Unit Object Commands
www.3ware.com
59
/c
x
stop mediascan
This command applies only to 7000/8000 controllers.
This commands stops a media scan operation on the specified controller
/cx
.
(Media scans are started using
/cx start mediascan
.)
Unit Object Commands
Unit Object commands provide information and perform actions related to a
specific unit, such as
/c0/u1
(unit 1 on controller 0). For example, you use
logical disk object commands for such tasks as seeing the rebuild, verify, or
initialize status of a unit, starting, stopping, and resuming rebuilds and
verifies, and setting policies for the unit.
Syntax
/c
x
/u
x
show
/c
x
/u
x
show
attribute
[
attribute ...
] where attributes are:
initializestatus|cache|name(9000 series)|
qpolicy(9550SX, 9590SE, 9650SE)|rebuildstatus|
serial(9000 series)|status|verifystatus|
storsave(9550SX, 9590SE, 9650SE)|volumes(9000 series)|
ignoreECC (9000 series)|identify (9550SX, 9590SE,
9650SE)
/c
x
/u
x
show all
/c
x
/u
x
start rebuild disk=<
p:-p...
> [ignoreECC]
/c
x
/u
x
start verify
/c
x
/u
x
pause rebuild (7000/8000 only)
/c
x
/u
x
resume rebuild (7000/8000 only)
/c
x
/u
x
stop verify
/c
x
/u
x
flush
/c
x
/u
x
del [noscan] [quiet]
/c
x
/u
x
set autoverify=on|off
/c
x
/u
x
set cache=on|off [quiet]
/c
x
/u
x
set identify=on|off (9550SX, 9590SE, 9650SE only)
/c
x
/u
x
set ignoreECC=on|off
/c
x
/u
x
set qpolicy=on|off (9550SX, 9590SE, 9650SE only)
/c
x
/u
x
set name=string (9000 series)
/c
x
/u
x
set storsave=protect|balance|perform [quiet](9550SX,
9590SE, 9650SE)
/c
x
/u
x
migrate type=
RaidType
[disk=
p:-p
]
[group=3|4|5|6|7|8|9|10|11|12] [stripe=
Stripe
] [noscan]
[nocache] [autoverify] (9000 series) RaidType = {raid0,
raid1, raid5, raid6(9650SE only), raid10, raid50,
single}
/c
x
/u
x
remove [noscan] [quiet]