User manual
CHAPTER 7 Function setting
7.1 DIP switch
IES7110-3GS series have 4 DIP switch. Can default factory through DIP 2
DIP switch
ON function
1
Hold
2
Factory default
3
Hold
4
Hold
7.1.1 Default factory
Put the DIP switch 2 to ON, Power ON again, the default factory finished. After default factory, must
put the DIP switch to OFF, otherwise, will default factory again when power ON next time.
:
Except DIP switch 2 need to put ON when default factory. Other DIP switches must always in OFF status, otherwise, the
device may work unusual