Step 3: Connect water supply to the SGLP-RO System

Step 4: Remove SW-IX-60 cartridge and install filter plug 

included with the RO system (For SW4-PLUS ONLY)

NOTE: If possible, the water supply should be tee’d off of the existing filter system. Refer 

to installation diagrams below.

For SW3-PLUS and SW260-PLUS, follow these steps. 

1)  Close the water inlet valve on the existing beverage and ice filter system.
2)  Run ¼” tubing from the filter system outlet to the SGLP-RO using the appropriate fittings 

and tubing (not included).

For SW4-PLUS, follow these steps. 

1)  Close the water inlet valve on the existing beverage and ice filter system.
2)  Run ¼” tubing from the filter system outlet to the SGLP-RO using the appropriate fittings 

and tubing (not included).

Tee Fitting 

(Not Included)

To SGLP-RO

Inlet - 3/8"

Flare Fitting

To Post Mix

Dispenser

To SGLP-RO Inlet

NOTE: This step is for the SW4-PLUS system only. If a SW3-PLUS or SW260-PLUS 

system is installed, skip to next step.

1)  Remove the SW-IX-60 cartridge by rotating cartridge to the right and pulling down on it.
2)  Dispose of cartridge in accordance with federal, state, and local regulations
3)  Insert filter plug that was included with the SGLP-RO Reverse Osmosis System by 

inserting plug in filter head and turning to the right until plug hits stop. You should hear a 

click when the plug is fully inserted.

5

Содержание SGLP-RO

Страница 1: ...Model SGLP RO Reverse Osmosis System Quick Installation Guide Note Installer please leave with owner operator 3M Water Filtration Products...

Страница 2: ...ollow all safety information contained in these instructions prior to installation and use of the 3M Water Filtration Products SGLP RO Reverse Osmosis System Retain these instructions for future refer...

Страница 3: ...elief valve Where a booster pump is installed on a water system you MUST install an appropriate pressure regulating valve and regulate water pressure to 80psi Contact a plumbing professional if you ar...

Страница 4: ...stem for inlet and outlet tubing connections 3 Allow 3 clearance below the system for cartridge replacement 4 If desired a mounting bracket template is included in the installation manual NOTE Mountin...

Страница 5: ...et valve on the existing beverage and ice filter system 2 Run tubing from the filter system outlet to the SGLP RO using the appropriate fittings and tubing not included Tee Fitting Not Included To SGL...

Страница 6: ...above This fitting should be used with flexible tubing A 3 8 stem x quick connect fitting is also included for rigid poly tubing Brine Out Port RO Outlet to Duke Oven 3 8 Blue Tubing Outlet Tee Water...

Страница 7: ...e the plug from the RO Membrane drain fitting by pushing down on collet while pulling plug out 3 Insert red reject tube into membrane drain fitting 4 Insert RO Membrane into filter head Be sure that t...

Страница 8: ...LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ARISING OUT OF A COURSE OF DEALING CUSTOM OR USAGE OF TRADE This warranty does not cover labor If th...

Отзывы: