background image

18

If the heater is to be shut off and exposed to freezing temperatures, 

it must be drained.  Water, if left in the tank and allowed to freeze, 

will damage the heater.

•  Turn off the gas and cold water inlet valve to the heater.

 

•  Open a nearby hot water faucet and the heater drain valve.

•  BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO 

THAT THE HAND IS NOT EXPOSED TO HOT WATER.  IF 

DESIRED, A HOSE MAY BE CONNECTED TO THE DRAIN 

VALVE TO CARRY THE WATER AWAY.

 

 

  WARNING:  The water CAN BE HOT.

The drain valve must be left open during the shutdown period.

•  To restart heater, refer to the instructions under OPERATION.

CONDENSATION

Water  vapor  can  condense  on  the  cooler  surfaces  of  the  tank 

forming droplets, these drip into the fire or run out on the floor.  

This is common at the time of startup after installation, during 

periods of time when incoming water is very cold, or if the water 

heater is undersized for the application.

Droplets  from  the  bottom  of  the  flue  may  be  due  to  corrosive 

combustion products or improper vent.  Check with your dealer 

for more information.

CATHODIC PROTECTION-ANODE

The anode rod is used to protect the tank from corrosion.  Most 

hot water tanks are equipped with an anode rod.  The submerged 

rod sacrifices itself to protect the tank.  Instead of corroding the 

tank, water ions attack and eat away the anode rod.  This does 

not affect the water’s taste or color.  The rod must be maintained 

to keep the tank in operating condition.

Anode  deterioration  depends  on  water  conductivity,  not 

necessarily water condition.  A corroded or pitted anode rod 

indicates high water conductivity and should be checked and/

or replaced more often than an anode rod that appears to be 

intact.  Replacement of a depleted anode rod can extend the 

life of your water heater.  Inspection should be conducted by 

a qualified technician, and at a minimum should be checked 

annually after the warranty period.

A hydrogen sulfide (rotten egg) odor may result if water contains 

high  sulfate  and/or  minerals.    Chlorinating  the  water  supply 

should  minimize  the  problem.    (See  EXTENDED  NON-USE 

PERIODS).

NOTE:

 Anode  must  remain  installed  (except  for  inspection)  to 

avoid shortening tank life.  See LIMITED WARRANTY.  Replace 

as necessary.

SERVICE AND REPAIR

The water heater requires no special care other than the normal 

maintenance as noted above.  If you are having a problem with 

your water heater, before calling for service please refer to the 

following TROUBLE SHOOTING sections.  If service becomes 

necessary,  contact  your  dealer,  installer  or  an  authorized 

service  agent.    Do  not  attempt  to  repair  the  water  heater 

yourself.  Any work performed by unauthorized personnel may 

void the warranty.

If you are having a problem with your water heater and are not 

pleased with the service you received:

•  First, please contact your dealer or the authorized service agent 

in your area and explain to them why you are not satisfied.  This 

will usually correct the problem.

•  If after working with your dealer or service agent the problem 

has  not  been  resolved  to  your  satisfaction,  please  let  us 

know by either going to our website and e-mailing us or by 

addressing  an  envelope  to  the  manufacturer  listed  on  the 

rating plate at:

  Service Department

  500 Tennessee Waltz Parkway

  Ashland City, TN 37015

Please be sure to provide the following information when writing 

or e-mailing:

  •  Model Number             

  •  Serial Number

  •  Date of Original Purchase

  •  Date Problem Originated

  •  Explanation of Problem

Also, please be sure to include a daytime telephone number.

TROUBLE SHOOTING

Water  heater  may  exhibit  problems  that  are  unrelated  to  a 

malfunction of the water heater itself.  The following information 

and tables may serve to answer your question about a problem 

that you are having without having to call a service agent.

For your safety, water heater service should be performed only 

by a qualified service technician.  Read the GENERAL SAFETY 

INFORMATION section first.

WATER HEATING IGNITION SEQUENCE

(Make sure gas and electric power are connected properly)

1)  The  ignition  control  module  is  powered  and  monitors  the 

system, waiting for a call for heat from the thermostat.

2)  The thermostat calls for heat by reading a resistance value within 

a given range directly proportional to water temperature.

3)  The Control Module:

  a)  Check the pressure switches for an open circuit.

  b)  Energizes the blower.

  c)  Checks the pressure switches for a closed circuit to prove draft.

  d)  Sends  line  voltage  to  the  hot  surface  igniter  with  a 

20-second warm up period.

  e)  Opens  the  gas  valve  and  check  the  sensing  rod  for 

flame.

4)  The burner heats the water to the desired thermostat setting.

  a)  The resistance in the thermostat rises to the value selected 

by the temperature control knob.

  b)  The control module closes the gas valve and 5 seconds 

later, removes power from the blower.

5)  Cycle is completed.

Содержание BTF-80

Страница 1: ...ONS CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE MODEL BTF 80 COMMERCIAL POWER VENT GAS WATER...

Страница 2: ...These shall be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made The installation must conform to these instructions and the local code...

Страница 3: ...at 500 Tennessee Waltz Parkway Ashland City TN 37015 When ordering parts provide complete model and serial numbers see rating plate quantity and name of part desired as listed in Figure 1 Standard har...

Страница 4: ...the air flow required for proper combustion potentially resulting in fire asphyxiation serious personal injury or death Do not cover the gas valve or temperature pressure relief valve Do not allow in...

Страница 5: ...learance of 4 10 cm must be allowed for access to replaceable parts such as the thermostats drain valve and relief valve A top clearance of 24 61 cm should be allowed for blower assembly service Adequ...

Страница 6: ...st be checked for safe operation Make sure that the outside vents on the supply regulators and the safety vent valves are protected against blockage These are parts of the gas supply system not the he...

Страница 7: ...7 FIGURE 3 WARNING VENT HOOD S MAY BE EXTREMELY HOT DURING OPERATION U S HORIZONTAL VENT CLEARANCES CANADIAN HORIZONTAL VENT CLEARANCES...

Страница 8: ...ION CHECK FOR GAS LEAKAGE USE SOAP AND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE DO NOT USE MATCHES CANDLES FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS RELIEF VALVE A NEW...

Страница 9: ...1785 or Cellular Core Schedule 40 DWV ASTM F 891 Schedule 40 CPVC ASTM F 441 orABS ASTM D 2661 pipe The fittings other than the TERMINATION 45 ELBOW should be equivalent to PVC DWV fittings meetingAS...

Страница 10: ...against the wall after installation If the vent pipe is installed up to the wall with a coupling on the end against the wall opening the pipe with the vent terminal can be prepared for gluing before...

Страница 11: ...OWER VENT WIRING SCHEMATIC FIGURE 7 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVIC...

Страница 12: ...e where it exits the roof The total vent system should not exceed the thirty 30 equivalent feet 9 1 equivalent meters of 3 inch pipe or one hundred 100 equivalent feet 30 5 equivalent meters of 4 inch...

Страница 13: ...ing characteristics IMPORTANT NOTE A dauber type applicator should only be used on pipe sizes 2 5 1 cm and below For larger diameter pipe a brush or roller must be used 3 MAKING THE JOINT A Cutting Pi...

Страница 14: ...tting will have a tendency to slide back while the cement is still wet so hold the joint together for about 15 seconds STEP F G Cleanup and joint movement Remove all excess cement from around the pipe...

Страница 15: ...follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM AL...

Страница 16: ...RESPONSE TIME OF CHILDREN AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP OR TO DRAW THEIR OWN BATH WATER NEVER LEAVE A CHILD OR DISABLED PERS...

Страница 17: ...heater for several minutes and check to see if it is venting properly by passing a lit match or paper near the opening of the Air Mixing Box See figure 11 If the draft is proper the match flame will b...

Страница 18: ...oted above If you are having a problem with your water heater before calling for service please refer to the following TROUBLE SHOOTING sections If service becomes necessary contact your dealer instal...

Страница 19: ...r service to outlet Replace switch Replace control harness Replace blower and motor Replace switch Check for low voltage less than 102 vac have service checked and repaired Ifvoltageisabove102vac make...

Страница 20: ...circuit 1 Turn power to the water heater off for 10 seconds and then back on 2 Replace gas control valve Problem with the internal circuit 1 Turn power to the water heater off for 10 seconds and then...