Operating and Assembly Instructions – A.B.S. Flexilo MODUL for wood pellets
Assembly
Subject to technical change
Issue 09/2016
Page 28 of 36
©A.B.S. Silo- und Förderanlagen GmbH
Suction probe Hargassner
Now bolt the suction probe to the
ground plate by means of the
intended hole (see picture).
For this use two M6x10 bolts and
two spring washers.
Then align the draft element
and bolt it to the module.
For this use the M8x16 bolts,
the washers and the stop nuts.
Suction probe Hapero
Now bolt the suction probe to the
ground plate by means of the
intended hole (see picture).
For this use two M8x16 bolts and
two spring washers.
Please note:
Take the 45 mm hose and put it
over the upper connection of
the suction probe and fasten it
using the hose clamp. Then align the draft element and bolt it to the module. Once this has
been carried out, attach the 50 mm hose to the lower
connection of the suction probe.
Important:
Hose clamp (upper) on the 45 mm hose inside
Hose clamp (lower) on the 50 mm hose outside