background image

14

TEMPERATURE REGULATION

 WARNING

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE
THERMOSTAT TO CONTROL WATER TEMPERATURE.  HOT
WATER TEMPERATURES REQUIRED FOR AUTOMATIC
DISHWASHER  AND LAUNDRY USE CAN CAUSE PAINFUL
SCALDING WITH POSSIBLE SERIOUS AND PERMANENT
INJURY.  THE TEMPERATURE AT WHICH INJURY OCCURS
VARIES WITH  THE PERSON'S AGE AND THE TIME OF
EXPOSURE.  THE SLOWER RESPONSE TIME OF CHILDREN,
AGED OR DISABLED PERSONS INCREASES THE HAZARDS
TO THEM.  NEVER ALLOW SMALL CHILDREN TO USE A HOT
WATER TAP OR TO DRAW THEIR OWN BATH WATER.  NEVER
LEAVE A CHILD OR DISABLED PERSON UNATTENDED IN A
BATHTUB OR SHOWER.

THE WATER HEATER SHOULD BE LOCATED IN AN AREA
WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS.

It is recommended that lower water temperatures be used to
avoid the risk of scalding.  It is further recommended, in all cases,
that the water temperature be set for the lowest temperature
which satisfies your hot water needs.  This will also provide the
most energy efficient operation of the water heater.  The water
temperature setting was factory set at the lowest temperature;
Pressing the “COOLER”   button decreases temperature and
pressing the “HOTTER” 

 button increases the temperature.

SETTING THE WATER HEATER TEMPERATURE AT 120°F
(APPROX. "

" MARK ON TEMPERATURE SETTING OF GAS

VALVE)  WILL REDUCE THE RISK OF SCALDS

.  Some states

require settings at specific lower temperatures.

Figure 9 shows the approximate water temperatures produced
at various thermostat settings.  Short repeated heating cycles
caused by small hot water uses can cause temperatures at the
point of use to exceed the thermostat setting by up to 30°F (17ºC).
If you experience this type of use you should consider using
lower temperature settings to reduce scald hazards.

Valves for reducing the point-of-use temperature by mixing cold
and hot water are available.  See figure 2. Also available are
inexpensive devices that attach to faucets to limit hot water
temperatures.  Contact a licensed plumber or the local plumbing
authority.

To avoid any unintentional changes in water temperature settings,
the control has a tamper resistant feature for changing the
temperature setting. To change the temperature setting follow
these instructions:

1. “Wake Up” the temperature indicators by holding down both

“COOLER” and “HOTTER” temperature adjustment buttons
at the same time for one second (See Figure 9). One or two of
the temperature indicators will light up. These indicators will
only remain on for 30 seconds if no further buttons are
pressed. After 30 seconds the control will go back to “Sleep”
mode.

2. Release both of the temperature adjustment buttons.

A. To decrease the temperature press and release the

“COOLER” button until the desired setting is reached.

B. To increase the temperature press and release the

“HOTTER” button until the desired setting is reached.

NOTE: Holding down the button will not continue to lower or
raise the temperature setting. The button must be pressed and
released for each temperature change desired.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL
TO SHUTOFF, TURN OFF THE MANUAL GAS CONTROL VALVE
TO THE APPLIANCE.  SEE FIGURE 1(G).

           

Time to Produce

Display

2nd & 3rd Degree

Temperature Setting

A B C

Burns on Adult Skin

C - Flashing = approx.  160°F

About  1/2 seconds

C = approx. 150°F

About 1-1/2 seconds

B = approx. 140°F

Less than 5 seconds

A = approx. 130°F

About 30 seconds

= approx.  120°F

More than 5 minutes

WARM = approx. 80°F

- - - - - - - - - - - - - - -

FIGURE 9

TEMPERATURE INDICATORS

TEMPERATURE ADJUSTMENT BUTTONS

Содержание GPCR

Страница 1: ...tion and or operation of this water heater Please pay particular attention to the important safety and operating instructions as well as the WARNINGS and CAUTIONS CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE OWNER S MANUAL GET TO KNOWYOUR WATER HEATER 2 GENERAL SAFETYINFORMATION 3 INSTALLATION...

Страница 2: ...bers see rating plate quantity and name of part desired as listed in Figure 1 Standard hardware items may be purchased locally GAS MODELS WITH HOT SURFACE IGNITION 2 OR 3 PVC VENT CAPABILITY FIGURE 1 O Flue Baffle Assembly P Insulation Q Control Harness R Rating Plate S Gas Supply T Manual Gas Shut off Valve U Ground Joint Union V Dirt Leg Sediment Trap W Drain Valve X Gas Valve Thermostat Y Drain...

Страница 3: ...eep it on the side of the water heater or nearby for future reference Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels Do inspect the insulation blanket frequently to make certain it does not sag thereby obstructing combustion air flow GENERAL SAFETY INFORMATION EXTERNAL DAMAGE Do not operate the water heater until it has been fully checke...

Страница 4: ...having jurisdiction In the absence of local codes the installation must comply with the current editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the National Electrical Code NFPA 70 The former is available from the Canadian Standards Association 8501 East Pleasant Valley Road Cleveland OH 44131 and both documents are available from the National Fire Protection Association 1 Batteryma...

Страница 5: ...l be suitable for use with potable water 2 Toxic chemicals such as those used for boiler treatment shall NEVER be introduced into this system 3 This unit may NEVER be connected to any existing heating system or component s previously used with a non potable water heating appliance 4 When the system requires water for space heating at temperatures higher than required for domestic water purposes a ...

Страница 6: ...SI Z223 1 NFPA54 7 3 4e and 7 8a b as follows 1 The exit terminals of a mechanical vent system shall be not less than 7 feet above grade when located adjacent to public walkways Figure 3 2 A venting system shall terminate at least 3 feet above any forced air inlet located within 10 feet Figure 3 3 The venting system shall terminate at least 4 feet below 4 feet horizontally from or 1 foot above any...

Страница 7: ... wall and install the wall plate can be held to the outside wall by placing some of the caulking on the back of the plate The wall plate is supplied for decorative purposes only and is not a requirement for the vent termination if not needed by the installer SEQUENCEOFINSTALLATION 1 The Power Vent Models come with the blower assembly installed 2 After the unit is set in place make sure the blower ...

Страница 8: ...power cord until vent system is completely installed The Power Vent operates on 110 120 Vac therefore a grounded outlet must be within reach of the six 6 foot flexible power cord supplied with the unit see fig 1 The power cord supplied may be used only where local codes permit If local codes do not permit the use of a flexible power supply cord a Make sure the unit is unplugged from wall outlet Re...

Страница 9: ...pages 10 through 12 for the proper method of cutting and cementing the PVC pipe and fittings 4 The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps The adapter and clamps are provided with the heater 5 Even though the flue gas temperature leaving the blower is between 140 F and 175 F some installations will have water condense in the vent piping If t...

Страница 10: ...far the majority of failures in PVC and CPVC systems are the result of shortcuts and or improper joining techniques 2 SELECTIONOFMATERIALS Cutting Device Saw or Pipe Cutter Deburring Tool Knife File or Beveling Machine 2 and above Brush Pure Bristle Rag Cotton Not Synthetic Primer and Cleaner Solvent Cement PVC for PVC Components and CPVC for CPVC Components Containers Metal or Glass to hold Prime...

Страница 11: ... fitting sockets and remove all dirt grease or moisture with a clean dry rag If wiping fails to clean the surfaces a chemical cleaner must be used Check for possible damage such as splits or cracks and replace if necessary Depth of entry Marking the depth of entry is a way to check if the pipe has reached the bottom of the fitting socket in Step F Measure the fitting depth and mark this distance o...

Страница 12: ...hot water line Make sure that the insulation is against the top cover of the heater Fit T P valve insulation over valve Make sure that the insulation does not interfere with the lever of the T P valve Secure all insulation using tape OPERATION WARNING NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF ...

Страница 13: ...OLER and HOTTER buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Turn off all electric power to the appliance if service is to be performed BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATERANDAIR PURGED FROMALL LINES 1 STOP Read the safety information above on...

Страница 14: ... you experience this type of use you should consider using lower temperature settings to reduce scald hazards Valves for reducing the point of use temperature by mixing cold and hot water are available See figure 2 Also available are inexpensive devices that attach to faucets to limit hot water temperatures Contact a licensed plumber or the local plumbing authority To avoid any unintentional chang...

Страница 15: ...TY INFORMATION SECTION FIRST USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME THE GAS CARRYING COMPONENTS OFTHISAPPLIANCE SHOULD BE INSPECTED FOR PROPER OPERATION PERIODICALLY BY A QUALIFIED SERVICE TECHNICIAN MAIN BURNER FIG 1 Check main burner every 12 months for proper flame characteristics This is done by removing door s on heater fig 1 The main burner...

Страница 16: ...e will damage the heater Turn off the gas and cold water inlet valve to the heater Open a nearby hot water faucet and the heater drain valve BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE HAND IS NOT EXPOSED TO HOT WATER IF DESIRED A HOSE MAY BE CONNECTED TO THE DRAIN VALVETO CARRYTHE WATERAWAY DANGER THE WATER MAYBE HOT The drain valve must be left open during the shutdown period To resta...

Страница 17: ... correct and secure 2 Replace hot surface ignitor System in lockout 1 Gas supply is off or too low to operate 2 Hot surface ignitor not positioned correctly 3 Low voltage to the water heater 4 Electric polarity to unit is incorrect test and correct Problem in the gas valve driver circuit 1 Turn power to the water heater off for 10 seconds and the back on 2 Replace gas control valve Problem with th...

Страница 18: ...ng and YELLOWFLAME air openings in bottom base pan for obstructions or blockage C Not enough dilution air for proper Check dilution air intake for obstructions combustion or blockage A Water on the floor under heater See CONDENSATION section B Water dripping from blower assembly Install condensate drain hose supplied locally CONDENSATION on drain port of rubber boot of blower assembly or provide a...

Страница 19: ...y accident to the water heater or any part thereof including freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified form or any attempt to repair tank leaks or parts will void this warranty SERVICE AND LABOR RESPONSIBILITY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLYA REPLACEMENT WATER HEATER OR PART THEREOF THE OWNER IS RESPONSIBLE ...

Страница 20: ...20 5621 W 115TH STREET ALSIP IL 60803 PHONE 1 800 433 2545 FAX 1 800 433 2515 www hotwater com E mail parts hotwater com REPLACEMENT PARTS ...