NOTES:

1.

 

Preferred piping diagram.

2.

 

The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system.

3.

 

Service valves are shown for servicing unit. However

, local codes shall govern their usage.

4.

 

The 

Tank 

Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s).

5.

 

The water heater

’s operating thermostat should be set 5 degrees F higher than the 

Tank 

Temperature Control.

SINGLE FL

UE

 - (2 UNITS) 

TWO 

TEMPERA

TURE ONE PRE-HEA

TER/ONE BOOSTER HEA

TER

LEGEND

TEMPER

AT

URE & PRESSURE

RELIEF 

VA

LV

E

PRESSURE RELIEF 

VA

LV

E

CIRCULA

TING PUMP

TA

NK TEMPER

AT

URE CONTRO

L

DRAIN

FULL

 PO

RT 

BAL

VA

LV

E

TEMPER

AT

URE GAGE

WA

TER FLOW SWITC

H

CHECK 

VA

LV

E

W

ARNING: THIS 

DR

AW

ING SHOWS SUGGESTED

PIPING CONFIGUR

AT

ION 

AND OTHER DEVICES;

CHECK WITH LOCAL

 CODES 

AND ORDINANCES

FOR ADDITIONA

REQUIREMENTS.

FINISHED FLOOR

HO

WA

TER

TO

 FIXTURES

HO

WA

TER R

ETURN

HOT

HOT

COLD

HIGH

TEMPERATURE

RETURN

HIGH

TEMPERATURE

OUTLET

COLD WATER SUPPLY

EXPANSION TANK

PIPE T&P TO OPEN DRAIN

PIPE T&P TO OPEN DRAIN

BOOSTER HEATER

Содержание BL-80

Страница 1: ...safety messages could result in death or serious injury This manual must remain with the water heater 500 Tennessee Waltz Parkway Ashland City TN 37015 Low Lead Content WARNING If the information in t...

Страница 2: ...gs for Confined Spaces 13 Outdoor Air Through Two Openings 13 Outdoor Air Through One Opening 13 Outdoor Air Through Two Horizontal Ducts 14 Outdoor Air Through Two Vertical Ducts 14 Air From Other In...

Страница 3: ...hazard what can happen if you do not follow the safety message and how to avoid the risk of injury DANGER WARNING CAUTION CAUTION DANGER indicates an imminently hazardous situation which if not avoide...

Страница 4: ...4 GENERAL SAFETY INFORMATION...

Страница 5: ...you don t follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation op...

Страница 6: ...2 1 1 2 12 1 2 CM 157 6 147 3 74 9 64 1 40 3 10 2 38 7 40 6 5 1 NPT NPT 31 8 Model INPUT RATE F 30 40 50 60 70 80 90 100 110 120 130 140 GPH 246 184 147 123 105 92 82 74 67 61 57 53 C 17 22 28 33 39 4...

Страница 7: ...vicing and proper operation of the water heater Installation of water heater must be accomplished in such a manner that if the tank or any connections should leak flow will not cause damage to the str...

Страница 8: ...per and inefficient operation of the water heater producing carbon monoxide gas in excess of the safe limits This could result in serious injury or death Contact your local gas supplier for any specif...

Страница 9: ...rtain it does not sag thereby obstructing the combustion air flow HARD WATER Where hard water conditions exist water softening or the threshold type of water treatment is recommended This will protect...

Страница 10: ...manufacturer s specifications If a positive lock up regulator is required follow these instructions 1 Positive lock up gas pressure regulators must be rated at or above the input Btu hr rating of the...

Страница 11: ...s not intended for the constant relief of thermal expansion A properly sized thermal expansion tank must be installed on all closed systems to control the harmful effects of thermal expansion Contact...

Страница 12: ...ature Pressure Relief Valve discharge line and 2 the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot If after manually operating th...

Страница 13: ...eater and the risk of fire or explosion may result It can also create a risk of asphyxiation LOUVERS AND GRILLES Thefreeareasofthefreshairopeningsintheinstructionsthatfollowdonot takeintoaccountthepre...

Страница 14: ...e provided with two permanent vertical ducts one commencing within 12 inches 300 mm of the top and one commencing within 12 inches 300 mm of the bottom of the enclosure The vertical ducts shall commun...

Страница 15: ...er heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation explosion or asphyxiation Align the legs of the draft hood with the holes provided Insert...

Страница 16: ...IN INCHES MAXIMUM CAPACITY OF PIPE IN CUBIC FEET PER HOUR LENGTH IN FEET NOMINAL IRON PIPE SIZES INCHES INPUT IN THOUSANDS BTU HR 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 4 10 175 360 680 1400 2100 3960 6300 1...

Страница 17: ...allation shown in the Figures 15 and 16 Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure t...

Страница 18: ...ter several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier SEE FIGURE A DANGER Hotter water increases the risk of scald injury Consult the instructio...

Страница 19: ...r at the water heater Mixing valves are available at plumbing supply or hardware stores see Figure 6 Follow manufacturer s instructions for installation of the valves Before changing the factory setti...

Страница 20: ...See Condensation in this section OPERATIONAL CONDITIONS SMELLY WATER In each water heater there is installed at least one anode rod for corrosion protection of the tank Certain water conditions will c...

Страница 21: ...replaced At least once a year a visual inspection should be made of the main burner and pilot burner see Figure 19 Inspect burner fl ames through viewport Flames should be very small with a blue haze...

Страница 22: ...ter temperature and usage see chart The higher the water temperature or water usage the more lime deposits are dropped out of the water This is the lime scale which forms in pipes heaters and on cooki...

Страница 23: ...drained before opening cleanout To clean heater through cleanout opening proceed as follows 1 Drain heater 2 Remove outer cover plate from lower side of heater jacket 3 Remove six 6 hex head screws se...

Страница 24: ...er is no longer hot 4 Close the cold water inlet valve to the water heater 5 Connect a hose to the water heater drain valve and terminate it to an adequate drain 6 Open the water heater drain valve an...

Страница 25: ...an condense on the cooler surfaces of the tank Droplets form and drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold I Wa...

Страница 26: ...Gas Control Replace Gas Control PILOT OUTAGE Dirty pilot burner Clean pilot assembly Thermocouple malfunction Replace pilot assembly and or thermocouple Defective Gas Control Replace Gas Control Ther...

Страница 27: ...ocal codes shall govern their usage 4 The Tank Temperature Control should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat s...

Страница 28: ...trol should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature Cont...

Страница 29: ...Control should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature C...

Страница 30: ...ired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE...

Страница 31: ...rature Control should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temper...

Страница 32: ...he pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE 2 UNITS TWO TEMPERATU...

Страница 33: ...33 NOTES...

Страница 34: ...34 NOTES...

Страница 35: ...gas type venting connections combustion air voltage wiring or fusing Failure to follow applicable codes Failure to follow printed instructions Improper installation sizing delivery or maintenance Cla...

Страница 36: ...36 500 Tennessee Waltz Pkwy Ashland City TN 37015 Technical Support 800 527 1953 Parts 800 433 2545 www hotwater com Copyright 2014 A O Smith Corporation All rights reserved...

Отзывы: