2
The illustration shows a typical gas-fired commercial gas power burner, tank-type
water heater. The principal components of the heater are shown and identified
here. By referring to the plate on the heater jacket the unit may be identified in the
specifications presented in Table 1 and 2.
FEATURES AND SPECIFICATIONS
Model Designator: Sample ***81-140NEA
N = Natural Gas
*** = Letter designator
E = 3 Year Warranty
81 = Gallon Capacity
A = ASME Construction
140 = 140,000 BTU/HR imput
TABLE 2 - MODEL ENERGY CONSUMPTION AND PERFORMANCE DATA
STORAGE
MAXIMUM
MODELS
CAPACITY
IMPUT RATING
RECOVERY RATE
RECOVERY RATE
AMPERES
U.S. GALLONS
BTU/HR.
GPH@100°F RISE
GPH@140°F RISE
120V, 60Hz, 1Ø
***81-140
81
140,000
136
97
5
***81-199
81
199,000
193
138
5
***81-270
81
270,000
262
187
5
***81-370
81
370,000
359
256
5
TABLE 1 - NOMINAL MODEL DIMENSIONS AND WEIGHTS
MODELS
A
B
C
D
E
G
H
J
GAS APPROX. SHIP.
IN
OUT
WT. (LBS.)
ASME STD.
***81-140
74 3/4
65
26 3/4
6
21 3/8
27 3/4
38
85 1/4
1/2 658 556
1 1/2
1 1/2
***81-199
74 3/4
65
26 3/4
6
21 3/8
27 3/4
38
85 1/4
1/2 635 545
1 1/2
1 1/2
***81-270
74 3/4
65
26 3/4
8
21 3/8
27 3/4
38
85 1/4
3/4 632 547
1 1/2
1 1/2
***81-370
74 3/4
65
26 3/4
8
21 3/8
27 3/4
38
85 1/4
3/4 731 634
1 1/2
1 1/2
Содержание ***81-140
Страница 11: ...11 WIRING FOR 81 140 THRU 81 370 FIGURE 9 SCHEMATIC DIAGRAM WIRING DIAGRAM...
Страница 26: ...26 MODELHSG200 400GASBURNER...
Страница 28: ...28...