3M™MicroTouch™ System DST2270DX Integration Guide
29
3M Touch Systems, Inc. Proprietary Information – TSD-25739
1.
Prep the display by placing a border of polyimide tape or similar tape around the
perimeter of it.
2.
Place the sensor on foam blocks and be sure that it is clean and dry.
3.
Already attached to the sensor are strips of foam VHB tape. Pull off about 2 inches
of the release liner from the end of each strip and fold at a 90 degree angle.
4.
You are now ready to attach the sensor to the display. It is recommended that at least
two people complete this step. Hold the sensor so the flex tail exits from the top, turn
the sensor over and place it on the display.
5.
Holding the sensor firmly in place, slowly pull out the remainder of the release liner.
Repeat this with all four sides.
6.
Press firmly down around the perimeter of the sensor to ensure that it is fully
attached to the display
Gently Pull Out
VHB Tape
Polyimide Tape
Fold Back Release Liner