drained by the T&P relief valve, or otherwise the water heater or the tube system will be
damaged.
For this condition, refer to the local code or consult with the inspection agency to
determine which system can be accepted in the area. This includes:
a) Install the second T&P relief valve and set the pressure lower than the pressure setting of
the first T&P relief valve.
b) Install an expanded tank with appropriate pressure to relief the heat expansion.
4. Check the heating elements for leakage. If you cannot find the reason by yourself,
a) Please disconnect the power supply to the heater.
b) Close the water supply valve of the water heater.
c) Contact with the supplier.
7.5 Diagnostic Codes
Table 7.1
DISPLAY INDICATES
CORRECTIVE
ACTION
AMB
SHORT
Ambient temperature sensor is short.
Call the service phone.
AMB
OPEN
Ambient temperature sensor is open.
Call the service phone.
AMB
ADERR
Ambient temperature AD channel is error.
Call the service phone.
DIS
SHORT
Discharge temperature sensor is short.
Call the service phone.
DIS
OPEN
Discharge temperature sensor is open.
Call the service phone.
DIS
ADERR
Discharge temperature AD channel is error.
Call the service phone.
HIGH
PRESSURE
Compressor is protected for high pressure.
If it cannot recover within one hour, call the service phone.
LOW
PRESSURE
Compressor is protected for low pressure.
If it cannot recover within one hour, call the service phone.
HIGH
DISTEMP
Compressor is protected for high discharge
temperature.
If it cannot recover within one hour, call the service phone.
FAN
LOST
Fan motor is unconnected.
Call the service phone.
COMPRE
LOST
Compressor is unconnected.
Call the service phone.
SUC
SHORT
Suction temperature sensor is short.
Call the service phone.
SUC
OPEN
Suction temperature sensor is open.
Call the service phone.
SUC
ADERR
Suction temperature AD channel is error.
Call the service phone.
COND
OVERFLOW
Condensate water flow out of the drain pan.
Call the service phone.
LOW
VOLTAGE
Low voltage alarms.
It will recover automatically.
HIGH
VOLTAGE
High voltage alarms.
It will recover automatically.
COIL
BLOCKED
Heat exchanger is blocked.
Call the service phone.
LOW
WATER
Water lever in tank is low.
Disconnect the power and charge enough water, and then
connect the power supply.
ECO
ECO is error.
Call the service phone.
UPPER
SHORT
Upper tank temperature sensor is short.
Call the service phone.
UPPER
OPEN
Upper tank temperature sensor is open.
Call the service phone.
UPPER
ADERR
Upper tank temperature AD channel is error.
Call the service phone.
CRYSTAL
ERR
Crystal is error.
Call the service phone.
RAM
EER
RAM memory is error.
Call the service phone.
ROM
EER
ROM memory is error.
Call the service phone.
VERY
LOWVOLT
Extra low voltage alarming.
It will recover automatically.