LP gas must be used with great caution.  It is highly explosive 

and heavier than air.  It collects first in the low areas making its 

odor difficult to detect at nose level.  If LP gas is present or even 

suspected, do not attempt to find the cause yourself.  Go to a 

neighbor's house, leaving your doors open to ventilate the house, 

then call your gas supplier or service agent.  Keep area clear until 

a service call has been made.

At times you may not be able to smell an LP gas leak.  One cause 

is odor fade, which is a loss of the chemical odorant that gives 

LP gas its distinctive smell.  Another cause can be your physical 

condition, such as having a cold or a diminishing sense of smell 

with age.  For these reasons, the use of a propane gas detector 

is recommended.

IF  YOU  EXPERIENCE AN  OUT-OF-GAS  SITUATION,  DO 

NOT TRY TO  RELIGHT APPLIANCES YOURSELF.   Ask  your 

LP  delivery  person  to  relight  pilots  for  you.    Only  trained  LP 

professionals  should  conduct  the  required  safety  checks  in 

accordance with industry standards.  

EXTENDED NON-USE PERIODS

 

WARNING

HYDROGEN  GAS  CAN  BE  PRODUCED  IN A  HOT  WATER 

SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN 

USED  FOR A  LONG  PERIOD  OF TIME  (GENERALLY TWO 

WEEKS  OR  MORE).   

HYDROGEN  GAS  IS  EXTREMELY 

FLAMMABLE.

  To reduce the risk of injury under these conditions, 

it is recommended that the hot water faucet be opened for several 

minutes at the kitchen sink before using any electrical appliance 

connected to the hot water system.  If hydrogen is present, there 

will probably be an unusual sound such as air escaping through 

the pipe as the water begins to flow.  

THERE SHOULD BE NO 

SMOKING OR OPEN FLAME NEAR THE FAUCET AT THE TIME 

IT IS OPEN. 

INSULATION BLANKETS

Insulation  blankets  available  to  the  general  public  for  external 

use on gas water heaters are not necessary with this product.  

The purpose of an insulation blanket is to reduce the standby 

heat  loss  encountered  with  storage  tank  heaters. Your  water 

heater meets and exceeds the Energy Policy Act with respect to 

insulation and standby loss requirements, making an insulation 

blanket unnecessary.

 WARNING

Should  you  choose  to  apply  an  insulation  blanket  to  this 

heater, you should follow these instructions (See Figure 1 for 

identification of components mentioned below).  Failure to follow 

these instructions can restrict the air flow required for proper 

combustion, potentially resulting in fire, asphyxiation, serious 

personal injury or death.

• 

Do not

 cover the gas valve or temperature & pressure relief 

valve.

• 

Do not

 allow insulation to come within 2" (5.1 cm) of the dilution 

air inlet on the blower, to prevent blockage of the dilution air.

• 

Do not

 allow insulation to come within 2" (5.1 cm) of the floor 

to prevent blockage of combustion air flow to the burner.

GENERAL SAFETY INFORMATION

EXTERNAL DAMAGE

Do not operate the water heater until it has been fully checked out 

by a qualified technician, if the water heater:

  •  Has been exposed to fire or damage.
  •  Displays evidence of sooting.
  •  Produces steam or unusually hot water.

If  the  water  heater  has  been  subject  to  flooding  it  must  be 

replaced.

CHEMICAL VAPOR CORROSION

 WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY 

OCCUR    IF AIR  FOR  COMBUSTION  CONTAINS  CERTAIN 

CHEMICAL VAPORS.     SUCH CORROSION MAY RESULT IN 

FAILURE AND RISK OF ASPHYXIATION.

Spray  can  propellants,  cleaning  solvents,  refrigerator  and  air 

conditioning refrigerants, swimming pool chemicals, calcium and 

sodium chloride (water softener salt), waxes, and process chemicals 

are typical compounds which are potentially corrosive.

Do not store products of this sort near the heater.  Also, air 

which is brought in contact with the heater should not contain 

any  of  these  chemicals.    If  necessary,  uncontaminated  air 

should  be  obtained  from  remote  or  outside  sources.  The 

limited warranty is voided when failure of water heater is due 

to a corrosive atmosphere.  (See limited warranty for complete 

terms and conditions).

IMPROPER COMBUSTION

 WARNING

ATTIC  AND/OR  EXHAUST  FANS  OPERATING  ON  THE 

PREMISES WITH A WATER HEATER CAN RESULT IN CARBON 

MONOXIDE POISONING AND DEATH.

OPERATION OF THESE FANS CAN PRODUCE A NEGATIVE 

DRAFT IN THE AREA OF THE WATER HEATER PREVENTING 

THE  PRODUCTS  OF  COMBUSTION  FROM  EXHAUSTING 

THROUGH THE VENT PIPE.

The venting of the water heater should be inspected by a qualified 

service  technician  at  the  time  of  installation  and  periodically 

thereafter to ensure a down-draft condition does not exist.

DO  NOT  OBSTRUCT  THE  FLOW  OF  COMBUSTION AND 

VENTILATING AIR.  ADEQUATE AIR FOR COMBUSTION AND 

VENTILATION MUST BE PROVIDED FOR SAFE OPERATION.

LIQUID PETROLEUM MODELS

 

WARNING

Water heaters for propane or liquefied petroleum gas (LPG) are 

different from natural gas models.  A natural gas heater will not 

function  safely  on  LP  gas  and  no  attempt  should  be  made  to 

convert a heater from natural gas to LP gas.

Содержание BTF-80

Страница 1: ...ONS CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE MODEL BTF 80 COMMERCIAL POWER VENT GAS WATER...

Страница 2: ...These shall be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made The installation must conform to these instructions and the local code...

Страница 3: ...at 500 Tennessee Waltz Parkway Ashland City TN 37015 When ordering parts provide complete model and serial numbers see rating plate quantity and name of part desired as listed in Figure 1 Standard har...

Страница 4: ...the air flow required for proper combustion potentially resulting in fire asphyxiation serious personal injury or death Do not cover the gas valve or temperature pressure relief valve Do not allow in...

Страница 5: ...learance of 4 10 cm must be allowed for access to replaceable parts such as the thermostats drain valve and relief valve A top clearance of 24 61 cm should be allowed for blower assembly service Adequ...

Страница 6: ...st be checked for safe operation Make sure that the outside vents on the supply regulators and the safety vent valves are protected against blockage These are parts of the gas supply system not the he...

Страница 7: ...7 FIGURE 3 WARNING VENT HOOD S MAY BE EXTREMELY HOT DURING OPERATION U S HORIZONTAL VENT CLEARANCES CANADIAN HORIZONTAL VENT CLEARANCES...

Страница 8: ...ION CHECK FOR GAS LEAKAGE USE SOAP AND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE DO NOT USE MATCHES CANDLES FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS RELIEF VALVE A NEW...

Страница 9: ...1785 or Cellular Core Schedule 40 DWV ASTM F 891 Schedule 40 CPVC ASTM F 441 orABS ASTM D 2661 pipe The fittings other than the TERMINATION 45 ELBOW should be equivalent to PVC DWV fittings meetingAS...

Страница 10: ...against the wall after installation If the vent pipe is installed up to the wall with a coupling on the end against the wall opening the pipe with the vent terminal can be prepared for gluing before...

Страница 11: ...OWER VENT WIRING SCHEMATIC FIGURE 7 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVIC...

Страница 12: ...e where it exits the roof The total vent system should not exceed the thirty 30 equivalent feet 9 1 equivalent meters of 3 inch pipe or one hundred 100 equivalent feet 30 5 equivalent meters of 4 inch...

Страница 13: ...ing characteristics IMPORTANT NOTE A dauber type applicator should only be used on pipe sizes 2 5 1 cm and below For larger diameter pipe a brush or roller must be used 3 MAKING THE JOINT A Cutting Pi...

Страница 14: ...tting will have a tendency to slide back while the cement is still wet so hold the joint together for about 15 seconds STEP F G Cleanup and joint movement Remove all excess cement from around the pipe...

Страница 15: ...follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM AL...

Страница 16: ...RESPONSE TIME OF CHILDREN AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP OR TO DRAW THEIR OWN BATH WATER NEVER LEAVE A CHILD OR DISABLED PERS...

Страница 17: ...heater for several minutes and check to see if it is venting properly by passing a lit match or paper near the opening of the Air Mixing Box See figure 11 If the draft is proper the match flame will b...

Страница 18: ...oted above If you are having a problem with your water heater before calling for service please refer to the following TROUBLE SHOOTING sections If service becomes necessary contact your dealer instal...

Страница 19: ...r service to outlet Replace switch Replace control harness Replace blower and motor Replace switch Check for low voltage less than 102 vac have service checked and repaired Ifvoltageisabove102vac make...

Страница 20: ...circuit 1 Turn power to the water heater off for 10 seconds and then back on 2 Replace gas control valve Problem with the internal circuit 1 Turn power to the water heater off for 10 seconds and then...

Страница 21: ...21 NOTES...

Страница 22: ...22 NOTES...

Страница 23: ...23 NOTES...

Страница 24: ...eptable method 4 SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will provide only a replacement water heater or part thereof The owner is responsible for all other costs Such cos...

Отзывы: