1.0  PRODUCT APPLICATION

1.1 PURPOSE:

 3M Self-Retracting Devices (SRDs) are designed for use as a connecting subsystem in a Fall Protection 

system. Once anchored, the lifeline extends and retracts automatically as the worker moves. If a fall occurs, a sensing 

mechanism activates the device and arrests the fall. For more information on system applications, refer to the “Product 

Overview“ and Table 1.

1.2   SUPERVISION:

 Use of this equipment must be supervised by a Competent Person.

1.3 STANDARDS:

 Your product conforms to the national or regional standards identified on the front cover of these 

instructions. If this product is resold outside the original country of destination, the re-seller must provide these 

instructions in the language of the country in which the product will be used.

1.4 TRAINING:

 This equipment must be installed and used by persons trained in its correct application. These instructions are to be used 

as part of an employee training program as required by national, regional, or local standards. It is the responsibility of the users and 

installers of this equipment to ensure they are familiar with these instructions, trained in the correct care and use of this equipment, 

and are aware of the operating characteristics, application limitations, and consequences of improper use of this equipment.

1.5   RESCUE PLAN: 

When using this equipment and connecting subsystems, the employer must have a written rescue plan and 

the means to implement and communicate that plan to users, authorized persons, and rescuers. A trained, on-site rescue team 

is recommended. Team members should be provided with the equipment and techniques necessary to perform a successful 

rescue. Training should be provided on a periodic basis to ensure rescuer proficiency. Rescuers should be provided with these 

instructions. There should be visual contact or means of communication with the person being rescued at all times during the 

rescue process.

2.0  SYSTEM REQUIREMENTS

2.1 ANCHORAGE:

 Anchorage requirements vary with the Fall Protection application. The mounting structure on which the 

equipment is placed must meet the Anchorage specifications defined in Table 1.

2.2 CAPACITY: 

The user capacity of a complete Fall Protection system is limited by its lowest rated maximum capacity component. 

For example, if your connecting subsystem has a capacity that is less than your harness, you must comply with the capacity 

requirements of your connecting subsystem. See the manufacturer instructions for each component of your system for capacity 

requirements.

2.3 

ENVIRONMENTAL HAZARDS:

 Use of this equipment in areas with environmental hazards may require additional 

precautions to prevent injury to the user or damage to the equipment. Hazards may include, but are not limited to: high 

heat, chemicals, corrosive environments, high voltage power lines, explosive or toxic gases, moving machinery, sharp 

edges, or overhead materials that may fall and contact the user or equipment. Contact 3M Technical Services for further 

clarification.

2.4 

LIFELINE HAZARDS:

 Ensure the lifeline is kept free from all hazards including, but not limited to: entanglement with 

users, other workers, moving machinery, other surrounding objects, or impact from overhead objects that could fall onto 

the lifeline or users.

2.5 

FALL PATH AND SRD LOCKING SPEED:

 Do not use in applications that have an obstructed fall path. A clear path is 

required to lock the SRD.  Working on slowly shifting materials (e.g. sand or grain), or within limited spaces, may not 

allow the worker to reach sufficient speed to lock the SRD.

2.6 

COMPONENT COMPATIBILITY:

 3M equipment is designed for use with 3M equipment. Use with non-3M equipment 

must be approved by a Competent Person. Substitutions made with non-approved equipment may jeopardize equipment 

compatibility and may affect the safety and reliability of your Fall Protection system. Read and follow all instructions and 

warnings for all equipment prior to use.

2.7 

CONNECTOR COMPATIBILITY:

 Connectors are compatible with connecting elements when the size and shape of either 

component does not cause the connector to inadvertently open, regardless of orientation. Connectors must comply with 

applicable standards. Connectors must be fully closed and locked during use.

3M Connectors (snap hooks and carabiners) are designed to be used only as specified in each instruction manual. Ensure 

connectors are compatible with the system components to which they are connected. Do not use equipment that is non-

compatible. Use of non-compatible components may cause the connector to unintentionally disengage (see Figure 3). If 

the connecting element to which a connector attaches is undersized or irregular in shape, a situation could occur where 

the connecting element applies a force to the gate of the connector (A). This force could then cause the gate to open (B), 

disengaging the connector from the connecting element (C).

Содержание DBI SALA NANO-LOK 3101580

Страница 1: ...3101585 1 C9 Size A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101586 1 C3 C17 Size A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101587 1 C1 C16 Size A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101588 1 C5 C9 Size A DP1 11 ft 3 35...

Страница 2: ...m 4 4 ft 1 34 m 3101527 1 C1 C17 Size A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101528 1 C1 C15 Size A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101529 1 C1 C13 Size A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101530 1 C1 C11 Size A...

Страница 3: ...terials e g sand or grain or within confined spaces or limited spaces may not allow the worker to reach sufficient speed to lock the SRD Avoid sudden or quick movements during work operation because t...

Страница 4: ...stem configuration the Bottom Connector will attach to either the designated attachment element of the user s full body harness or to the system s anchorage point Energy Absorbers F dissipate kinetic...

Страница 5: ...Connector Specifications Figure 1 Reference Model Number Description Material Gate Opening Gate Strength C1 3100064 Nano Lok Harness Connector Steel 0 88 in 22 35 mm 3 600 lbf 16 kN C2 2000159 Carabi...

Страница 6: ...Performance SRDs ANSI Models OSHA Models Capacity Range 130 lb 310 lb 59 kg 140 kg 311 lb 420 lb 141 191 kg Maximum Arresting Force 1 350 lbf 6 kN 1 350 lbf 6 kN Average Arresting Force 900 lbf 4 kN...

Страница 7: ...is less than your harness you must comply with the capacity requirements of your connecting subsystem See the manufacturer instructions for each component of your system for capacity requirements 2 3...

Страница 8: ...reater C In a false engagement where size or shape of the connector or connecting element is not compatible and without visual confirmation would seem to be fully engaged D To each other E Directly to...

Страница 9: ...is the distance the user falls measured from activation of the deceleration device until stopping Harness Stretch HS is the amount of slack extending from the user s harness when the user is suspende...

Страница 10: ...0 6 2 0 9 3 1 2 4 1 5 5 m ft 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 2 1 Fall Clearance FC 59 100 kg 130 220 lb 100 140 kg 220 310 lb 2 0 m 6 6 ft 2 1 m 6 9 ft 3 3 m 10 7 ft 3 5 m 11 3 f...

Страница 11: ...user s full body harness This format enables easier transportation of the SRD and ensures that the SRD is within reach when moving between anchorage points The methods for mounting an SRD on a harnes...

Страница 12: ...ss web interface C CARABINER INTERFACE See Figure 10 for reference These instructions apply to Carabiner 2000159 when used with specific Full Body Harness models 1 Loosen the harness webbing Pull out...

Страница 13: ...The Gate can be rotated toward the nose to allow clearance for the Swivel Eye between the Gate and Spine of the Connector 4 Position the Twin Carabiner around the Web Straps With the Gate facing up in...

Страница 14: ...to fall arrest or impact force remove it from service immediately Clearly tag it DO NOT USE See Section 5 for more information 4 3 OPERATION Before using an SRD the worker will need to secure the SRD...

Страница 15: ...information on its compatibility with SRDs SRDs may be used with a horizontal system only if both products allow for such use Required Fall Clearance values presented in these instructions are based o...

Страница 16: ...oduct has been exposed to fall arrest or impact force then the product must be destroyed 5 4 PRODUCT LIFE The functional life of the product is determined by work conditions and maintenance As long as...

Страница 17: ...efinitions please visit our website www 3m com FallProtection ifu glossary AUTHORIZED PERSON A person assigned by the employer to perform duties at a location where the person will be exposed to a fal...

Страница 18: ...18 Figure 13 RFID Tag Location Figure 14 Product Labels 2 A C A B C B...

Страница 19: ...19 Figure 14 Product Labels A B C D B D B D A C...

Страница 20: ...nce and locking buttons and pins should function correctly Web Lifeline Figure 14 3 Inspect the webbing for Cuts A Frays B broken fibers tears abrasion Heavy Soiling C mold Burns D and discoloration I...

Страница 21: ...21 Figure 14 General Inspection 1 2 3 A C B B A C A A B D C B A Figure 15 Energy Absorber Inspection D B C A C A...

Страница 22: ...C16 Tama o A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101585 1 C9 Tama o A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101586 1 C3 C17 Tama o A DP1 11 ft 3 35 m 7 4 ft 2 25 m 3101587 1 C1 C16 Tama o A DP1 11 ft 3 35 m 7...

Страница 23: ...o A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101527 1 C1 C17 Tama o A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101528 1 C1 C15 Tama o A KW1 8 ft 2 4 m 4 4 ft 1 34 m 3101529 1 C1 C13 Tama o A KW1 8 ft 2 4 m 4 4 ft 1 34 m 31...

Страница 24: ...ena o granos o dentro de espacios confinados o limitados podr a no permitir que el trabajador alcance suficiente velocidad para bloquear el SRD Evite movimientos repentinos o r pidos durante las opera...

Страница 25: ...configuraci n del sistema el conector inferior se fijar a elemento de fijaci n designado del arn s de cuerpo completo del usuario o al punto de anclaje del sistema Los absorbedores de energ a F disipa...

Страница 26: ...aluminio y nylon Especificaciones del conector Figura 1 Referencia N mero de modelo Descripci n Materiales Abertura de la compuerta Resistencia de la compuerta C1 3100064 Conector del arn s Nano Lok...

Страница 27: ...nto SRD Modelos ANSI Modelos OSHA Rango de capacidad 130 lb 310 lb 59 kg 140 kg 311 lb 420 lb 141 191 kg Fuerza m xima de detenci n 1 350 lbf 6 kN 1 350 lbf 6 kN Fuerza de detenci n promedio 900 lbf 4...

Страница 28: ...capacidad de su subsistema de conexi n Consulte las instrucciones del fabricante correspondientes a cada componente de su sistema para conocer los requisitos de capacidad 2 3 RIESGOS AMBIENTALES el us...

Страница 29: ...16 kN 3600 lb o superior C En un enganche falso en el que el tama o o la forma del conector o el elemento de conexi n no sean compatibles y sin confirmaci n visual parecer a estar completamente conect...

Страница 30: ...de la activaci n del dispositivo de desaceleraci n hasta que se detiene El estiramiento del arn s HS es la cantidad de holgura que se extiende desde el arn s del usuario cuando este est suspendido por...

Страница 31: ...0 6 2 0 9 3 1 2 4 1 5 5 m ft 0 3 1 0 6 2 0 9 3 1 2 4 1 5 5 0 3 1 0 6 2 0 9 3 1 2 4 2 1 Separaci n de ca da FC 59 100 kg 130 220 lb 100 140 kg 220 310 lb 2 0 m 6 6 ft 2 1 m 6 9 ft 3 3 m 10 7 ft 3 5 m...

Страница 32: ...cuerpo completo del usuario Este formato permite un transporte m s sencillo del SRD y asegura que este est a mano al moverse entre puntos de anclaje Los m todos para montar un SRD en un arn s var an...

Страница 33: ...e red del arn s C INTERFAZ DEL MOSQUET N consulte la Figura 10 como referencia Estas instrucciones se aplican al mosquet n 2000159 cuando se usa con modelos de arneses de cuerpo completo espec ficos 1...

Страница 34: ...irar hacia la nariz para dejar espacio para el ojal giratorio entre la hebilla y la espalda del conector 4 Coloque el mosquet n doble alrededor de las cintas del arn s Con la compuerta orientada hacia...

Страница 35: ...das o la fuerza de impacto ret relo del servicio inmediatamente Etiqu telo claramente con la inscripci n NO USAR Consulte la Secci n 5 para obtener m s informaci n 4 3 FUNCIONAMIENTO antes de usar un...

Страница 36: ...e su compatibilidad con los SRD Los SRD se pueden utilizar con un sistema horizontal solo si ambos productos son adecuado para dicho uso Los valores de espacio libre de ca da necesarios que se present...

Страница 37: ...el producto debe destruirse 5 4 VIDA TIL DEL PRODUCTO la vida til del producto est determinada por las condiciones de trabajo y el mantenimiento Mientras el producto pase los criterios de inspecci n p...

Страница 38: ...exhaustiva de t rminos y definiciones visite nuestro sitio web www 3m com FallProtection ifu glossary PERSONA AUTORIZADA persona designada por el empleador para que realice tareas en una ubicaci n en...

Страница 39: ...39 Figura 13 Ubicaci n de la etiqueta RFID Figura 14 Etiquetas del producto 2 B A C A B C...

Страница 40: ...40 Figura 14 Etiquetas del producto A B C D B D B D A C...

Страница 41: ...es de bloqueo y pasadores deben funcionar correctamente L nea de vida de cinta Figura 14 3 Inspeccione el tejido en busca de cortes A rasgaduras B fibras rotas rasgaduras abrasi n suciedad excesiva C...

Страница 42: ...42 Figura 14 Inspecci n general 1 2 3 A C B B A C A A B D C B A Figura 15 Inspecci n del absorbedor de energ a D B C A C A...

Страница 43: ......

Страница 44: ...ranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and wa...

Отзывы: