background image

3M Company 

3M Separation and Purification 

Sciences Division 

13840 South Lakes Drive

 

Charlotte, North Carolina 28273 

U.S.A.
Phone  +1 980 859 5400 

Web www.3M.com/liqui-cel

Technical Information: 

 The technical information, guidance, and other statements contained in this document or 

otherwise provided by 3M are based upon records, tests, or experience that 3M believes to be reliable, but the accuracy, 

completeness, and representative nature of such information is not guaranteed. Such information is intended for people 

with knowledge and technical skills sufficient to assess and apply their own informed judgment to the information. No 

license under any 3M or third party intellectual property rights is granted or implied with this information.

Product Selection and Use:

  Many factors beyond 3M’s control and uniquely within user’s knowledge and control can 

affect the use and performance of a 3M product in a particular application. As a result, customer is solely responsible 

for evaluating the product and determining whether it is appropriate and suitable for customer’s application, including 

conducting a workplace hazard assessment and reviewing all applicable regulations and standards (e.g., OSHA, ANSI, 

etc.). Failure to properly evaluate, select, and use a 3M product and appropriate safety products, or to meet all applicable 

safety regulations, may result in injury, sickness, death, and/or harm to property.

Limited Warranty, Limited Remedy, and Disclaimer:

  Unless a different warranty is expressly identified on the applicable 

3M product literature or packaging (in which case such express warranty governs), 3M warrants that each 3M product 

meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES 

OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR 

CONDITION OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ARISING OUT OF A COURSE 

OF DEALING, CUSTOM, OR USAGE OF TRADE. If a 3M product does not conform to this warranty, then the sole and 

exclusive remedy is, at 3M’s option, replacement of the 3M product or refund of the purchase price.

Limitation of Liability:

  Except for the limited remedy stated above, and except to the extent prohibited by law, 3M 

will not be liable for any loss or damage arising from or related to the 3M product, whether direct, indirect, special, 

incidental, or consequential (including, but not limited to, lost profits or business opportunity), regardless of the legal or 

equitable theory asserted, including, but not limited to, warranty, contract, negligence, or strict liability

3M Deutschland GmbH

3M Separation and Purification 

Sciences Division

Öhder Straße 28 

42289 Wuppertal, Germany

Phone: +49 202 6099-0

© 3M 2022. All rights reserved. 3M and Liqui-Cel 

are trademarks of 3M Company. Please recycle.

REV 10-2022

Содержание Liqui-Cel EXF-14 28 Series

Страница 1: ...3M Liqui Cel EXF 14x28 Series Membrane Contactor with Engineered Thermoplastic End Caps Including products used for TransMembrane ChemiSorption TMCS applications Assembly and Disassembly Instructions ...

Страница 2: ...Contents Safety Information 3 Required Materials 7 Disassembly Remove the End Caps 8 Assembly Installing the End Caps 9 Attach the End Cap to the Contactor Vessel 10 ...

Страница 3: ...er it includes a F B designation and can be used for such applications 3M Liqui Cel Membrane Contactor products may further be used in the production of water for various pharmaceutical products upstream of the final water sterilization step Product Selection Since there are many factors that can affect a product s use the customer and user remain responsible for determining whether the 3M product...

Страница 4: ...ture limits Implement workplace safety risk controls according to local applicable laws and regulations Always use appropriate personal protective equipment PPE when installing servicing operating cleaning or disposing of the membrane contactor All plumbing should be done in accordance with local regulations and code To prevent buildup of pressure inside the membrane contactor do not block or valv...

Страница 5: ...embrane Contactor products should be stored in their original box or other opaque box and should not be installed where they are exposed to direct sunlight Store 3M Liqui Cel Membrane Contactor products dry at temperatures 50 C 122 F but preferably at lower temperature such as 35 C 95 F to not risk reduced lifetime 3M Liqui Cel Membrane Contactor products should always be stored above freezing tem...

Страница 6: ...uirements that different chemicals could present User is responsible for ensuring that chemicals are only used by persons familiar with their use and hazards for example personnel who have received hazardous material training and who have the appropriate protective equipment as specified in their organization s safety program and the chemical s safety datasheet SDS User assumes all responsibility ...

Страница 7: ...Required Materials Tools 3 4 plastic wedges Rubber mallet Appropriate sockets or wrenches Adjustable impact or torque wrench Parts End Cap Replacement gasket and O rings ...

Страница 8: ...to avoid damage 5 Using a rubber mallet gently tap the wedge until there is enough space between the gasket and the end cap for a second wedge as shown in figure 2 6 Insert a second wedge between the gasket and the end cap at 90 from first one Gently tap the second wedge until there is a large enough gap for a third wedge at 90 See figure 2 7 Repeat this process for a third wedge If needed repeat ...

Страница 9: ...ints are critical to product strength Do not deviate from the positions shown in figure 5 Notes Orient the lifting ring of the second end cap 180 from the first lifting ring When adding the tie bar make sure it curves the same way as the backing ring and contactor vessel flange Nozzle orientation should be the same as the original 5 Insert bolts with large flat washers completely through the bolt ...

Страница 10: ...d press the end cap nozzle into the contactor vessel center tube as far as it will go 3 Add a large flat washer a lock washer and a nut to each bolt and tighten by hand 4 Use an impact or torque wrench set to 30 ft lbs in a star pattern to tighten the nuts This will evenly pull the end cap into the center tube Note Use a wrench on the bolt head to prevent the bolt from rotating during tightening 5...

Страница 11: ...meet all applicable safety regulations may result in injury sickness death and or harm to property Limited Warranty Limited Remedy and Disclaimer Unless a different warranty is expressly identified on the applicable 3M product literature or packaging in which case such express warranty governs 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the p...

Отзывы: