NEED HELP? GIVE US A CALL
833.232.9711
NEED HELP? GIVE US A CALL
833.232.9711
9
Check for leaks and proper installation: Turn on
cold water. Place towel under filter unit and check
for leaks. Allow water to run 10 minutes to flush.
Note: Never use oils to lubricate the O-rings;
O-rings come pre-lubricated.
Unit installation: Select a space under sink for filter
unit that is at least 3" from bottom of your cabinet
and allows for easy access to cold water supply and
filter replacements. Use mounting holes located on
back of unit to pencil in the wall screw placements.
Note: Center to center hole distance is 2.55".
Use a 7/32" drill bit to drill holes for plastic anchors.
Carefully tap anchors into the drilled hole with a
hammer. Mount unit to the wall with screws. Pull
protective plastic strip from the battery compartment.
The red LED should flash and beep five (5) times to
indicate that battery is installed correctly.
Faucet connection: Connect outlet hose
to base of faucet by sliding chrome nut
onto tube followed by the white collar.
Place white insert into the end
of tube. Press tube against the faucet
base and slide the nut and collar up to
the threads. Use wrench to ensure seal
is sufficiently tight.
INSTALLATION GUIDE
Connect supply lines: Insert tubing from
tee fitting into the inlet side and insert
tubing from faucet into the outlet side.
Use diagram to mark tubing depth to
ensure they are completely inserted.
It is VERY IMPORTANT to insert tubing
completely so leaking does not occur.
Faucet Installation: Install as shown.
Tighten faucet nut (I) to secure
faucet to sink.
TIPS
Insert tubing all the way (.95") to prevent leaking.
Wet end of tubing for an easy install into inlets and outlets.
Cut excess tubing to prevent crimping, kinks, loops or folds.
2
3
A
Attach one white poly tube to the brass tee, and slide compression
nut onto the tubing (with threads of nut facing end of the tube).
Next, slide the plastic sleeve onto the tube. Place brass insert into
the opening of tube. Push tip of the tube into opening of the brass
tee. While holding the tube in place inside the brass tee, tighten
compression nut to compress plastic sleeve and create a seal.
1
2
3
Depth to insert 2 stage tubing
Diagram is actual size.
Note: Avoid over-tightening.
Note: Avoid over-tightening.
Turn off and disconnect cold water supply.
Attach threaded ends of supplied brass
tee to cold water supply line and shut-off
valve; tighten using an adjustable wrench.
A
B
C
D
E
H
F
G
I
1
2
3
5
J
D
L
4
6
7
10
Attach each sump to bottom of the unit
housing. Align connection points, push
sump up and turn to the right.
Note: Ensure the sump is locked in.
8