6
RS-232 & Telnet Commands
RS-232 & Telnet Commands
COMMAND
DESCRIPTION AND PARAMETERS
GET FW VER
8
Show the unit’s current firmware version.
SET FACTORY DEFAULT
8
Reset the unit to the factory defaults.
SET IN A EDID N1
8
Set the EDID to be used by the HDMI input.
Available values for
N1
:
1 [FHD/2CH]
2 [FHD/MCH]
3
[User EDID]
15
[Sink EDID]
GET IN A EDID
8
Show the EDID currently being used by the HDMI input.
SET OUT A MUTE N1
8
Enable or disable audio/video mute on the HDMI output.
Available values for
N1
:
ON
[A/V Mute enabled]
OFF
[A/V Mute disabled]
GET OUT A MUTE
8
Show the current audio/video mute state of the HDMI output.
SET OUT A AUDIO MUTE N1
8
Enable or disable the audio-only mute on the HDMI output.
Available values for
N1
:
ON
[Mute enabled]
OFF
[Mute disabled]
GET OUT A AUDIO MUTE
8
Show the current audio mute state of the HDMI output.
GET OUT A SYNC STATUS
8
Show the current sync state of the HDMI output.
SET OUT A OSD INFO N1
8
Enable or disable the info OSD for the HDMI output.
Available values for
N1
:
ON
[Enable OSD]
OFF
[Disable OSD]
GET OUT A OSD INFO
8
Show the current info OSD state for the HDMI output.
SET OUT A OSD INFO TIMEOUT N1
8
Set the info OSD’s timeout value for the HDMI output (in seconds).
N1
= 0 ~ 100
[Timeout length]
GET OUT A OSD INFO TIMEOUT
8
Show the current info OSD’s timeout value for the HDMI output.
SET OUT A OSD INFO VPOSITION N1
8
Set the vertical position of the OSD on the HDMI output.
N1
= 0 ~ 100
[Vertical position]
GET OUT A OSD INFO VPOSITION
8
Show the current vertical position of the OSD on the HDMI output.
SET OUT A OSD INFO HPOSITION N1
8
Set the horizontal position of the OSD on the HDMI output.
N1
= 0 ~ 100
[Horizontal position]
GET OUT A OSD INFO HPOSITION
8
Show the current horizontal position of the OSD on the HDMI output.
GET MAC ADDR
8
Show the unit’s MAC address.
SET IP MODE N1
8
Set the IP address assignment mode.
Available values for
N1
:
0
[Static IP mode]
1
[DHCP mode]
GET IP MODE
8
Show the current IP address assignment mode.
GET IPCONFIG
8
Show the unit’s current IP configuration information.
SET IP ADDR N1
8
Set the unit’s static IP address.
N1
= x.x.x.x
[x = 0 ~ 255, IP address]
GET IP ADDR
8
Show the unit’s current IP address.