.

TABLE 1

WARRANTY PERIOD

MODEL

TANK

1

PARTS

2

GPSH

6 YEARS

6 YEARS

GPCR

6 YEARS

6 YEARS

When the water heater has been used for other than single
family residential application: 1.  The  tank warranty shall be
reduced  to 1 year.  2. The parts warranty shall be reduced to 1
year for all models.  Returned parts which meet any of the
following conditions are not covered by this warranty: 1) improper
installation or removal; 2) damaged by other than normal wear;
3) replaced for cosmetic purposes; or 4) returned with defaced
date codes.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed
and operated in accordance with: 1) all local fire codes and
plumbing codes, ordinances and regulations; 2) the printed
instructions provided with it; 3) good industry practices; and 4)
proper safety practices such as but not limited to a properly
sized drain pan if installed in an area where leakage from
connections of the tank would result in damage to the area
adjacent to the heater.  In addition, a new temperature and
pressure relief valve, certified by the American Gas Association
must have been properly installed and piped to the nearest drain.

This warranty shall apply only when the heater is:

owned by the original purchaser;

used at temperatures not exceeding the maximum calibrated
setting of its thermostat;

not subjected to excessive water pressure fluctuations and
not subject to an operating pressure greater than 150 P.S.I.;

filled with potable water, free to circulate at all times and with
the tank free of damaging water sediment or scale deposits;

used in a non-corrosive and non-contaminated atmosphere;

used with factory approved anode(s) installed;

in its original installation location;

in the United States, its territories or possessions.

sized in accordance with proper sizing techniques for
residential water heaters;

bearing a rating plate which has not been altered, defaced or
removed except as required by the warrantor;

used in an open system or in a closed system with a properly
sized and installed thermal expansion tank;

fired at the factory rated input using the fuel stated in the face
of  the rating plate;

operated with the inner and outer combustion chamber doors
in place;

maintained in accordance with the instructions printed in the
manual included with the heater.

Any accident to the water heater or any part thereof (including
freezing, fire, floods, or lightning), any misuse, abuse or alteration
of it, any operation of it in a modified form, or any attempt to
repair tank leaks or parts, will void this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL
PROVIDE ONLY A REPLACEMENT WATER HEATER OR PART
THEREOF.  THE OWNER IS RESPONSIBLE FOR ALL OTHER
COSTS.  Such costs may include but are not limited to:

LIMITED RESIDENTIAL GAS WARRANTY

a.  Labor charges for service, removal, or reinstallation of the

water heater or part thereof.

b.  Shipping and delivery charges for forwarding the new water

heater or replacement part from the nearest distributor and
returning the claimed defective heater or part to such
distributor except in the state of California where such charges
are the manufacturer’s responsibility.

c.  All cost necessary or incidental for handling and administrative

charges, and for any materials and/or permits required for
installation of the replacement heater or part.

LIMITATION ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability
imposed on the sale of this heater under state law are limited to
one year duration for the heater or any of its parts.  Some states
do not allow limitations on how long an implied warranty lasts,
so the above limitations may not apply to you.

CLAIM PROCEDURE

Any claim under this warranty should be initiated with the dealer
who sold the heater, or with any other dealer handling the
warrantor’s products.  If this is not practical, the owner should
contact: A. O. Smith Water Products Company,  5621 West 115th
Street, Alsip, Illinois, 60803 (800) 323-2636.

The warrantor will only honor replacement with identical or
similar water heater or parts thereof which are manufactured or
distributed by the warrantor.

Dealer replacements are made subject to in-warranty validation
by warrantor.

PROOF-OF-PURCHASE AND PROOF-OF-INSTALLATION
DATES ARE REQUIRED TO SUPPORT WARRANTY FOR CLAIM
FROM ORIGINAL OWNER.  THIS FORM DOES NOT
CONSTITUTE PROOF-OF-PURCHASE OR PROOF-OF-
INSTALLATION.

DISCLAIMERS

NO EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN
BEHALF OF THE WARRANTOR WITH RESPECT TO THE
MERCHANTABILITY OF THE HEATER OR THE INSTALLATION,
OPERATION, REPAIR OR REPLACEMENT OF THE HEATER OR
PARTS.  THE WARRANTOR SHALL NOT BE RESPONSIBLE
FOR WATER DAMAGE, LOSS OF USE OF THE UNIT,
INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL
PROPERTY, OR OTHER CONSEQUENTIAL DAMAGE.  THE
WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS
WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS
OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND
WHETHER ARISING IN CONTRACT OR IN TORT.

Some states do not allow the limitation or exclusion of incidental
or consequential damages, so the above limitation or exclusion
may not apply to you.

This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

Fill out and keep with water heater.

IMPORTANT INFORMATION

  Model Number____________________________________________

  Serial Number_____________________________________________

  Installation Information:

  Date Installed _____________________________________________

  Company’s Name _________________________________________

  Street or P.O. Box _________________________________________

  City, State, and Zip Code  ___________________________________

  Phone Number _______________Plumber’s Name_______________

Содержание GPCR

Страница 1: ...tion and or operation of this water heater Please pay particular attention to the important safety and operating instructions as well as the WARNINGS and CAUTIONS CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE OWNER S MANUAL GET TO KNOWYOUR WATER HEATER 2 GENERAL SAFETYINFORMATION 3 INSTALLATION...

Страница 2: ...bers see rating plate quantity and name of part desired as listed in Figure 1 Standard hardware items may be purchased locally GAS MODELS WITH HOT SURFACE IGNITION 2 OR 3 PVC VENT CAPABILITY FIGURE 1 O Flue Baffle Assembly P Insulation Q Control Harness R Rating Plate S Gas Supply T Manual Gas Shut off Valve U Ground Joint Union V Dirt Leg Sediment Trap W Drain Valve X Gas Valve Thermostat Y Drain...

Страница 3: ...eep it on the side of the water heater or nearby for future reference Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels Do inspect the insulation blanket frequently to make certain it does not sag thereby obstructing combustion air flow GENERAL SAFETY INFORMATION EXTERNAL DAMAGE Do not operate the water heater until it has been fully checke...

Страница 4: ...having jurisdiction In the absence of local codes the installation must comply with the current editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the National Electrical Code NFPA 70 The former is available from the Canadian Standards Association 8501 East Pleasant Valley Road Cleveland OH 44131 and both documents are available from the National Fire Protection Association 1 Batteryma...

Страница 5: ...l be suitable for use with potable water 2 Toxic chemicals such as those used for boiler treatment shall NEVER be introduced into this system 3 This unit may NEVER be connected to any existing heating system or component s previously used with a non potable water heating appliance 4 When the system requires water for space heating at temperatures higher than required for domestic water purposes a ...

Страница 6: ...SI Z223 1 NFPA54 7 3 4e and 7 8a b as follows 1 The exit terminals of a mechanical vent system shall be not less than 7 feet above grade when located adjacent to public walkways Figure 3 2 A venting system shall terminate at least 3 feet above any forced air inlet located within 10 feet Figure 3 3 The venting system shall terminate at least 4 feet below 4 feet horizontally from or 1 foot above any...

Страница 7: ... wall and install the wall plate can be held to the outside wall by placing some of the caulking on the back of the plate The wall plate is supplied for decorative purposes only and is not a requirement for the vent termination if not needed by the installer SEQUENCEOFINSTALLATION 1 The Power Vent Models come with the blower assembly installed 2 After the unit is set in place make sure the blower ...

Страница 8: ...power cord until vent system is completely installed The Power Vent operates on 110 120 Vac therefore a grounded outlet must be within reach of the six 6 foot flexible power cord supplied with the unit see fig 1 The power cord supplied may be used only where local codes permit If local codes do not permit the use of a flexible power supply cord a Make sure the unit is unplugged from wall outlet Re...

Страница 9: ...pages 10 through 12 for the proper method of cutting and cementing the PVC pipe and fittings 4 The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps The adapter and clamps are provided with the heater 5 Even though the flue gas temperature leaving the blower is between 140 F and 175 F some installations will have water condense in the vent piping If t...

Страница 10: ...far the majority of failures in PVC and CPVC systems are the result of shortcuts and or improper joining techniques 2 SELECTIONOFMATERIALS Cutting Device Saw or Pipe Cutter Deburring Tool Knife File or Beveling Machine 2 and above Brush Pure Bristle Rag Cotton Not Synthetic Primer and Cleaner Solvent Cement PVC for PVC Components and CPVC for CPVC Components Containers Metal or Glass to hold Prime...

Страница 11: ... fitting sockets and remove all dirt grease or moisture with a clean dry rag If wiping fails to clean the surfaces a chemical cleaner must be used Check for possible damage such as splits or cracks and replace if necessary Depth of entry Marking the depth of entry is a way to check if the pipe has reached the bottom of the fitting socket in Step F Measure the fitting depth and mark this distance o...

Страница 12: ...hot water line Make sure that the insulation is against the top cover of the heater Fit T P valve insulation over valve Make sure that the insulation does not interfere with the lever of the T P valve Secure all insulation using tape OPERATION WARNING NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF ...

Страница 13: ...OLER and HOTTER buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Turn off all electric power to the appliance if service is to be performed BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATERANDAIR PURGED FROMALL LINES 1 STOP Read the safety information above on...

Страница 14: ... you experience this type of use you should consider using lower temperature settings to reduce scald hazards Valves for reducing the point of use temperature by mixing cold and hot water are available See figure 2 Also available are inexpensive devices that attach to faucets to limit hot water temperatures Contact a licensed plumber or the local plumbing authority To avoid any unintentional chang...

Страница 15: ...TY INFORMATION SECTION FIRST USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME THE GAS CARRYING COMPONENTS OFTHISAPPLIANCE SHOULD BE INSPECTED FOR PROPER OPERATION PERIODICALLY BY A QUALIFIED SERVICE TECHNICIAN MAIN BURNER FIG 1 Check main burner every 12 months for proper flame characteristics This is done by removing door s on heater fig 1 The main burner...

Страница 16: ...e will damage the heater Turn off the gas and cold water inlet valve to the heater Open a nearby hot water faucet and the heater drain valve BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE HAND IS NOT EXPOSED TO HOT WATER IF DESIRED A HOSE MAY BE CONNECTED TO THE DRAIN VALVETO CARRYTHE WATERAWAY DANGER THE WATER MAYBE HOT The drain valve must be left open during the shutdown period To resta...

Страница 17: ... correct and secure 2 Replace hot surface ignitor System in lockout 1 Gas supply is off or too low to operate 2 Hot surface ignitor not positioned correctly 3 Low voltage to the water heater 4 Electric polarity to unit is incorrect test and correct Problem in the gas valve driver circuit 1 Turn power to the water heater off for 10 seconds and the back on 2 Replace gas control valve Problem with th...

Страница 18: ...ng and YELLOWFLAME air openings in bottom base pan for obstructions or blockage C Not enough dilution air for proper Check dilution air intake for obstructions combustion or blockage A Water on the floor under heater See CONDENSATION section B Water dripping from blower assembly Install condensate drain hose supplied locally CONDENSATION on drain port of rubber boot of blower assembly or provide a...

Страница 19: ...y accident to the water heater or any part thereof including freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified form or any attempt to repair tank leaks or parts will void this warranty SERVICE AND LABOR RESPONSIBILITY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLYA REPLACEMENT WATER HEATER OR PART THEREOF THE OWNER IS RESPONSIBLE ...

Страница 20: ...20 5621 W 115TH STREET ALSIP IL 60803 PHONE 1 800 433 2545 FAX 1 800 433 2515 www hotwater com E mail parts hotwater com REPLACEMENT PARTS ...

Отзывы: