OPERATING INSTRUCTIONS FOR I.I.D. MODELS

The I.I.D. models have an automatic intermittent spark ignition system, figure 3, mounted on the jacket at the front of the heater which
ignites the pilot gas whenever system controls call for heat.

Start the unit in accordance with the instructions on the operating label attached to the heater.  These instructions are repeated in the
following.

1. SET THE THERMOSTAT TO LOWEST SETTING.
2. TURN OFF ALL ELECTRIC POWER TO THE APPLIANCE IF SERVICE IS TO BE PERFORMED.
3. TURN GAS VALVE CONTROL KNOB CLOCKWISE 

 TO “OFF”. REFER TO STEP 5 OF “OPERATING INSTRUCTIONS”

     ABOVE.

A.

THIS APPLIANCE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY  LIGHTS THE
PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.

B.

BEFORE OPERATING SMELL ALL AROUND THE
APPLIANCE AREA FOR GAS . BE SURE TO SMELL
NEXT TO THE FLOOR BECAUSE SOME GAS IS
HEAVIER THAN AIR AND WILL SETTLE ON THE
FLOOR.

WHAT TO DO IF YOU SMELL GAS
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRIC SWITCH

DO NOT USE ANY PHONE IN YOUR BUILDING.

• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM

A NEIGHBOR’S PHONE. FOLLOW THE GAS
SUPPLIER’S INSTRUCTIONS.

• IF YOU CANNOT REACH YOUR GAS SUPPLIER,

CALL THE FIRE DEPARTMENT.

C.

USE ONLY YOUR HAND TO TURN THE GAS
CONTROL KNOB . NEVER USE TOOLS. IF THE KNOB
WILL NOT TURN BY HAND, DON’T TRY TO REPAIR
IT. CALL A QUALIFIED SERVICE TECHNICIAN.
FORCE OR ATTEMPTED REPAIR MAY RESULT  IN A
FIRE OR EXPLOSION.

D.

DO NOT USE THIS APPLIANCE IF ANY PART HAS
BEEN UNDER WATER. IMMEDIATELY CALL  A
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE
APPLIANCE AND TO REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDER WATER.

E.

DO NOT OPERATE APPLIANCE UNLESS UNIT IS
FILLED WITH WATER AND INLET LINES AFTER
FULLY OPEN.

WARNING:  IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

1.

STOP! READ THE SAFETY INFORMATION
ABOVE ON THIS LABEL.

2.

SET THERMOSTAT TO LOWEST SETTING.

3.

TURN OFF ALL ELECTRIC POWER TO THE
APPLIANCE.

4.

THIS APPLIANCE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY  LIGHTS THE
PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.

5.

TURN GAS VALVE CONTROL KNOB CLOCKWISE 
TO “OFF” (FIG. A) A SLIGHT INDENT CAN BE FELT
IN THE “OFF” POSITION.

6.

WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS.
THEN SMELL FOR GAS, INCLUDING NEAR THE
FLOOR. IF YOU THEN SMELL GAS.

STOP! FOLLOW “B” IN THE SAFETY

          INFORMATION ABOVE IN THIS LABEL.

IF YOU DON’T SMELL GAS. GO TO NEXT
STEP.

 7.

TURN GAS CONTROL KNOB COUNTERCLOCKWISE

  TO “ON” (FIG. B) UNTIL KNOB SNAPS INTO “ON”

POSITION.

 8.

TURN ON ALL ELECTRICAL POWER TO THE
APPLIANCE.

 9.

SET THERMOSTAT TO DESIRED SETTING. PILOT
WILL BE IGNITED BY ELECTRONIC SPARK. WHEN
PILOT IGNITION IS SENSED, THE MAIN BURNERS
WILL IGNITE.

10.

IF MAIN BURNER FAILS TO IGNITE, REMOVE
BURNER ACCESS DOOR AND FOLLOW SMALL
METAL TUBE FROM GAS VALVE TO PILOT. REPEAT
STEPS 2 THRU 9. MAKE SURE PILOT IS BURNING.
IF PILOT FAILS TO IGNITE, CHECK FOR PILOT
IGNITION SPARK.

IF APPLIANCE WILL NOT OPERATE, FOLLOW THE
INSTRUCTIONS “TO TURN OFF GAS TO
APPLIANCE” AND  CALL YOUR  SERVICE
TECHNICIAN OR GAS SUPPLIER.

FOR YOUR SAFETY READ BEFORE OPERATING

TO TURN OFF GAS TO APPLIANCE

OPERATING INSTRUCTIONS

HONEYWELL VR8304P GAS CONTROL

Содержание 160M

Страница 1: ...structions are not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity o...

Страница 2: ...0 3 4 527 E 5 1 2 140 5 1 2 140 5 1 2 140 5 1 2 140 F 10 254 10 254 10 254 10 254 G 11 13 16 300 11 13 16 300 11 13 16 300 11 13 16 300 H 6 152 7 178 7 178 7 178 J 26 11 16 678 26 11 16 678 26 11 16 6...

Страница 3: ...io M3B 2R3 Canada TABLE OF CONTENTS ROUGH IN DIMENSIONS 2 FOREWORD 3 GENERAL SAFETY INFORMATION 3 Precautions 3 4 Grounding Instructions 4 Chemical Vapor Corrosion 4 Liquid Petroleum Models 4 High Alt...

Страница 4: ...F THE BURNER ORIFICE IN ACCORDANCE WITH SECTION 8 1 2 OF THE NATIONAL FUEL GAS CODE ANSI Z223 1 FOR CANADIAN INSTALLATIONS CONSULT CANADIAN INSTALLATION CODES AND CAN CGA B149 FAILURE TO REPLACE THE O...

Страница 5: ...t remove the protector switch cover and push the reset button after the coil surface temperature cools to less than 2000 F 93 3 C FIGURE 2 DO NOT RESET THIS SWITCH WITHOUT PERFORMING THE SYSTEM CHECKS...

Страница 6: ...lectrical requirements of the system Typically the thermostat should have motor full load and locked rotor current ratings which exceed the total amount of current required to drive the pump s control...

Страница 7: ...s exactly when inserting this switch into a pipe tee This is necessary in order to assure positive action of the switch with water flow Once the minimum flow rate Table 5 through the heater is reached...

Страница 8: ...ADJACENT TO THE HEATER OPEN CONTAINERS OF FLAMMABLE MATERIAL SHOULD NOT BE STORED OR USED IN THE SAME ROOM WITH THE HEATER For appliance installation in locations with elevations above 2 000 feet 600M...

Страница 9: ...ted A special vent cap may be required FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR CONTAMINATION AND UNSAFE CONDITIONS If the back draft cannot be corrected by the normal methods or if a suitable dra...

Страница 10: ...ent relief valve operation This is not a warranty failure An expansion tank may be necessary in the cold water supply to alleviate this situation Contact the local plumbing authority WATER LINE CONNEC...

Страница 11: ...TEMPERATURE ONLY FIGURE 7 DANGER TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 19 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY T...

Страница 12: ...SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 19 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VA...

Страница 13: ...TTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 19 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCA...

Страница 14: ...HEATER AND ITS MANUAL GAS SHUTOFF VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1 2 PSIG THE GAS SUPPLY LINE MUST BE CAPPED WHEN NO...

Страница 15: ...connection All piping diagrams include an electrical wiring diagram to assist the installer in properly wiring of the additional components required to assure correct system operation Figures 11 and...

Страница 16: ...16 ELECTRICAL WIRING DIAGRAMS FOR THE HW 120M 160M AND 200M WATER HEATERS I I D SYSTEM PROPANE FIGURE 12 NOTES...

Страница 17: ...Y PERSONS EXPERIENCED IN THIS TYPE GAS SERVICE TO AVOID RISK OF FIRE OR EXPLOSION PURGE DISCHARGE MUST NOT ENTER CONFINED AREAS OR SPACES WHERE IGNITION CAN OCCUR THE AREA MUST BE WELL VENTILATED AND...

Страница 18: ...SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER E DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED WITH WATER AN...

Страница 19: ...to OFF See page 18 2 Attach a pressure gauge or a manometer to the outlet pressure tap figure 14 and refer to table 3 for correct manifold pressure 3 Fire the heater by turning the gas valve control...

Страница 20: ...arp metal objects to clean blocked orifices as they will damage the soft brass orifice Remove any soot or carbon deposits with a rag making sure to remove any lint left on burner by vacuuming again MA...

Страница 21: ...ontrol is out of calibration replace control AUTOMATIC GAS SHUTOFF CONTROL The automatic gas shutoff control fig 1 is an automatic device which is wired in series with the gas valve and intermittent i...

Страница 22: ...pressure regulator cannot be adjusted to correct pressure with sufficient gas pressure at the valve replace with new gas valve RELIEF VALVE At least twice a year the system relief valves should be ch...

Страница 23: ...upper deliming tee Open drain cock and drain heater Install standpipe in lower deliming tee or in tee from which pressure relief valve has been removed 4 Close drain valve 5 Slowly pour 3 gallons of...

Страница 24: ...burner shut remain on differential wide tank water temperature off With thermal Tank temperature control Replace balancer pump off defective delay of approx imately 2 minutes System wiring is incorre...

Страница 25: ...y plugged into module Is green ground wire firmly attached to mounting screw and GND terminal on module Ensure ground strap is the closest metal to the igniter sensor rod electrode to prevent the spar...

Страница 26: ...l on module Is pilot burner ignition cable in good condition not brittle burnt or cracked Ensure ground strap is the closest metal to the igniter sensor rod electrode to prevent the spark from shortin...

Страница 27: ...d in good condition not broken or cracked Are the igniter sensor rod in good condition not worn corroded sooted or damaged Replace ignition module Correct the situation by consulting the installation...

Страница 28: ...r charges for service removal repair or reinstallation of the water heater or any component part b Shipping delivery handling and administrative charges for forwarding the new heater or replacement pa...

Отзывы: