A-Neuvideo ANI-H-KIT Скачать руководство пользователя страница 20

18

RS-232 & Telnet Commands

COMMAND

DESCRIPTION OF PARAMETER

SET AUTOMATION EVENT N1 CEC 

WAIT N2 SEC 

Set the length of time to wait after an Automation Event’s CEC response has been 

activated before ANY other Automation Event can be detected.
Available values for 

N1: 

[Power on]

[Out A source active]

[Out A source lost]

N2

 = 1 ~ 300 

[Wait time in seconds]

NOTE: 

If both an RS-232 and CEC event is activated by the same Automation Event, 

the longer of the 2 wait times will be used.

GET AUTOMATION EVENT N1 CEC 

WAIT 

Show the wait time for the specified Automation Event’s CEC response.

Available values for 

N1: 

[Power on]

[Out A source active]

[Out A source lost]

SET AUTOMATION EVENT N1 CEC 

COMMAND N2 

Set the CEC command to send when the specified Automation Event is activated.

Available values for 

N1:                                  

Available values for 

N2:

[Power on]

[Out A source active]

[Out A source lost]

[CEC power off]

[CEC power on]

[CEC active source]

GET AUTOMATION EVENT N1 CEC 

COMMAND 

Set the RS-232 operation mode of the unit.

Available values for 

N1:

[Console Commands]

2 [Control]

GET UART 1 MODE 

Show the current RS-232 operation mode.

SET UART 1 BAUDRATE N1 

Set the RS-232 baud rate.

Available values for 

N1:

4800 

[Baud rate]

7200 

[Baud rate]

9600 

[Baud rate]

14400  [Baud rate]

19200  [Baud rate]
38400  [Baud rate]
57600  [Baud rate]
115200  [Baud rate]

GET UART 1 BAUDRATE 

Show the current RS-232 baud rate.

SET UART 1 STOP BIT N1 

Set the number of RS-232 stop bits to use.

N1

 = 1 ~ 2

GET UART 1 STOP BIT 

Show the current RS-232 stop bits setting.

SET UART 1 DATA BIT N1 

Set the number of RS-232 data bits to use.

N1

 = 5 ~ 8

GET UART 1 DATA BIT 

Show the current RS-232 data bits setting.

SET UART 1 PARITY N1 

Set the parity value for RS-232.

Available values for 

N1:

0 [None]
1 [Odd]
2 [Even]

GET UART 1 PARITY 

Show the current RS-232 parity setting.

NOTE: 

Commands will not be executed unless followed by a carriage return. Commands are not case-sensitive.

A

  

NEU

VIDEO

Содержание ANI-H-KIT

Страница 1: ...ANI H KIT ANI H R4K HDMI over HDBaseT Receiver w IR RS 232 PoH PSE LAN Receiver ANI HV WP4K 4K UHD HDMI VGA over HDBaseT w Signal Event Automation 1 Gang Wallplate Switcher INSTRUCTION MANUAL A NeuVid...

Страница 2: ...on 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat prod...

Страница 3: ...smitter PD may be powered locally or via 48V PoH from a compatible HDBaseT Receiver PSE which allows for greater flexibility in installations The unit can be controlled via the front panel button with...

Страница 4: ...C Power Adaptor Power Cord Users Guide APPLICATIONS Household entertainment sharing and control Lecture halls auditoriums and classroom Houses of worship Conference rooms and boardrooms Hotel event sp...

Страница 5: ...signal event automation via RS 232 or CEC w compatible Receiver USB port supports firmware update and powering of 5V 500mA devices Front panel LEDs indicate HDCP mode input source and power Controlla...

Страница 6: ...d Resolutions 480i 60Hz 4K 60Hz 4 2 0 8 bit VGA 60Hz WUXGA 60Hz RB HDMI Cable Length 10M 1080p 60Hz 12 bit 5M 4K 60Hz 4 4 4 8 bit CAT5e 6 Cable Length 100M 1080p 60Hz 12 bit 70M 4K 60Hz 4 2 0 8 bit IR...

Страница 7: ...t input Green indicates Follow Display mode orange indicates Follow Source mode off indicates HDCP is disabled SRC LED This LED indicates which source is currently selected Green indicates the HDMI in...

Страница 8: ...other properly y DC 48V Plug the 48V DC power adapter into this port and connect it to an AC wall outlet for power u IR1 BLASTER Connect to the supplied IR Blaster cable for IR signal transmission Pla...

Страница 9: ...ssignment Pin Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 115200bps Data Bit 8 bits Parity None Flow Control None Stop Bit 1 NOTE R...

Страница 10: ...CP server To switch to DHCP mode please select DHCP from the IP mode drop down then click Save followed by Reboot WebGUI Hotkey Once you are satisfied with the network settings you may use them to con...

Страница 11: ...e to confirm and activate any changes Auto Mode Enable or disable the auto input switching mode Audio Route Control the audio used when the HDMI input is active Selecting Bypass will use the HDMI sign...

Страница 12: ...Available CEC commands are Power Off Turn off the connected HDMI display device Power On Turn on the connected HDMI display device Active Source Force the connected HDMI display device to switch to t...

Страница 13: ...nected PC 3 EDID Mode This dropdown controls how EDIDs are assigned to the unit s Inputs All Selecting this will allow the assignment of a single EDID to all Inputs simultaneously Appoint Selecting th...

Страница 14: ...Gateway can be set manually or DHCP can be enabled for automatic IP Configuration if your local network supports it Click on Save to confirm and activate any changes made to these settings Note If th...

Страница 15: ...es and Searching for required files When complete the Telnet client should be installed in Windows In Mac OS X Click Go Applications Utilities Terminal Once in the Command Line Interface CLI type teln...

Страница 16: ...SET NETMASK N1 Set the netmask address N1 X X X X X 0 255 GET NETMASK Show the current netmask SET GATEWAY N1 Set the gateway address N1 X X X X X 0 255 GET GATEWAY Show the current gateway SET IN N1...

Страница 17: ...vailable values for N1 ON All mode OFF Appoint mode GET ALL IN EDID MODE Show the current state of the EDID assignment mode SET ALL IN EDID N1 Set the EDID to use when set to All mode Available values...

Страница 18: ...olor bar SET FREERUN A TYPE Show the current freerun display color GET FREERUN LIST List all available freerun colors GET AUTOMATION EVENT LIST List all Automation Event types SET AUTOMATION EVENT N1...

Страница 19: ...characters GET AUTOMATION EVENT N1 UART COMMAND Show the RS 232 command string to be sent when the specified Automation Event is activated Available values for N1 1 Power on 2 Out A source active 3 Ou...

Страница 20: ...3 Out A source lost 1 CEC power off 2 CEC power on 3 CEC active source GET AUTOMATION EVENT N1 CEC COMMAND Set the RS 232 operation mode of the unit Available values for N1 1 Console Commands 2 Contro...

Страница 21: ...19 w allplate CONNECTION DIAGRAM Connection Diagram A NEUVIDEO...

Страница 22: ...20 receiver CONNECTION DIAGRAM Connection Diagram A NEUVIDEO...

Страница 23: ...366x768 60 60 RB P P P 1440x900 60 60 RB P P P 1600x1200 60 P P P 1680x1050 60 60 RB P P P 1920x1200 60 RB P P P SUPPORTED TV RESOLUTION HZ HDMI INPUT VGA INPUT HDBASET OUTPUT 720 480p 60 P P P 720 57...

Страница 24: ...100M 230 ft 70M CAT7 328 ft 100M 328 ft 100M Full HD Video 1080p Up to 1080p 60Hz 12 bit color Data rates lower than 5 3Gbps or below 225MHz TMDS clock Ultra HD Video 4K 4K 24 25 30Hz 4K 50 60Hz YUV...

Страница 25: ...60 P P 1080i 50 60 P P 1080p 50 60 P P 1080p 24 25 30 P P 3840x2160p 24 25 30 P P 4096x2160p 24 P P 4096x2160p 50 60 4 2 0 P P Cable Specifications CABLE TYPE CABLE LENGTH SUPPORTED VIDEO FORMAT CAT5e...

Страница 26: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 27: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 28: ...tate of Texas United States of America A NeuVideo makes no representation that materials pertaining to the Product are appropriate or available for use in other locations other than the shipping addre...

Отзывы: