![A & T International 1 Скачать руководство пользователя страница 9](http://html2.mh-extra.com/html/a-and-t-international/1/1_service-manual_3066834009.webp)
9
Refer to Common section of this manual for detailed instructions on:
Controls/Components, Electrical Wiring, Start-Up, and more.
CCP PHYSICAL DIMENSIONS AND PIPING SPECIFICATIONS
Model#
Width
“A”
Width
“B”
Width
“C”
Width
“D”
Width
“E”
Drain
Hose
Ship-
ping Wt.
CW Line Size
(Supply & Re-
turn)
12
42”
16½”
10¾”
41”
5½”
1/2” I.D.
115
1/2 ” I.D.
24
49”
19”
10¾”
48”
5½”
5/8” I.D
135
5/8” I.D.
30
49”
19”
10¾”
48”
5½”
5/8” I.D.
135
3/4” I.D.
48
59”
16
1
/
8
”
12¾”
58”
7½”
5/8” I.D.
160
3/4” I.D.
CCP OBSERVED
SOUND LEVELS
Model#
Dba
12
46.3
24
50.8
30
56.0
48
64.2
CCP DISCHARGE AIR SPEED AND
THROW
Model# CFM
Coil
FPM Throw/
Ft.
12
350
Dry
290
12.4
18
650
Dry
430
18.6
30
800
Dry
533
18.6
48
1200
Dry
500
19.0
CCP HYDRONIC HEAT SPECIFICATIONS
(Single-stage Heating Only)
Model#
EWT
°F
GPM
Btuh
PD Ft.
H
2
O
12
140
2
14,500
3.4
180
2
22,900
3.4
24
140
4
27,200
5.2
180
4
43,200
5.2
30
140
4
29,800
5.2
180
4
47,300
5.2
48
140
4
40,300
6.1
180
4
64,100
6.1
CCP WITH ELECTRIC HEAT OPTIONS
Model#
Voltage
KW
Htr
Amps
Total
Amps
Min.
Cir.
Amps
Max.
Fuse
12
208/230
3
13.1
13.7
17.1
20
24
208/230
5
21.7
22.8
28.6
30
30
208/230
5
21.7
22.8
28.6
30
48
208/230
7
30.4
32.6
40.8
45
CCP ELECTRICAL SPECIFICATIONS
Model# Voltage
Hertz
Fan
FLA
Min.
Ampacity
*(1)
Max.
Fuse
*(1)
12
115
60
1.4
1.8
15
12
208/230
60
0.6
0.8
15
24
208/230
60
1.1
1.4
15
30
208/230
60
1.1
1.4
15
48
208/230
60
1.1/1.1
2.5
15
*(1) If electric heaters are installed, use Min Amp and Max Fuse from
Heater Options Chart.
CCP DIMENSIONS AND SPECIFICATIONS CONTINUED
Содержание 1
Страница 22: ...22 NOTES...
Страница 23: ...23 NOTES...
Страница 24: ...24 2201 Dwyer Avenue Utica NY 13501 1 800 228 9364 fax 1 800 232 9364...