VZN V SERIES

2

P/N 1011079 Rev. J 01/14

OWNER INFORMATION

TABLE OF CONTENTS

IMPORTANT! Keep these instructions for future reference. If the system changes 

 ownership, be sure this manual accompanies the equipment.

Owner Information ...............................................................2

General............................................................................... 2
Warranty Information .......................................................... 2
Service/Technical Assistance ............................................. 3

Important Safety Information ..............................................4
Specifications .......................................................................6

Dimensions......................................................................... 6
Electrical Ratings ............................................................... 6
Replacement Cartridges .................................................... 6
Electrical Cord & Plug Configurations ................................ 6

Performance Data Sheet ......................................................7

Filter Cartridge Capacities.................................................. 7
Performance Claims for Percent Reduction....................... 7

Operation ...............................................................................8

Overview ............................................................................ 8
Manual Flushing ................................................................. 8

Installation .............................................................................9

Unpacking .......................................................................... 9
Equipment Setup ................................................................ 9
Mounting the System ....................................................... 10
Drain Valve Connection .....................................................11
Rinse Valve Connection ................................................... 12

System Inlet Connection .................................................. 12
Filtered Water Permeate Outlet Connection .................... 12
Inlet Water Plumbing ........................................................ 12
Installing a Bypass ........................................................... 13
Starting the Controller ...................................................... 13
Rinsing the Ultra Filter Cartridge...................................... 13
Sanitizing the System and Lines ...................................... 14
Rinsing the Carbon Element and TAC Cartridge ............. 14

Maintenance ........................................................................15

Replacing the Ultra Filter Cartridge.................................. 15
Rinsing and Replacing the Carbon Element .................... 16
Rinsing and Replacing the TAC Cartridge  
(VZN-441V-T5 ONLY) ...................................................... 17
System Sanitization .......................................................... 17
Changing the Interval Setting ........................................... 18
Resetting the Timer Program ........................................... 18
Check Permeate Tank Air Pre-Charge ............................. 18

Troubleshooting .................................................................19
Replacement Parts .............................................................20
Notes....................................................................................23
Limited Warranty ................................................................24

General

The VZN system is an innovative filtration system that uses 

proprietary multi-bore hollow fiber membranes as well as a 

carbon element to provide the latest innovation in filtration 

technology.
This manual provides the safety, installation, and  

operating procedures for the VZN water filtration system. All 

information contained in this manual should be read prior to 

installing and operating the system.  Your VZN system is man-

ufactured from the finest materials available and is assembled 

to strict quality standards. This system has been tested at the 

factory to ensure dependable trouble-free operation. 

Warranty Information

Please read the full text of the Limited Warranty in this  

manual.
If the system arrives damaged, contact the carrier immediate-

ly and file a damage claim with them. Save all packing materi-

als when filing a claim. Freight damage claims are the respon-

sibility of the purchaser and are not covered under warranty.
The warranty does NOT extend to:
 

•  Damages caused in shipment or damage as result of 

improper use.

 

•  Installation of electrical service.

 

•  Normal maintenance as outlined in this manual.

 

•  Malfunction resulting from improper maintenance.

 

•  Damage from moisture leaking into electrical  

components.

 

•  Damage from tampering with, removal of, or changing 

any preset control or safety device.

Содержание vizion VZN V Series

Страница 1: ...VZN 441V http tiny cc ajaVZN441V System Tested and Certified by NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate...

Страница 2: ...Check Permeate Tank Air Pre Charge 18 Troubleshooting 19 Replacement Parts 20 Notes 23 Limited Warranty 24 General The VZN system is an innovative filtration system that uses proprietary multi bore ho...

Страница 3: ...lumn and have it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the righ...

Страница 4: ...ll electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS...

Страница 5: ...ion in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping Mechan...

Страница 6: ...00 240 10 08 50 60 VZN 441V T5 9700751 100 240 10 08 50 60 Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adapto...

Страница 7: ...The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF...

Страница 8: ...ebris collecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE Do NOT unplug the power cord or turn off the sys tem during Flush Mode If there is a power outage or the sy...

Страница 9: ...lug on the power cord must match the appropriate outlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the s...

Страница 10: ...ttom mount ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and level to attach the Mo...

Страница 11: ...s flow rate is dependent on the inlet water pressure inlet pipe size and system The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops The...

Страница 12: ...Inlet has a 3 4 NPT male thread at the Inlet Valve Figure 6 Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for...

Страница 13: ...d wait for five minutes to flush out any remaining air 12 Close the Rinse Ball Valve and disconnect the garden hose 13 Press the FLUSH button to open the Drain Valve Repeat six times to ensure any rem...

Страница 14: ...pen the Inlet Valve Allow the pipe to flush until all debris is removed Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contam ination that may have occurred durin...

Страница 15: ...ght coating of lubricant to the inside cen ter tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer t...

Страница 16: ...ning the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element...

Страница 17: ...d or missing 7 Lubricate the O ring with an approved food grade lubricant and install into the TAC Housing 8 Install the new TAC Cartridge into the TAC Hous ing with the arrow on the cartridge pointin...

Страница 18: ...d 4 The permeate tank should have a pressure of 28 31 PSI To add pressure to the permeate tank use a manual bicycle tire pump or other source of compressed air To release pressure from the permeate ta...

Страница 19: ...efective Clean or replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Car...

Страница 20: ...VZN V SERIES 20 P N 1011079 Rev J 01 14 REPLACEMENT PARTS 2 35 3 31 16 11 4 5 6 7 7 8 9 10 13 19 17 18 23 23 22 34 15 36 32 12 14 30 33 25 24 28 14 20 21 14 29 26 27 8 9 10 1 VZN 441V Systems...

Страница 21: ...ES 21 P N 1011079 Rev J 01 14 2 35 3 31 16 11 4 5 6 7 7 8 9 10 13 19 17 18 23 23 22 34 15 39 32 12 14 30 33 25 24 36 37 25 28 14 20 21 14 29 26 27 24 38 8 9 10 1 REPLACEMENT PARTS continued VZN 441V T...

Страница 22: ...1 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 2190154 Adaptor 1 Stem 1 39 0021666 Flow Regulator Assy 15 gpm 1 40 0700769 Wiring Harness not shown 1 41 2190184 Tee PVC...

Страница 23: ...VZN V SERIES 23 P N 1011079 Rev J 01 14 NOTES...

Страница 24: ...operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Отзывы: