Page 15
These connectors are used as four pairs, J1-J2, J3-J4, J5-J6 and J7-J8. Connector pairs J1-J2, J3-J6 or J7-J8 may not
be present on all platforms. Refer to the functions and options installed for details of their usage.
The outer conductor of each SMA connector is ground / shield, and the inner conductor carries the signal. The
two SMA connectors in a pair are internally wired to each other and may be used as a loop-through connection
for a 50Ω-terminated line. Alternatively, a 50Ω resistive terminator may be inserted into one of the connectors in
each pair so that the other forms a terminated connection.
F
IGURE
3-2
SMA
CONNECTOR LAYOUT
Connector pair J7-J8 is used on the DSI for time synchronisation; see section 15, “Unit-to-Unit Time-Tag
synchronisation”, for details.
3.4
Discovering a Unit’s Serial Number and Installed Product Options
A unit’s serial number may be read off its front panel display at boot time. Alternatively, click the toggle switch
upwards or downwards once to view the serial number of a running unit.
3.4.1
The Unit Serial Number and its relation to the Ethernet MAC address
4Links EtherSpaceLink unit serial numbers are of the form Annn (e.g. A202).
The least-significant bits of the Ethernet Media Access Control (MAC) address of a unit are directly related to its
serial number:
Serial numbers
MAC address
A1 to A4095
00-50-C2-21-20-01 to 00-50-C2-21-2F-FF
3.4.2
Installed Product Options
When viewing the serial number of a running unit, as above, the installed Product Options are listed as two-
character acronyms within square brackets.
For the illustration in figure 6.1, the options are CO, EI, EW, ER, TT and SO. See section
xx
, “DSI Options”, for
further information on the available DSI options.
3.5. The RG408 Hardware Platform
The RG408 hardware platform is supplied with eight SpaceWire ports and with front or rear mounted SpaceWire
connectors (RG408 or RG408-R, respectively).
The hardware is optionally available with SMA connectors for external synchronization (on the RG408-S). These