background image

26

WARRANTY

3M warrants that Versaflo™ Powered Air Purifying Respirator (PAPR) and Supplied Air Respirator (SAR) 

systems, and their component parts will be free from defective materials and workmanship at the 

time of purchase and will cover the parts listed below for the time periods indicated, provided they 

are maintained and used in accordance with the product’s 

User Instructions

 and/or recommendations. 

3M’s only obligation under this Warranty will be, at 3M’s option, to repair or replace without charge any 

defective parts of the Versaflo™ Respirator Product returned to 3M in accordance with the instructions 

below and found by 3M to have been defective at the time of purchase or during the warranty period 

as applicable. This Warranty does not apply to any parts that have been misused, altered or had repair 

attempted, or have been subjected to abuse, accidental or otherwise. The extended Warranty does not 

apply to expendable consumables, accessories, or fabric components such as but not limited to: filters/

cartridges, face seals, shrouds, hoods and head covers, and visors.  
Warranty time periods for specified parts:

-  PAPR Blower Unit, excluding consumables: 2000 hours of use or 1 year from date of purchase, 

whichever occurs sooner.

-  Batteries: 250 cycles or 1 year from date of purchase, whichever occurs sooner.

-  Battery chargers, SAR Valves, SAR Panels, excluding consumables, and Respiratory Faceshields, Hard 

Hats, and Helmets, excluding consumables, 1 year from date of purchase.

-  CO monitors, 2 years from date of purchase.

EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED 

WARRANTY OR CONDITION OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER 

WARRANTY OR CONDITION OF QUALITY, EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT.

LIMITATION OF LIABILITY

Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, 

indirect, incidental, special or consequential, arising out of sale, use or misuse of 3M™ Versaflo™ 

Products, or the user’s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE.

FOR MORE INFORMATION

In United States, contact:

Website: www.3m.com/workersafety

Technical Assistance: 1-800-243-4630

For other 3M products:

1-800-3M-HELPS or 1-651-737-6501

RENSEIGNEMENTS SUPPLÉMENTAIRES

Aux 

États

-Unis :

Internet : www.3m.com/workersafety

Assistance technique : 1 800 243-4630 

Autres produits 3M : 

1 800 364-3577 ou 1 651 737-6501

 

PARA MAYORES INFORMES 

En Estados Unidos:

Sitio Web: www.3m.com/workersafety 

Soporte técnico: 1-800-243-4630

Para otros productos 3M:

 

1-800-3M-HELPS o 1-651-737-6501

PARA MAIS INFORMAÇÕES 

Nos Estados Unidos, entre em contato com: 

Website: www.3m.com/workersafety

Assistência Técnica: 1-800-243-4630 

Para outros produtos 3M: 

1-800-3M-HELPS ou 1-651-737-6501

FOR MORE INFORMATION

In Canada, contact:

Internet: www.3M.ca/Safety

Technical Assistance: 1-800-267-4414

Customer Care Center: 1-800-364-3577

[email protected]      |      http://www.bestmaterials.com      |      1-800-474-7570

Distributed by Best Materials® LLC

Содержание Versaflo M Series

Страница 1: ...oria Serie M 400 Capacete Respirat rio da S rie M 300 M Series Headgear User Instructions for Pi ce faciale de s rie M Directives d utilisation pour Casco Serie M Instrucciones de uso para Equipamento...

Страница 2: ...445 M 446 M 447 M 448 M 449 Outer Shrouds M 400 Series 15 M 444 Inner Shrouds M 400 Series 15 M 116 and M 316 Airflow Deflectors 16 M 154 Replacement Forehead Seal M 100 and M 200 Series 16 M 354 Rep...

Страница 3: ...100 Series Headgear the M 200 Series Headgear comes with a solid headgear shell to provide lightweight head coverage from dirt debris and overspray as well as minimal head protection from contact with...

Страница 4: ...stand impact and penetration and may result in serious injury or death a Use only the cleaning processes and agents described in these User Instructions to clean the visor b Ensure visor buttons are f...

Страница 5: ...irators E Medical Evaluation F Fit Testing G Use of Respirators H Maintenance and Care of Respirators I Breathing Air Quality and Use J Identification of Cartridges Filters and Canisters K Training an...

Страница 6: ...eadgear M Series M 105 M 107 M 206 M 207 M 305 M 307 M 405 and M 407 are provided fully assembled Prior to use ensure any protective covering or film that may have been placed over the visor to protec...

Страница 7: ...pproved breathing tube to the headgear See Connecting Disconnecting Breathing Tubes section for additional information 2 With the visor lens in the up position place the headgear on your head 3 Turn t...

Страница 8: ...e jaw b M 400 Ensure visor is firmly closed completely latched in the down position You should hear an audible click when it is fully closed Tighten the adjustable cord on the inner shroud until there...

Страница 9: ...nd may result in serious injury or death a Do not use in high heat environments above the recommended maximum temperature With the respirator in operation enter the contaminated area breathing normall...

Страница 10: ...gear shell Look for visible damage including dents cracks color change chalking or fading Any M 300 M 400 Headgear subjected to impact should be removed from service and replaced even if damage is not...

Страница 11: ...n for additional information Fig 6a shows the pivot kit From the top down the part marked 3M is the post 1 the next part is the back plate 2 and the bottom part in the Fig 6a is the metal spring clip...

Страница 12: ...ce broken or worn buttons move the visor frame to the up open position Remove visor from frame as described in the previous section Remove worn or broken button s Gently use a tool if necessary e g pl...

Страница 13: ...Pad To replace comfort pad unsnap pad and remove from headband Wrap new comfort pad around the headband in the area that comes into contact with your forehead and secure by closing the three snaps Fig...

Страница 14: ...nsion M 300 M 400 Series NOTE for M 300 Series users You must first detach the faceseal from the suspension headband See M 935 M 936 M 937 Faceseals in this section for additional information To repla...

Страница 15: ...ceseal with this side facing up grasp the black gasket on the faceseal and align with the edge of the groove in the visor frame Starting with one edge press the gasket firmly into the groove in small...

Страница 16: ...et through hole in shroud Fig 14a Grasp the black shroud gasket and pull to expose the edge of the gasket where it meets the elastic Fig 14c Align the edge of the gasket with the edge of the groove in...

Страница 17: ...o the groove Grasp fabric tab with button and fold over to inside of suspension Attach forehead seal button to head suspension Fig 16b Fig 16a Fig 16b M 354 Replacement Forehead Seal M 300 Series The...

Страница 18: ...es Headgear Do not use on any other headgear including faceshields and eyewear Misuse may result in permanent eye injury and vision loss M 926 and M 928 Peel off Visor Covers Ensure the visor is clean...

Страница 19: ...so may affect performance and reduce the degree of protection provided Before use store the M 929 shaded peel off covers in original unopened packaging in a clean area that is protected from contamina...

Страница 20: ...visor gasket M 921 is re installed on M Series Headgear prior to use Fig 20 M 972 Flame Resistant Headgear Cover The headgear cover can be used to help keep dirt debris overspray etc off the headgear...

Страница 21: ...stability for smaller head sizes To install peel off backing on comfort pad and attach to ratchet back plate Ensure back plate is clean and dry prior to installation Hold pad in place with hand pressu...

Страница 22: ...gear following the same procedure Fig 22a X O Fig 22b Fig 22c Fig 22d Fig 22e The earmuffs can be placed in three positions Usage When in use the wire bands must be pushed fully inward toward your hea...

Страница 23: ...mild solution of soapy water may be used to wipe down the M Series visors headgear shells head suspensions including the webbing and all other plastic parts Rinse with clean water Washing temperature...

Страница 24: ...or fabric conditioners Thoroughly air dry before storage Inspect closely before reuse Dispose of when worn or damaged Breathing Tubes Breathing tubes may be wiped down with warm soapy water If liquid...

Страница 25: ...ad M 956 and peel off M 926 M 107 Respiratory Faceshield Assembly includes premium visor M 927 flame resistant faceseal M 937 size reducing comfort pad M 956 and peel off M 928 M 206 37299 Respiratory...

Страница 26: ...ent Visor Pivot Kit includes 2 pivots 2 springs and 2 back plates Accessories M 928 37452 Peel Off Visor Covers for M 927 Premium Visor M 926 37322 Peel Off Visor Covers for M 925 Standard Visor M 929...

Страница 27: ...d Hats and Helmets excluding consumables 1 year from date of purchase CO monitors 2 years from date of purchase EXCLUSIONS TO WARRANTY THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY...

Отзывы: