![3M E-A-Rfit Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/3m/e-a-rfit/e-a-rfit_user-instructions_444016015.webp)
13
The personal attenuation rating (PAR) is displayed for both the left and right ears as well as a binaural value. The values have
the uncertainty subtracted and displayed on this tab. The binaural PAR is calculated using the lowest attenuation value per
octave band for each ear.
IMPORTANT NOTE
i
3M™ uses PAR minus the uncertainty value to calculate user protection. Calculated uncertainty includes user fitting variability,
variability in the user’s noise spectrum, and the measurement of variability itself.
Left and Right Values
The left and right values are the computed results from the fit test for each ear with the uncertainty value subtracted. See for
additional details.
Protection
The Protection tab shows the employee's protected exposure in a similar manner to the guidance in the European guidance
document EN 458 and the Canadian hearing protection standard CSA Z94.2. The protected exposure is calculated by
subtracting the binaural PAR (minus the uncertainty) from the employee's exposure.
Safety Guide
The Safety Guide indicates where the employee fit-test results are located on a risk spectrum.
Fitting Gauge
The Fitting Gauge is an estimate of where the employee PAR value compares to what can be achieved with the hearing
protector tested.