background image

NEED HELP? GIVE US A CALL

 833.232.9711

NEED HELP? GIVE US A CALL

 833.232.9711

9

Check for leaks and proper installation: Turn on 
cold water. Place towel under filter unit and check 
for leaks. Allow water to run 10 minutes to flush.

Note: Never use oils to lubricate the O-rings; 
O-rings come pre-lubricated.

Unit installation: Select a space under sink for filter 
unit that is at least 3" from bottom of your cabinet 
and allows for easy access to cold water supply and 
filter replacements. Use mounting holes located on 
back of unit to pencil in the wall screw placements.

Note: Center to center hole distance is 2.55".

Use a 7/32" drill bit to drill holes for plastic anchors. 
Carefully tap anchors into the drilled hole with a 
hammer. Mount unit to the wall with screws. Pull 
protective plastic strip from the battery compartment. 
The red LED should flash and beep five (5) times to 
indicate that battery is installed correctly.

Faucet connection: Connect outlet hose 
to base of faucet by sliding chrome nut 
onto tube followed by the white collar. 
Place white insert into the end  
of tube. Press tube against the faucet 
base and slide the nut and collar up to 
the threads. Use wrench to ensure seal  
is sufficiently tight. 

INSTALLATION GUIDE

Connect supply lines: Insert tubing from 
tee fitting into the inlet side and insert 
tubing from faucet into the outlet side. 
Use diagram to mark tubing depth to 
ensure they are completely inserted. 
It is VERY IMPORTANT to insert tubing 
completely so leaking does not occur.  

Faucet Installation: Install as shown. 
Tighten faucet nut (I) to secure 
faucet to sink.

TIPS

Insert tubing all the way (.95") to prevent leaking.  
Wet end of tubing for an easy install into inlets and outlets.
Cut excess tubing to prevent crimping, kinks, loops or folds.

2

3

A

Attach one white poly tube to the brass tee, and slide compression 
nut onto the tubing (with threads of nut facing end of the tube). 
Next, slide the plastic sleeve onto the tube. Place brass insert into 
the opening of tube. Push tip of the tube into opening of the brass 
tee. While holding the tube in place inside the brass tee, tighten 
compression nut to compress plastic sleeve and create a seal.

1

2

3

Depth to insert 2 stage tubing

Diagram is actual size.

Note: Avoid over-tightening.

Note: Avoid over-tightening.

Turn off and disconnect cold water supply. 

Attach threaded ends of supplied brass 
tee to cold water supply line and shut-off 
valve; tighten using an adjustable wrench.

A

B

C

D

E

H

F

G

I

1

2

3

5

J

D

L

4

6

7

10

Attach each sump to bottom of the unit 
housing. Align connection points, push 
sump up and turn to the right. 

Note: Ensure the sump is locked in.

8

Содержание AOW-2000

Страница 1: ...NER S MANUAL Use this owner s manual to reference installation troubleshooting and filter replacement information If you need help or have a question we ve got you covered Give us a call at 833 232 97...

Страница 2: ...AOW 2000 2 STAGE UNDER SINK Sistema bajo el fregadero de 2 etapas Owner s Manual El manual del proprietario...

Страница 3: ...ve us a call at 833 232 9711 BOX CONTENTS 1 Tools recommended for installation Variable speed drill w 7 32 bit Adjustable wrench Measuring tape Bucket Phillips head screwdriver Hammer Faucet may be mo...

Страница 4: ...ALLATION GUIDE Connect supply lines Insert tubing from tee fitting into the inlet side and insert tubing from faucet into the outlet side Use diagram to mark tubing depth to ensure they are completely...

Страница 5: ...1 1 trichloroethane 0 2 0 084 0 0046 95 1 1 2 trichloroethane 0 005 0 150 0 0005 99 trichloroethylene 0 005 0 180 0 0010 99 trihalomethanes THMs Influent Unfiltered Effluent Filtered Percent Reductio...

Страница 6: ...e covered product and send it to you upon payment of 9 50 for shipping and handling per incident How to get service To receive service under this warranty you must contact A O Smith at 833 232 9711 or...

Страница 7: ...espu s el collar n blanco para conectar la manguera de salida a la base de la llave Coloque el inserto blanco en el extremo del tubo Presione el tubo contra la base de la llave y deslice la tuerca y e...

Страница 8: ...pliegues 1 2 3 Profundidad para insertar las tuber as de 2 pasos El diagrama tiene la dimensi n real 6 10 8 Fije cada sumidero en la parte posterior de la carcasa de la unidad Alinee los puntos de con...

Страница 9: ...ca en las normas NSF ANSI 42 53 401 y P473 13 Hoja de datos de rendimiento del filtro de agua para debajo del mostrador de A O Smith Modelos Repuesto Rango de presi n de funcionamiento Capacidad nomin...

Страница 10: ...taminant reduction performance system damage or failure Use of parts from other manufacturers will also void your warranty Please visit www aosmith com wholesale for replacement parts Installation mus...

Отзывы: