Page 35
F
IGURE
14-1
T
HE
DSI'
S FRONT PANEL DISPLAY INDICATES THAT ITS OUTPUTS ARE DISABLED
These options are provided for DSI units which also provide the “-M“ Extra Resources and “-S“ rear SMA
connector features.
The high level on SMA connector pair J3-J4 should be maintained at +1V. Details of the SMA connectors are
provided in section 3.3, “SMA Synchronization Connectors”. The control signal should be terminated in 50Ω (and
use 50Ω cables, etc.) to prevent spurious enable/disable transitions.
Clearly, the OE option is mutually incompatible with the OD option.
15
Unit – to – unit Time-Tag Synchronisation
Multiple EtherSpaceLink family units can be linked together to synchronize their internal clocks. This allows
synchronised outputs across multiple boxes and time tags to be the same across multiple units. The hardware
option “S” is required to provide the necessary SMA connectors on each unit that will be synchronised - e.g. DSI-
RG408-MS.
Units are synchronised with a daisy-chain cable between them - using rear-panel SMA connectors J7 and J8.
These connectors are grouped in pairs (J1-J2, J3-J4, J5-J6 and J7-J8) with both connectors in a pair connected
together (loop-through). In the following illustrations, connectors J7 and J8 are interchangeable.
Units to be synchronised are connected together by SMA-SMA cables, and 50Ω terminators must be added at
each end of the chain. The two connectors in a pair are simply wired to each other and may be used as a loop-
through connection, or a resistor may be inserted into one of the connectors so that the other forms a
terminated connection.