background image

1. Wall
2.  Insulation layer (chimney flue)
3.  Connection / chimney flue
4.  Insulation layer (rear wall)
5.  Convection area
6.  Grid for the inflow of convection air
7.   Concrete slab min. 6 cm (for installation 

a protective ceiling)

8. Ceiling
9.  Insulation layer (floor)
10.  Air supply to the fireplace
11.  surroundings (of the room)
12.  Insulation layer (ceiling)
13.  Grid for extraction of convection air

14.   Protective floor made from fireproof 

material

15.  Insulation layer (sides)
16.  surroundings (of the room)
17.  radiation area
18.  Flammable material
19.  Ventilated radiation protection
20.  Protective wall
21.   Fire protection on the passage through 

the flue channel

22.  Firewall from mineral material
23.   Furniture for flammable materials at 

a distance of min 5 cm from the wall of 
the surroundings 

Convection area 

-    If the hot-air jacket is not used, then between the fireplace insert and the insulation layer (4, 15) 

there must be a minimum gap of 6 cm on the rear and side areas.

-    The convection area must be insulated from all walls with the exception of walls which form the 

heat-exchange area of the surroundings.

-    The walls, floor and ceiling of the convection area must be clean and resistant to the abrasion. 

flow of convection air from the hot-air jacket

-    All hot convectional piping must consist of form stable non-flammable materials.  
-    When installing a hot-air jacket, the hose for the flow of hot air must be firmly connected 

to the flange of the hot-air jacket and to the input grid.

operation of the air grid (hypocaust)

-    The conventional air circulates in the closed shelling. The heat from the convectional area is 

transferred into the room through the heat-exchange areas of the surroundings.

-    The heat load in the convectional area of the hypocaust is higher than that for the construction 

with air grids. This higher heat load must be taken into account for additional insulation of the 
conventional space. 

-    The size and the construction of the heat-exchange area of the surroundings must correspond 

to the heat output of the insert.

forewall (protection of walls from flammable materials)

-    This is used to protect the walls of the building (20) and consists of mineral material with a 

minimum thickness of 10 cm.

-    The pre-wall may be terminated a minimum of 20 cm above the chimney flue (3). 
-    The forewall is not required to be built when the wall of the building:
  -    is at least 10 cm thick
  -    is constructed from non-flammable materials
  -    is not a load-bearing concrete wall or a reinforced concrete wall

26

Содержание Crystal 3D 50/60

Страница 1: ...Manual of use installation operation www acaminetti factory com...

Страница 2: ...ck metall Schott ROBAX Culimeta Skamol Insert coat made of quality steel in accordance with EN 13229 Insert components manufactured using modern cnc machines 2D Laser and press brakes Insert welded wi...

Страница 3: ...pes of wood 06 2 4 Storage of wood fuel 07 2 5 Recommended dose of fuel 3 DESCRIPTION OF CONTROL ELEMENTS 3 1 Description of control elements 08 3 2 Options for closing the door 4 OPERATION OF FREPLAC...

Страница 4: ...TS 15 10 CHECKING THE PRODUCT 16 11 CORRECT POSITIONING OF THE FIREPLACE 12 TRANSPORT 17 13 POSITIONING THE FIREPLACE INSERT 18 14 REMOVING THE TRANSPORT SECURING 19 15 GAS OUTLET VARIANTS 20 16 CONNE...

Страница 5: ...re must be used a fire proof layer ceramics stone glass or metal with minimum dimensions see Fig 1 The distance is measured from the glass in the fireplace insert Always close the door even when firep...

Страница 6: ...low those rules 05 1 6 FIRE IN THE CHIMNEY When burning wood sparks from the fireplace may get into the chimney and ignite the built up layer of soot Therefore the fireplace insert smoke flue and the...

Страница 7: ...air supply into the freplace insert must not be modifed 2 FUEL It is forbidden to interfere with the construction of freplace insert If any unauthorized technical modifcations are made the manufacture...

Страница 8: ...insert and rapidly shortens its service life In the case of repeated burning of wet wood the insert or parts of the insert can be damaged This will also block the chimney and increase the risk of fire...

Страница 9: ...closing 1 if you want the door to automatically close inform your freplace builder before starting construction 3 1 DESCRIPTION OF CONTROL ELEMENTS 1 handles for opening the door for cleaning 2 handl...

Страница 10: ...F AIR SUPPLY 4 OPERATION OF FIREPLACE INSERTS 1 Set the handle for regulation of the air supply for burning to the maximum This ensure a sufficient supply of air for ignition 09 4 Close the door and o...

Страница 11: ...of the collected gases with the oxygen 10 Note In all the models the opening of air supply is when it is marked number 1 the closing of air supply is when it is marked number 0 4 2 OPERATION IN THE TR...

Страница 12: ...iftdoor first open all the handles along the perimeter Fig 10a Then open the door into the cleaning position 11 FIG 10A FIG 10B Only clean the glass with a wet paper cloth If this is insufficient appl...

Страница 13: ...combustion air is not opened the line for the external air supply is blocked contact your fireplace technician the draught of the chimney is insufficient in the transient period Smoke escapes into the...

Страница 14: ...warranty does not apply to damage originated during transport due to incorrect storage in a wet environment The warranty does not apply to common wearing of the freplace insert The warranty does not a...

Страница 15: ...the warranty period For the replaceable parts the warranty period stated by law is valid To make a warranty claim contact your freplace technician and submit warranty certifcate description and photo...

Страница 16: ...KW 0 031 3 4 kg h 87 CRYSTAL 110 MAX 18 KW 0 028 3 4 kg h 88 QUATTRO 80 MAX 13 KW 0 036 2 3 kg h 89 QUATTRO 90 MAX 14 KW 0 033 2 3 kg h 87 QUATTRO 100 MAX 17 KW 0 045 3 4 kg h 85 FLAT Premium 60x50 13...

Страница 17: ...supply must be ensured in the room Burning 1 kg of the wood requires approximately 12 m3 of air There must not be any electric cables running through the wall or ceiling where the fireplace insert wil...

Страница 18: ...ng the transport handles which can be inserted into the on the body of the fireplace insert Fig 1 Before transporting make sure that both the ejection mechanism of the doors applicable to fireplace in...

Страница 19: ...foundation plate not on an unstable or movable surface 12 POSITIONING THE FIREPLACE INSERT The distance of the fireplace insert from the floor can be regulated by turning the legs Use the adjustable l...

Страница 20: ...of the door If there are any defects inform your supplier and stop the installation work After positioning the fireplace insert remove the transport securings that prevent damage to the lift down doo...

Страница 21: ...ded for connection to the accumulating flue system or for direct connection to the chimney 20 Hot air system for distributing in home Pipe for smoke connection in some models the diameter is fi 200mm...

Страница 22: ...tandards The correct operation of the chimney according to dIn En 13384 must be signed by legal authority When making the chimney calculations you must include the parameters of the freplace insert Wh...

Страница 23: ...moment that you have take out the cover part in the front side of the fireplace which is marked the logo A caminetti FIG 3 chapter 13 in the same time you have to take out the condraweight covering wh...

Страница 24: ...FLAT LIFTDOOR MODELS CORNER LIFTDOOR MODELS 24 NOTE THE DOOR OPENING IS THE SAME FOR ALL CRYSTAL MODELS CRYSTAL MODELS...

Страница 25: ...ning fire safety options for using materials and the size of the ventilation grids The construction must enable access for cleaning the consumer appliance chimney flue and chimney Figures 17a and 17b...

Страница 26: ...ea must be clean and resistant to the abrasion low of convection air from the hot air jacket All hot convectional piping must consist of form stable non flammable materials When installing a hot air j...

Страница 27: ...place insert and the surroundings as well as the bearing frame and the surroundings sealing tape or insulating paper must be inserted to covers the difference in the heat expansion of the material ent...

Страница 28: ...of 40 cm Area outside the radiation There must be a minimum gap of 5 cm between the wall of the surroundings and items from flammable materials The semi area to the surroundings must be open to preven...

Страница 29: ...aim at adding significant value to our partners customers and to the environment By implementing our unique systems benefits such as energy savings enhanced performance improved working and living en...

Страница 30: ...A caminetti factory National road km2 Korce Erseke KORCE ALBANIA info acaminetti factory com www acaminetti factory com A caminettti GmbH AM Industriegleis 6a Ergolding Germany...

Отзывы: