 CAUTION

To reduce the risks associated with hot surfaces and hot exhaust gases:

•  Do not touch the membrane contactor or liquid lines during operation or cleaning and drying. 

Surfaces may be hot. 

•  Avoid close proximity to blower exhaust.

To reduce the risks associated with environmental contamination:

•  Exhaust gas should be vented in a safe manner and according to local regulations.

To reduce the risks associated with damaging the membrane contactor: 

• 

Ensure membrane contactor is properly aligned with piping, and flanges are adequately 

tightened during use and after cleaning. Always conduct system checks in accordance with 

installation instructions and facility policies prior to operation. 

• 

Ensure proper draining and flushing of membrane contactor before maintenance, service, or 

shipping of membrane contactors.

NOTICE 

•  To reduce membrane contactor or system damage:

• 

Care must be taken not to drop, hit or impact the membrane contactor.

•  If the membrane contactor is used with air sweep, then the temperature should not exceed 35°C 

(95°F). For membrane contactors used with vacuum only this statement does not apply.

• 

To avoid contamination of the process fluid, gloves are recommended when handling the 

membrane contactors.

•  All plastic port extensions should be supported to prevent bending of extensions under excessive 

piping loads.

•  3M Liqui-Cel Membrane Contactor products should be stored dry and in a sealed plastic bag 

or shrink wrap material to help prevent the introduction of contaminants into the membrane 

contactor.

•  3M Liqui-Cel Membrane Contactor products should be stored in their original box, or other 

opaque box, and should not be installed where they are exposed to direct sunlight.

•  Store 3M Liqui-Cel Membrane Contactor products dry at temperatures < 50 °C (122 °F), but 

preferably at lower temperature such as <35 °C (95 °F), to not risk reduced lifetime. 

• 

3M Liqui-Cel Membrane Contactor products should always be stored above freezing 

temperatures, and if stored at low temperature, they should be allowed to equilibrate to room 

temperature before use.

• 

Do not use thread sealant to connect fittings to membrane contactor.

• 

Use care if using a metal fitting to connect to a plastic connector on the membrane contactor.

• 

Do not allow membrane contactors containing microporous hollow fiber membranes to come 

into contact with surfactants, oil, or organic solvents, such as pure alcohols, glycol, acetone, etc., 

to reduce the risk of membrane wet out. 3M Liqui-Cel SP-Series Membrane Contactor products 

containing polyolefin membrane are not subject to this restriction.

• 

To protect the membrane contactors, prefiltration equipment should be inspected and 

maintained in accordance to 3M Liqui-Cel Membrane Contactors Inlet Water & Sweep Gas 

Operating Guidelines, in the Technical Resources section at 3M.com/Liqui-Cel.

•  Suspended solids, biological contaminants, or the precipitation of soluble or insoluble salts on 

the membrane surface may lead to membrane plugging.

• 

Filtered, de-chlorinated, and deionized water is recommended for mixing cleaning solutions. If 

a pH shift occurs in water containing sparingly soluble compounds of Ca, Mg, Fe, Al, and silica 

(SiO₂) etc. precipitation from the solution could occur, blocking or damaging the membrane. 

Ensure that your water is free of these compounds.

Содержание Liqui-Cel EXF-14 28 Series

Страница 1: ...3M Liqui Cel EXF 14x28 Series Membrane Contactor with Engineered Thermoplastic End Caps Including products used for TransMembrane ChemiSorption TMCS applications Assembly and Disassembly Instructions ...

Страница 2: ...Contents Safety Information 3 Required Materials 7 Disassembly Remove the End Caps 8 Assembly Installing the End Caps 9 Attach the End Cap to the Contactor Vessel 10 ...

Страница 3: ...er it includes a F B designation and can be used for such applications 3M Liqui Cel Membrane Contactor products may further be used in the production of water for various pharmaceutical products upstream of the final water sterilization step Product Selection Since there are many factors that can affect a product s use the customer and user remain responsible for determining whether the 3M product...

Страница 4: ...ture limits Implement workplace safety risk controls according to local applicable laws and regulations Always use appropriate personal protective equipment PPE when installing servicing operating cleaning or disposing of the membrane contactor All plumbing should be done in accordance with local regulations and code To prevent buildup of pressure inside the membrane contactor do not block or valv...

Страница 5: ...embrane Contactor products should be stored in their original box or other opaque box and should not be installed where they are exposed to direct sunlight Store 3M Liqui Cel Membrane Contactor products dry at temperatures 50 C 122 F but preferably at lower temperature such as 35 C 95 F to not risk reduced lifetime 3M Liqui Cel Membrane Contactor products should always be stored above freezing tem...

Страница 6: ...uirements that different chemicals could present User is responsible for ensuring that chemicals are only used by persons familiar with their use and hazards for example personnel who have received hazardous material training and who have the appropriate protective equipment as specified in their organization s safety program and the chemical s safety datasheet SDS User assumes all responsibility ...

Страница 7: ...Required Materials Tools 3 4 plastic wedges Rubber mallet Appropriate sockets or wrenches Adjustable impact or torque wrench Parts End Cap Replacement gasket and O rings ...

Страница 8: ...to avoid damage 5 Using a rubber mallet gently tap the wedge until there is enough space between the gasket and the end cap for a second wedge as shown in figure 2 6 Insert a second wedge between the gasket and the end cap at 90 from first one Gently tap the second wedge until there is a large enough gap for a third wedge at 90 See figure 2 7 Repeat this process for a third wedge If needed repeat ...

Страница 9: ...ints are critical to product strength Do not deviate from the positions shown in figure 5 Notes Orient the lifting ring of the second end cap 180 from the first lifting ring When adding the tie bar make sure it curves the same way as the backing ring and contactor vessel flange Nozzle orientation should be the same as the original 5 Insert bolts with large flat washers completely through the bolt ...

Страница 10: ...d press the end cap nozzle into the contactor vessel center tube as far as it will go 3 Add a large flat washer a lock washer and a nut to each bolt and tighten by hand 4 Use an impact or torque wrench set to 30 ft lbs in a star pattern to tighten the nuts This will evenly pull the end cap into the center tube Note Use a wrench on the bolt head to prevent the bolt from rotating during tightening 5...

Страница 11: ...meet all applicable safety regulations may result in injury sickness death and or harm to property Limited Warranty Limited Remedy and Disclaimer Unless a different warranty is expressly identified on the applicable 3M product literature or packaging in which case such express warranty governs 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the p...

Отзывы: