background image

 

TECHNICAL MANUAL 

620020E05 

 

 

 

Due to the continuous products improvement, the indications of the present manual can be modified without previous warning and in any case 

are a contract commitment. The present information publishing does not represent resignation of intellectual property or patent. 

Copyright 

2009-2010 S.A. Sistel -E 08211 BARCELONA

 

 

Pag.  21

  

 

SW1 Address 

(Binary code) 

Phi6 

Address 

S

k

ee

ter 

S6

 

G

em

in

10

 

G

em

in

12

 

G

em

in

12X

 

G

em

in

25

 

G

em

in

50

 

M

S

B

 

 

L

S

B

 

 00 0001 

A1 

A1 

A1 

1 UP 

 00 0010 

A2 

A2 

A2 

2 UP 

 00 0011 

B1 

A3 

A3 

3 UP 

 00 0100 

B2 

A4 

A4 

4 UP 

 00 0101 

C1 

B1 

B1 

5 UP 

 00 0110 

C2 

B2 

B2 

6 UP 

 00 0111 

 

B3 

B3 

7 UP 

 00 1000 

 

B4 

B4 

8 UP 

 00 1001 

 

C1 

C1 

9 UP 

 00 1010 

10 

 

10 

C2 

C2 

10 

10 UP 

 00 1011 

11 

 

 

C3 

C3 

11 

11 UP 

 00 1100 

12 

 

 

C4 

C4 

12 

12 UP 

 00 1101 

13 

 

 

 

A5 

13 

13 UP 

 00 1110 

14 

 

 

 

A6 

14 

14 UP 

 00 1111 

15 

 

 

 

B5 

15 

15 UP 

 01 0000 

16 

 

 

 

B6 

16 

16 UP 

 01 0001 

17 

 

 

 

C5 

17 

17 UP 

 01 0010 

18 

 

 

 

C6 

18 

18 UP 

 01 0011 

19 

 

 

 

 

19 

19 UP 

 01 0100 

20 

 

 

 

 

20 

20 UP 

 01 0101 

21 

 

 

 

 

21 

21 UP 

 01 0110 

22 

 

 

 

 

22 

22 UP 

 01 0111 

23 

 

 

 

 

23 

23 UP 

 01 1000 

24 

 

 

 

 

24 

24 UP 

 01 1001 

25 

 

 

 

 

25 

25 UP 

 01 1010 

26 

 

 

 

 

 

1 DOWN 

 01 1011 

27 

 

 

 

 

 

2 DOWN 

 01 1100 

28 

 

 

 

 

 

3 DOWN 

 01 1101 

29 

 

 

 

 

 

4 DOWN 

 01 1110 

30 

 

 

 

 

 

5 DOWN 

 01 1111 

31 

 

 

 

 

 

6 DOWN 

 10 0000 

32 

 

 

 

 

 

7 DOWN 

 10 0001 

33 

 

 

 

 

 

8 DOWN 

 10 0010 

34 

 

 

 

 

 

9 DOWN 

 10 0011 

35 

 

 

 

 

 

10 DOWN 

 10 0100 

36 

 

 

 

 

 

11 DOWN 

 10 0101 

37 

 

 

 

 

 

12 DOWN 

 10 0110 

38 

 

 

 

 

 

13 DOWN 

 10 0111 

39 

 

 

 

 

 

14 DOWN 

 10 1000 

40 

 

 

 

 

 

15 DOWN 

 10 1001 

41 

 

 

 

 

 

16 DOWN 

 10 1010 

42 

 

 

 

 

 

17 DOWN 

 10 1011 

43 

 

 

 

 

 

18 DOWN 

 10 1100 

44 

 

 

 

 

 

19 DOWN 

 10 1101 

45 

 

 

 

 

 

20 DOWN 

 10 1110 

46 

 

 

 

 

 

21 DOWN 

 10 1111 

47 

 

 

 

 

 

22 DOWN 

 11 0000 

48 

 

 

 

 

 

23 DOWN 

 11 0001 

49 

 

 

 

 

 

24 DOWN 

 11 0010 

50 

 

 

 

 

 

25 DOWN 

Содержание 620020E05

Страница 1: ...Two pole 4x8 Switching Matrix YAV904X8 620020E05 Created 13 02 07 Updated 01 12 15 ...

Страница 2: ...A Sistel E 08211 BARCELONA Pag 2 This manual is related to the following product Product P N YAV904X8 Hardware version 02 Software version 01 Issued date 29 06 2010 Document History Version Issued date Reason E1 02 2007 Preliminar version E2 03 2010 Revision to add new PHI6 panels E3 05 2010 C language example added E4 06 2010 Change spec Max current 1A E05 5 03 2012 Included board test procedures...

Страница 3: ...3 4 Device electrical Characteristics 7 3 5 Block diagram 8 3 6 Connectors Jumpers 8 3 6 1 X1 Connector Device Power CAN 8 3 6 2 Jumpers 8 3 6 3 X2 Connector Relays 9 3 6 4 LEDs 9 3 7 YAV904X8 Dimensions 10 4 Low level CAN commands 11 4 1 Example Managing a YAV board using C language 11 5 PHI6 Explorer panel 14 6 Install Uninstall YAV modules into from a VPC Receiver 16 6 1 Receiver connector 16 6...

Страница 4: ... damaging this product products connected to it or people Only qualified and entitled 1 personnel are authorized to carry out operations of installation and routine on the devices described in this manual The company installing it would bear responsibility for any security or operating failure when such failure is due to the parameters incorrect programming The product described in this manual can...

Страница 5: ...ortant current peaks Use suitable packing material for transportation An electronic module with a lot of fragile components should be transported with a good protection packaging A collision can cause damages that could appear long time after the start up Do not install this product near heat sources strong vibrations or high humidity that exceeds the technical specifications Check that the produc...

Страница 6: ...cells The board is organized in 4 groups of 8 bipolar relays with double contact acces to each branch therefore we have the possibility to set up different multiplexer configurations depending on the connections we make inside the test fixture Set up Connections inside the fixture 1x 32 relays multiplexer Join pin 30 to pin 36 Join pin 31 to pin 37 Join pin 63 to pin 67 Join pin 64 to pin 68 Join ...

Страница 7: ...evice electrical Characteristics Parameter At Te 5 65ºC unless otherwise specified Symbol Values Unit Min Typ Max Operating Parameters Operating voltage Vbb 18 30 VDC Operating current At 24VDC IGND 40 390 mA Thermal Ratings Ambient operating temperature TA 5 65 ºC Power Dissipation TA 25 ºC PD 1 10 W Module Switching specifications Rated current Cos ø 1 60VAC IN 1 A Maximum switching voltage DC A...

Страница 8: ...me TOFF 3 ms 3 5 Block diagram 3 6 Connectors Jumpers 3 6 1 X1 Connector Device Power CAN Pin Description 1 GND 2 24V 3 CAN Low 4 CAN High 3 6 2 Jumpers Jumper Description SW1 Address CAN bus speed and the device address in the network can be set SW2 UPLOAD FACTORY USE Must be OPEN when normal operation With the jumper set we can enable the YAV board for firmware downloading through serial port SW...

Страница 9: ...w B Bit P0H 1 75 Row D Bit P1H 1 12 Row A Bit P0L 2 44 76 Row C Bit P1L 2 13 Row A Bit P0L 2 45 Row B Bit P0H 2 77 Row C Bit P1L 2 14 Row D Bit P1H 2 46 Row B Bit P0H 2 78 Row D Bit P1H 2 15 Row A Bit P0L 3 47 79 Row C Bit P1L 3 16 Row A Bit P0L 3 48 Row B Bit P0H 3 80 Row C Bit P1L 3 17 Row D Bit P1H 3 49 Row B Bit P0H 3 81 Row D Bit P1H 3 18 Row A Bit P0L 4 50 82 Row C Bit P1L 4 19 Row A Bit P0L...

Страница 10: ... modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 10 3 7 YAV904X8 Dimensions YAV boards for factors are showed below YAV904X8 is Form A ...

Страница 11: ...s 2 Relays 3 0x05 Time 10ms Set OUT All Relays Rx 0x155102xx 7 0x02 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x06 ASK ALL Relays Rx 0x155102xx 3 0x02 0x04 Autosend All Relays Status Tx 0x155202xx 6 0x02 0x04 Relays 0 Relays 1 Relays 2 Relays 3 Action Dir Ident Length Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Read I2C Data Word 24LC256 Rx 0x155102xx 5 0x02 0xFA 0xF1 ADD LOW ADD HIGH W...

Страница 12: ...UD_RATE AttrValueList 0 Baudrate AttrIdList 1 NC_ATTR_START_ON_OPEN AttrValueList 1 NC_TRUE AttrIdList 2 NC_ATTR_READ_Q_LEN AttrValueList 2 0 AttrIdList 3 NC_ATTR_WRITE_Q_LEN AttrValueList 3 1 AttrIdList 4 NC_ATTR_CAN_COMP_STD AttrValueList 4 0 AttrIdList 5 NC_ATTR_CAN_MASK_STD AttrValueList 5 NC_CAN_MASK_STD_DONTCARE AttrIdList 6 NC_ATTR_CAN_COMP_XTD AttrValueList 6 0 AttrIdList 7 NC_ATTR_CAN_MAS...

Страница 13: ...t id length Status ncWrite TxHandle sizeof Transmit Transmit if Status 0 PrintStat Status ncWrite Sleep 1000 Transmit Data 0 0x02 YAV command prefix Transmit Data 1 0x01 YAV command prefix Transmit Data 2 0x00 relay number Transmit Data 3 0x00 YAV set relay OFF command Transmit DataLength 4 Set CAN frame lenght Transmit IsRemote 0 This is not a remote frame Transmit ArbitrationId 0x15510200 assume...

Страница 14: ...y powerful tool for table top debugging of test systems or system maintenance on site The interface is very user friendly Activating a relays By clicking a relays in the panel the relays will close and its status in the panel will change See image with K1 in closed status Reset Reset button will put all relays in Open status Config tags We can give a the name desired to each relays in the board wi...

Страница 15: ...publishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 15 The name of K1 and K2 has also been changed because in his design the user will connect pins 3 and 4 to a load that is shared by different UUTs When pushing save tags green button changes will be set and the background will be grey again Exit Click this button to exi...

Страница 16: ...g label with its serial number The guarantee period is two years from invoice date 6 Install Uninstall YAV modules into from a VPC Receiver 6 1 Receiver connector 6 1 1 YAVs with 96 pin connector YAV modules are using high reliable professional receiver connectors from VPC Virginia Panel Corporation It is crucial for all modules to be installed properly in the Receiver Following pictures are showi...

Страница 17: ...l property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 17 For removing the modules unscrew and hold the module with two hands from both sides and pull straight out 6 2 Connections 6 2 1 Connecting cables into YAV module terminals Following table is showing the distance D at which user has to cut the isolation to connect a cable into the aerial clamp terminal that connects into X...

Страница 18: ... the YAV module a CAN interface will be needed Although other CAN Interfaces can be used under the responsibility of the user 6TL recom mends using any CAN bus High Speed Interface from National Instruments either USB PCI or PXI 7 2 CAN bus wiring We need to supply CAN H CAN L 24Vdc and GND to X1 connector of the YAV mod ule X1 connector of YAV module Pin Function 1 0V 2 24Vdc 3 CAN_Low 4 CAN_High...

Страница 19: ...configurable easy to expand and maintain Each modules can work independently form the tester so you can just plug each of them directly into the ITA frame of a fixture to start debugging the software without the need of using the test platform While the tester is being used to test PCBAs you have the advantage to debug or build any new configuration in a few minutes Can bus control has a big advan...

Страница 20: ...ntained in the module firmware and cannot be changed There is a different identification for each YAV module type Therefore modules of different module identification can have the same hardware address Since there are 6 bits there are up to 64 possible addresses from 0 to 63 ON 1 2 3 4 5 6 7 8 ON 1 OFF 0 LSB MSB Board Address 8 2 YAV modules standard addressing Virginia Panel Receivers Although th...

Страница 21: ...B4 B4 8 8 UP 00 1001 9 9 C1 C1 9 9 UP 00 1010 10 10 C2 C2 10 10 UP 00 1011 11 C3 C3 11 11 UP 00 1100 12 C4 C4 12 12 UP 00 1101 13 A5 13 13 UP 00 1110 14 A6 14 14 UP 00 1111 15 B5 15 15 UP 01 0000 16 B6 16 16 UP 01 0001 17 C5 17 17 UP 01 0010 18 C6 18 18 UP 01 0011 19 19 19 UP 01 0100 20 20 20 UP 01 0101 21 21 21 UP 01 0110 22 22 22 UP 01 0111 23 23 23 UP 01 1000 24 24 24 UP 01 1001 25 25 25 UP 01 ...

Страница 22: ...YAV 90304 6TL_Smema_Bridge YAV90304 48 YAV90304 YAV 90304 6TL_Hipot_Switch1 YAV90304 47 YAV90304 YAV 90304 6TL_Hipot_Switch2 H710061 0 00 0000 8710061E02 H7100 61 6TL_Conveyor_Belt X H710061 H710061 1 00 0001 8710061E02 H7100 61 6TL_Conveyor_Wide X H710061 H710061 2 00 0010 8710061E02 H7100 61 6TL_Feed_Belt X H710061 H710061 3 00 0011 8710061E02 H7100 61 6TL_Feed_Wide X H710061 H710061 4 00 0100 8...

Страница 23: ...s refers to the default and standard 6TL name given by Phi6 to each module depending on his function in the 6TL platform These aliases could be changed through Phi6 Explorer edit Tags Seventh column Platform is informing about what platform uses what modules A cross X is indicating that the module is always installed as standard delivery A cross with bar X is indicating that that module is a poten...

Страница 24: ...sponsability that the product YAV904X8 Two pole 4x8 switching matrix to which this declaration relates meets the provisions of the EU Directives listed be low Electro Magnetic Compatibility EMC directive 89 336 ECC referreing to Low voltaje directive 73 23 EEC and therefore the CE mark showed below is applied For accessories or other elements that can be connected to this product see their corresp...

Страница 25: ...l can be modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 25 10 Test Run the Phi6 software SW 6200 20 12 and and check results ...

Отзывы: