Instruction manual ADMR
29
is
3.9.3
Fitting the flue damper
The following parts can be found in the separate package for the flue damper,
supplied with the appliance: the complete assembled flue damper (1), a
mounting plate (2) with hole for the flue damper shaft, and fastening screws.
You may fit the flue damper in either the left or the right hand side of the draught
diverter.
Flue damper
1. Take the flue damper (1) out of the packaging.
2. There are two cover plates on the draught diverter, one on each side.
Unscrew these.
3. Fit the mounting plate (2) with shaft hole, supplied with the flue damper, on
one side of the draught diverter.
4. Slide the flue damper, as shown in the figure, into the other opening in
Note
See
Electrical connection
for the flue damper electrical connections.
Legend
1 flue damper
2 mounting plate
1
2
IMD-0124 R1
Содержание ADMR-40
Страница 4: ...4 Instruction manual ADMR gis...
Страница 8: ...Table of contents 8 Instruction manual ADMR...
Страница 12: ...Introduction 12 Instruction manual ADMR 1 gis...
Страница 38: ...Installation 38 Instruction manual ADMR 3 is...
Страница 56: ...Shutting down 56 Instruction manual ADMR 10 gis...
Страница 64: ...Main menu 64 Instruction manual ADMR 11 gis...
Страница 78: ...is Instruction manual ADMR 78...
Страница 80: ...Maintenance frequency 80 Instruction manual ADMR 14 is...
Страница 86: ...Performing maintenance 86 Instruction manual ADMR 15 s...
Страница 94: ...Appendices 94 Instruction manual ADMR 17 is...
Страница 96: ...Instruction manual ADMR 96...