background image

-  

The paint is soft during burning so do not touch it.

A.caminetti

 freplace inserts are not designed to be operated with an open door. 

The f

ireplace must always be closed 

with the exception of adding fuel so as to prevent burning wood falling out 
and combustion gases leaking into the room.

1.4.  PUTTING INTO OPERATION

-   Open doors and windows in the room so that the area is
 fully 

 

ventilated. 

The frst two batches of the fuel should correspond to the lower 

limit of the recommended  batch for the product 

1.5. 

 OPEN OPERATION

remove all attached documents and accessories from the f

i

replace. when f

i

rst 

heating up the f

i

replace insert, the high temperature resistant paint will dry and

 harden. this drying and hardening is accompanied by a  smell. the fumes are 
not toxic, but are unpleasant. follow those rules:

05

1.6.  FIRE IN THE CHIMNEY

When burning wood, sparks from the fireplace may get into  the chimney and 
ignite the built up layer of soot. Therefore, the fireplace insert, smoke flue and the 
chimney must be regularly cleaned. If starting the heating after a long break in 
operation, then first check that the system is not blocked anywhere.

 A fire in the chimney is indicated by flames coming from the mouth of the chimney with 
 sparking and smoke and with a smell from the fireplace. In this case:

  Call the fire brigade!

   -  Close the air supply of the fireplace insert.
   -  Remove all flammable items from nearby the chimney

 Before the arrival of the fire brigade, do not try to extinguish the fire in the chimney         
 with water. In the case of a chimney fire, the temperature can reach up to 1,300 °C.                 

 In  this case, the water will immediately turn into a huge quantity of steam and destroy      
 the chimney.

-  After the fire is gone, contact a chimney sweep who can assess the condition of the 
 chimney.

Содержание Crystal 3D 50/60

Страница 1: ...Manual of use installation operation www acaminetti factory com...

Страница 2: ...ck metall Schott ROBAX Culimeta Skamol Insert coat made of quality steel in accordance with EN 13229 Insert components manufactured using modern cnc machines 2D Laser and press brakes Insert welded wi...

Страница 3: ...pes of wood 06 2 4 Storage of wood fuel 07 2 5 Recommended dose of fuel 3 DESCRIPTION OF CONTROL ELEMENTS 3 1 Description of control elements 08 3 2 Options for closing the door 4 OPERATION OF FREPLAC...

Страница 4: ...TS 15 10 CHECKING THE PRODUCT 16 11 CORRECT POSITIONING OF THE FIREPLACE 12 TRANSPORT 17 13 POSITIONING THE FIREPLACE INSERT 18 14 REMOVING THE TRANSPORT SECURING 19 15 GAS OUTLET VARIANTS 20 16 CONNE...

Страница 5: ...re must be used a fire proof layer ceramics stone glass or metal with minimum dimensions see Fig 1 The distance is measured from the glass in the fireplace insert Always close the door even when firep...

Страница 6: ...low those rules 05 1 6 FIRE IN THE CHIMNEY When burning wood sparks from the fireplace may get into the chimney and ignite the built up layer of soot Therefore the fireplace insert smoke flue and the...

Страница 7: ...air supply into the freplace insert must not be modifed 2 FUEL It is forbidden to interfere with the construction of freplace insert If any unauthorized technical modifcations are made the manufacture...

Страница 8: ...insert and rapidly shortens its service life In the case of repeated burning of wet wood the insert or parts of the insert can be damaged This will also block the chimney and increase the risk of fire...

Страница 9: ...closing 1 if you want the door to automatically close inform your freplace builder before starting construction 3 1 DESCRIPTION OF CONTROL ELEMENTS 1 handles for opening the door for cleaning 2 handl...

Страница 10: ...F AIR SUPPLY 4 OPERATION OF FIREPLACE INSERTS 1 Set the handle for regulation of the air supply for burning to the maximum This ensure a sufficient supply of air for ignition 09 4 Close the door and o...

Страница 11: ...of the collected gases with the oxygen 10 Note In all the models the opening of air supply is when it is marked number 1 the closing of air supply is when it is marked number 0 4 2 OPERATION IN THE TR...

Страница 12: ...iftdoor first open all the handles along the perimeter Fig 10a Then open the door into the cleaning position 11 FIG 10A FIG 10B Only clean the glass with a wet paper cloth If this is insufficient appl...

Страница 13: ...combustion air is not opened the line for the external air supply is blocked contact your fireplace technician the draught of the chimney is insufficient in the transient period Smoke escapes into the...

Страница 14: ...warranty does not apply to damage originated during transport due to incorrect storage in a wet environment The warranty does not apply to common wearing of the freplace insert The warranty does not a...

Страница 15: ...the warranty period For the replaceable parts the warranty period stated by law is valid To make a warranty claim contact your freplace technician and submit warranty certifcate description and photo...

Страница 16: ...KW 0 031 3 4 kg h 87 CRYSTAL 110 MAX 18 KW 0 028 3 4 kg h 88 QUATTRO 80 MAX 13 KW 0 036 2 3 kg h 89 QUATTRO 90 MAX 14 KW 0 033 2 3 kg h 87 QUATTRO 100 MAX 17 KW 0 045 3 4 kg h 85 FLAT Premium 60x50 13...

Страница 17: ...supply must be ensured in the room Burning 1 kg of the wood requires approximately 12 m3 of air There must not be any electric cables running through the wall or ceiling where the fireplace insert wil...

Страница 18: ...ng the transport handles which can be inserted into the on the body of the fireplace insert Fig 1 Before transporting make sure that both the ejection mechanism of the doors applicable to fireplace in...

Страница 19: ...foundation plate not on an unstable or movable surface 12 POSITIONING THE FIREPLACE INSERT The distance of the fireplace insert from the floor can be regulated by turning the legs Use the adjustable l...

Страница 20: ...of the door If there are any defects inform your supplier and stop the installation work After positioning the fireplace insert remove the transport securings that prevent damage to the lift down doo...

Страница 21: ...ded for connection to the accumulating flue system or for direct connection to the chimney 20 Hot air system for distributing in home Pipe for smoke connection in some models the diameter is fi 200mm...

Страница 22: ...tandards The correct operation of the chimney according to dIn En 13384 must be signed by legal authority When making the chimney calculations you must include the parameters of the freplace insert Wh...

Страница 23: ...moment that you have take out the cover part in the front side of the fireplace which is marked the logo A caminetti FIG 3 chapter 13 in the same time you have to take out the condraweight covering wh...

Страница 24: ...FLAT LIFTDOOR MODELS CORNER LIFTDOOR MODELS 24 NOTE THE DOOR OPENING IS THE SAME FOR ALL CRYSTAL MODELS CRYSTAL MODELS...

Страница 25: ...ning fire safety options for using materials and the size of the ventilation grids The construction must enable access for cleaning the consumer appliance chimney flue and chimney Figures 17a and 17b...

Страница 26: ...ea must be clean and resistant to the abrasion low of convection air from the hot air jacket All hot convectional piping must consist of form stable non flammable materials When installing a hot air j...

Страница 27: ...place insert and the surroundings as well as the bearing frame and the surroundings sealing tape or insulating paper must be inserted to covers the difference in the heat expansion of the material ent...

Страница 28: ...of 40 cm Area outside the radiation There must be a minimum gap of 5 cm between the wall of the surroundings and items from flammable materials The semi area to the surroundings must be open to preven...

Страница 29: ...aim at adding significant value to our partners customers and to the environment By implementing our unique systems benefits such as energy savings enhanced performance improved working and living en...

Страница 30: ...A caminetti factory National road km2 Korce Erseke KORCE ALBANIA info acaminetti factory com www acaminetti factory com A caminettti GmbH AM Industriegleis 6a Ergolding Germany...

Отзывы: