User manual
(
Figure 6.8.1
)
Read Community
Use a character string to name a SNMP community. This community only has Get privilege.
Read/Write Community
Use a character string to name a SNMP community. This community has Get and Set privilege.
SNMP TRAP Gateway
IP address of the receiver of the alarm information sent Agent
The device supports warm start of Trap. If existed IP address in Trap gateway, click "Apply", the Trap
receiver can get the trap information. If the trap receiver cannot get trap information, please check network
setting and connecting. Please pay attention to the privilege of Read and Write in SNMP Explorer.
6.8.2 Relay Alarm
Warning had 2 type: Power alarm, port alarm. Main function: once the devices were in unusual status,
can inform administrator in time and repair the status of device quickly, can avoid more lose
Relay warning input type: Close/Open. Once select Close, the light will be bright when have alarm. Relay will
be in open status.
Power alarm
IES7110-3GS series provided dual DC power supply (AC power supply did not have alarm), if one
power supply had problem, another will support power supply immediately, dual power supply hot back-up.
Select to enable power alarm, If power supply was in unusual status, device will send alarm signal, inform
power supply work unusual.
Port Alarm
Alarm when port disconnect. Enable port alarm, if port was in unusual status(Connect or disconnect),
device will output a signal, inform the device work unusual.