Unit Object Commands
www.3ware.com
69
The
quiet
attribute turns off interactive mode.
/c
x
/u
x
set identify=on|off
This feature only applies to 9550SX, 9590SE, and 9650SE model controllers.
This feature requires an enclosure that uses an integrated AMCC/3ware CCU
(chassis control unit), such as the 3ware Sidecar, or a chassis from a third-
party vendor. (Check the 3ware web site for a list of chassis vendors that
support enclosure services, as they become available.) For additional
information about enclosure-related commands, see “Enclosure Object
Commands” on page 87.
This command allows you to identify a unit within an enclosure by blinking
the LEDs associated with the drive slots of the specified unit.
Example:
//localhost> /c0/u0 set identify=on
Sending Identify request for unit /c0/u0 to [on] ... Done.
/c
x
/u
x
set ignoreECC=on|off
This feature only applies to 9000 series controllers.
This command allows you to set the ignoreECC policy for a given unit.
When ignoreECC policy is set to
off,
if a rebuild process encounters bad
sectors on the source disk, the rebuild will fail. When ignoreECC is set to
on
,
such errors are ignored, and the rebuild will continue. When you use
ignoreECC, a file system check is recommended following the rebuild, to
insure data integrity.
By default, ignoreECC is
off
.
See Table 8, “Supported Model-Unit Types for ignoreECC,” on page 43
Table 10: Supported RAID Types for Caching
Model
R0
R1
R5
R6
R10
R50
Single
JBOD
Spare
7K/8K
Yes
Yes
Yes
N/A
Yes
N/A
N/A
Yes
No
9000
a
a. Models 9500S, 9550SX, and 9590SE
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
No
9650SE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No