SECTION 8: MAINTENANCE

Depending on your water quality, it may be necessary to perform maintenance on your fi lter system in order to ensure continued performance. This is to both low 
pH, high manganese and the sacrifi cial nature of the fi lter media. The severity of your pH or the amount of water used will determine how often the fi lter will need 
to be serviced. To correct this condition, it will be necessary to add MPH adder to the fi lter bed. The part number is MPH04, and can be purchased as a single unit 
or in a case of 6, which is MPH0406. Either of these items can be purchased through our wholesale chain in your area. MPH0406 is a 3 ½ pound jar of pH boost-
ing material that replenishes the same material that was dissolved into your water to make Iron and Manganese reduction possible.

3M Purifi cation Inc. recommends that you test your treated water pH once a quarter. When Iron is the only problem, a water pH needs to be 7.2 higher. When Man-
ganese and Iron are present, the treated water pH needs to 8.2 or higher. The levels can be checked on location with the use of an inexpensive pH test kit that can 
be purchased locally or from 3M Purifi cation Inc.. Our part number is “17N” . When the pH falls below the recommended level and Iron or Manganese is bleeding 
through into the fi nished water, it is time to add the MPH adder component to the fi lter. The amount of material to add to a fi lter is as follows.

 

Standard bed fi lters (identifi ed by an “S” in the model number, i.e. APIF100S or no “S”, i.e. APIF100)

 

 

1- 3 ½ pound jar of MPH adder for each cubic foot of fi lter material

 

Manganese bed fi lters (Identifi ed by an “M” in the model number, i.e APIF100M)

 

 

2- 3 ½ pound jars of MPH adder for each cubic foot of fi lter material.

Bed Type

Filter Models

(Number of Jars to Add)

Standard Filter 

Media

APIF100

APIF100J

APIF100PT

(1)

APIF150

APIF150J

APIF150PT

(1 ½)

APIF200

APIF200J

APIF200PT

(2)

APIF300

APIF300J

APIF300PT

(3)

Manganese 

Filter Media

APIF100M

 APIF100MPT

APIF100MJ

(1)

APIF150M

APIF150MPT

APIF150MJ

(1 ½)

APIF200M

APIF200MPT

APIF200MJ

(2)

APIF300M

APIF300MPT

APIF300MJ

(3)

Step by step procedure to add MPH adder to your Iron Reduction System.
    
1)  Turn the inlet and outlet knobs of the bypass valve located on the back side of the control valve. See fi gure 3 in section 3 for proper orientation.
2)  Manual initiate a backwash cycle to relieve water pressure from the inside of the fi lter.
3)  Disconnect the drain line and set aside.
4)  Remove the latch on the clamp assembly and separate the clamp assembly. Set aside in a secure location for reuse.
5)  Slowly lift the control valve straight up and off the fi lter vessel. Do not rock the control from side to side as this might damage the controller or distributor 

tube.

6)  Using the funnel and centering device supplied with the unit originally, install over the distributor tube and inside the opening of the fi lter vessel to aid in add-

ing the MPH adder material.

7)  Using a ½ diameter fl exible tubing siphon about 12” of water from the fi lter vessel to allow for adding the MPH adder.
8) 

Pour the recommended amount of MPH adder into the fi lter media and add water back to fi lter to expel any air pockets in the fi lter vessel.

9) 

Reinstall the control valve back on top of fi lter vessel. You may want to apply some silicone lubricant to the O-rings, distributor tube and the inside of the 
fi lter vessel opening to facilitate for easier installation. Allow the control valve to rest on the fi lter vessel fl ange and with one steady downward motion push 
the control into the vessel opening to seat properly. Manually stage control valve to the service position. Refer to Page 3-8, “HOW TO MANUALLY INITIATE 
IMMEDIATE REGENERATION”.

10)  Reinstall the clamp assembly around both the control valve and fi lter vessel fl ange and secure the latch. See Figure 7 for proper orientation in on page 3-12.
11)  Connect both the bypass and the drain line to the control valve and hand tighten only the connection nuts.
12)  Slowly open the inlet side of the bypass and pressurize the fi lter, check for leaks, correct if necessary. 
13)  Slowly open the outlet side of the bypass and pressurize the dwelling.
14)  Manual stage the control to backwash and clean the fi lter media of any fi nes that would be present till clear. Allow the control to complete regeneration cycle 

completely and return to service. Refer to page 3-8, “HOW TO MANUALLY INITIATE IMMEDIATE REGENERATION”.

  

8-1

Содержание APIF100

Страница 1: ...100J APIF100M APIF100PT APIF100MPT APIF100MJ APIF150 APIF150J APIF150M APIF150PT APIF150MPT APIF150MJ APIF200 APIF200J APIF200M APIF200PT APIF200MPT APIF200MJ APIF300 APIF300J APIF300M APIF300PT APIF300MPT APIF300MJ INSTR2188 0710 Installer please leave with homeowner Homeowner retain for future reference ...

Страница 2: ......

Страница 3: ... to service To reduce the risk associated with a hazardous voltage If the home electrical system requires use of the cold water system as an electrical safety ground a jumper must be used to ensure a sufficient ground connection across the filter installation piping refer installation to qualified personnel Do not use the system if the power cord is damaged contact qualified service personnel for ...

Страница 4: ... plastic fittings or plastic plumbing On plastic fittings never use pipe sealant or pipe dope Use PTFE thread tape only pipe dope properties may deteriorate plastic Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if over tightening occurs Do not install in direct sunlight or outdoors Mount system in such a position as to prevent it from being struck by ...

Страница 5: ...ed Description and Operation of the System The Iron Reduction System consists of two major components which are 1 HYDRO CHARGER located between the well head and the pressure tank which adds a small amount of air to the iron laden water whenever the well pump runs 2 A backwashing type filter containing a special media that causes the iron in the Hydro Charged water to precipitate throughout the fi...

Страница 6: ...on As little as 0 05 ppm of manganese can produce a brownish or black stain The ability of the Iron Reduction System to reduce manganese depends on its concentration and the pH of the water Although not specifically designed for the reduction of manganese the oxidation of manganese is very similar to that of iron therefore a pH of 8 2 or higher must be obtained When this pH level is achieved the p...

Страница 7: ...damage due to water leakage Do not install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention 2 The pumping rate of your well pump must be sufficient for satisfactory operation of the Hydro Charger and to backwash the filter For model APIF100 the required rate is 5 gpm refer to Specifications and Operating Data for the backwash requi...

Страница 8: ...on Reduction System will perform satisfactorily with either a captive air bladder type pressure tank or a standard air to water type with an air volume control air relief valve the bladder type requires more careful adjustment of the Hydro Charger to prevent gasses from collecting in the pressure tank and the head area of the filter tank IMPORTANT A properly sized pressure tank of either style wil...

Страница 9: ... that runs toward the water heater CAUTION To reduce the risk associated with property damage due to plugged water lines Pay particular attention to correct orientation of control valve Water flow should match arrow on control valve The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used 4 Before commencing the installation it is advisab...

Страница 10: ...NOID VALVE CHECK VALVE TREATED WATER TREATED BRINE MAKER SOFTENER IRON REDUCTION SYSTEM SOFT WATER TREATED WATER TREATED BRINE MAKER SOFTENER SOFT WATER TREATED WATER TREATED HYDRO CHARGER HYDRO CHARGER HYDRO CHARGER CHECK VALVE IRON REDUCTION SYSTEM IRON REDUCTION SYSTEM STANDARD WELL INSTALLATION SPLIT STREAM INSTALLATION PUBLIC WATER SUPPLY INSTALLATION Figure 1 CAUTION To reduce the risk assoc...

Страница 11: ...ail fill the filter vessel with water to saturate the filter media and expel any air that may be present remove the extension tube cap and funnel and save for future servicing g Using a clean dry rag wipe the opening of the media tank to remove any dust or residue from the opening to receive the control valve Apply silicone lubricant to the filter vessel flanged opening and control valve O rings t...

Страница 12: ...supplied bypass valve requires maintenance in order to provide undisturbed water use Figure 2 HYDRO CHARGER INSTALLATION Step 4 Turn back on the power to the well pump and pressurize the water lines to allow for adjustment of the Hydro Charger Check for leaks and adjust as necessary IMPORTANT NOTES Do not apply heat near Hydro Charger as damage may occur On badly scaled older plumbing systems it m...

Страница 13: ... the use of paste of any kind will void the factory warranty Do not let the connection fittings support the plumbing properly support the plumbing as required 3 Slide the nut on first closed and against the threads then slip ring onto the fitting ensuring it set correctly in groove then the O ring last Use Silicone lubricant to allow for easier insertion of parts into one another 4 Hand tighten th...

Страница 14: ...r if it was drained at any time during the installation Check for leaks on all connections before leaving the job site correct as required Step 15 Manually initiate regeneration of the Iron Reduction System by referring to the How To Manually Initiate Immediate Regeneration section of Control Valve settings on Page 3 8 Step 16 Once the valve is in the backwash position C1 appears on the display sl...

Страница 15: ...s APIF100 APIF100J APIF100M APIF100PT APIF100MPT and APIF100MJ Models APIF150 APIF150J APIF150M APIF150PT APIF150MPT and APIF150MJ Persons in Family IRON CONTENT PPM 2 4 6 8 10 12 14 16 1 12 12 12 12 12 12 12 12 2 12 12 12 12 12 12 6 6 3 12 12 12 12 6 6 6 4 4 12 12 12 6 6 6 4 4 5 12 12 12 6 6 4 4 3 6 12 12 12 6 4 4 4 3 7 6 6 4 4 4 3 2 2 8 6 4 4 4 3 2 2 2 3 6 BACKWASH FREQUENCY SCHEDULE ...

Страница 16: ...IF300MPT and APIF300MJ Persons in Family IRON CONTENT PPM 10 12 14 16 18 20 22 24 26 28 30 32 1 12 12 12 12 12 12 12 12 12 12 12 12 2 12 12 12 12 12 12 12 12 12 12 12 6 3 12 12 12 12 6 12 6 6 6 6 6 6 4 12 12 12 6 6 6 6 6 6 6 6 4 5 12 12 6 6 6 6 6 6 4 4 4 4 6 12 6 6 6 4 6 4 4 4 4 3 3 7 6 6 6 6 4 4 4 4 6 3 3 3 8 6 6 6 4 4 4 4 3 3 3 3 2 9 6 6 4 4 4 4 3 3 3 2 2 2 10 6 6 4 4 4 3 3 3 2 2 2 2 Step 18 The...

Страница 17: ...conds Note Once a manual regeneration has been initiated it cannot be stopped STEP 2 Once the valve display is in C1 it is in Backwash mode To advance to Rapid Rinse press and hold and buttons simultaneously until valve motor starts usually about three 3 seconds STEP 3 Once the valve display is in C4 it is in Rapid Rinse To advance to the display mode press and hold and buttons simultaneously unti...

Страница 18: ...isplay to the closest hour by pressing or button An arrow will appear in the display pointing to PM during PM hours STEP 3 Press and release SET HOUR and buttons simultaneously to return to the display mode Note Your Iron Reduction System is factory set to regenerate at 1 00 AM HOW TO CHANGE THE REGENERATION PROGRAM SETTINGS STEP 1 Press and hold SET HOUR and buttons simultaneously until the displ...

Страница 19: ...ile memory The following chart shows the time for the backwash and rapid rinse cycles for the three available programming options Regeneration Cycles and Times for Different Programs Program Number Length of Cycle Times Minutes BACKWASH C1 RAPID RINSE C4 P7 6 4 P8 10 6 P9 14 8 3 10 Note Your Iron Reduction System is factory preset to program number P7 changing the setting to P8 or P9 is rarely nee...

Страница 20: ...play is the days remaining until the next regeneration If the days remaining is equal to one a regenera tion will occur at the next preset regeneration time The user can scroll between displays as desired If the system has called for a regeneration that will occur at the preset time of regeneration the arrow will point to Regen Regeneration Mode Typically system is set to regenerate at a time of l...

Страница 21: ...K SECONDARY PRESSURE TANK on SPLIT STREAM type installation and NORMALLY CLOSED SOLENOID VALVE 4 Install PRESSURE SWITCH after HYDRO CHARGER and wire it to SOLENOID VALVE SECONDARY PRESSURE SWITCH on SPLIT STREAM Set HIGH pressure on PRESSURE SWITCH which controls opening and closing of SOLENOID VALVE 2 to 3 psi LOWER than LOW pressure on PRIMARY PRESSURE SWITCH EXAMPLE If PRIMARY PRESSURE SWITCH ...

Страница 22: ...3 13 Figure 10 Figure 11 Figure 8 Figure 9 ...

Страница 23: ...nto mineral bed Then IMMEDIATELY 3 Close main water supply valve or turn power off to pump and proceed with filter installation During time required to install filter system iron fouled softener resin will be chemically cleaned 4 After filter installation is completed final adjustments made with water turned and the brine draw tube reconnected manually reposition timer on softener to BACK WASH pos...

Страница 24: ...tside spigots a swimming pool geothermal heat pump or other high water usage devices or activities If your application includes any of these and you have already determined your model Iron Reduction System is capable of handling the flow rates involved refer to the next paragraph for instructions on setting Backwash Frequency TO SET BACKWASH FREQUENCY FOR COMMERCIAL MODELS AND NON STANDARD HOUSEHO...

Страница 25: ...the circuit board and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires broken or disconnected motor failure e Check motor and wiring Replace motor if necessary f Drive gear label dirty or damaged missing or broken gear f Replace or clean drive gear g Drive bracket incorrectly aligned to drive bracket g Reseat drive bracket properly h PC board incorrectly ...

Страница 26: ... dealer b Filter bed over loaded with precipitated iron due to insufficient back wash or failure to backwash due to malfunction of control timer or unplugged control valve power cord b Upon correction of problem increase backwash frequency if problem determined to be insufficient frequency manually backwash until backwash water starts to clear in more severe iron fouling cases filter bed may need ...

Страница 27: ... Backwash Flow Rate gpm Backwash Flow Rate lpm 1 0 ft3 053 5 3 20 1 1 5 ft3 053 5 3 20 1 2 0 ft3 075 7 5 28 4 3 0 ft3 100 10 0 37 9 Inlet Outlet Tube Opening a 1 Universal Elbow b 1 Straight brass sweat fitting c 1 Plastic male NPT fitting Distributor Tube Opening 1 05 OD 3 4 NPS Tank Thread 2 1 2 8 NPSM to Flanged Adapter Control Valve Weight 4 5 lbs 2 0 kg PC Board Memory Nonvolatile EEPROM elec...

Страница 28: ...28 4 1 2 5 12 x 54 30 x 137 12 30 16 41 63 160 257 116 6 3 0 0 08 26 11 8 90 000 5 18 9 12 45 5 2 13 8 10 68 9 10 37 9 1 2 5 14 x 65 36 x 165 13 33 16 41 74 188 353 160 2 Maximum Operating Temperature 110 F 43 3 C Electrical requirements 110V 60Hz Operating Pressure 20 100 psi 138 689 kPa Specifications subject to change without notice 7 2 IMPORTANT NOTE 1 Replenishment of pH adjusting component o...

Страница 29: ...ro charger Complete HC10 HC10 HC10 HC10 12 Quick Release Clip QRC20 QRC20 QRC20 QRC20 13 Air Check Cap HC10 2 HC10 2 HC10 2 HC10 2 14 Air Check HC10 10 HC10 10 HC10 10 HC10 10 15 O ring Bypass Screw HC10 4 HC10 4 HC10 4 HC10 4 16 Bypass Screw HC10 5 HC10 5 HC10 5 HC10 5 17 Screw Retainer HC10 6 HC10 6 HC10 6 HC10 6 18 Nipple 1 NPT Qty 2 Includes Items 12 20 PKNPL100 PKNPL100 PKNPL100 PKNPL100 19 N...

Страница 30: ...CE STACK ASSEMBLIES Reference No Part No Description Quantity 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assembly 1 3 V3178 Drive Back Plate 1 4 V3001 Piston Downflow Assembly 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O ring 215 Pilot Tube 1 NOT SHOWN V3001 Downflow body Assembly 1 7 4 2 4b 6 1 7 3 8 4a 4 ...

Страница 31: ...bly 1 2 V3107 01 Motor 1 3 V3106 01 Drive Bracket Spring Clip 1 4 V3108TC Time Clock PC Board 1 5 V3110 Drive Gear 12 x 36 1 6 V3109 Time Clock Cover 1 V3002TC Time Clock Drive Assembly 1 NOT SHOWN V3186 AC Adapter 110V 12V 1 Drawing number parts 2 through 6 may be purchased as a complete assembly part V3202 7 5 1 4 3 2 6 5 ...

Страница 32: ...No Part No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O ring 2 7 6 1 2 3 3 1 2 V3151 1 Quick Connect Nut 2 V3150 Split Ring 2 V3105 O ring 215 2 V3191 Vertical Bypass Adapter 1 Not Shown Part V3191 01 Vertical Bypass Adapter ...

Страница 33: ...1 Quick Connect Nut 2 2 V3150 1 Quick Connect Split Ring 2 3 V3105 1 Quick Connect O Ring 215 2 4 V3188 1 Quick Connect Brass Sweat Assembly 2 Part V3007 04 1 Plastic Male NPT Assembly Reference No Part No Description Quantity 1 V3151 1 Quick Connect Nut 2 2 V3150 1 Quick Connect Ring 2 3 V3105 1 Quick Connect O Ring 215 2 4 V3164 1 NPT Quick Connect Plastic Male Assembly 2 1 2 4 3 1 3 2 4 ...

Страница 34: ...LK 5 8 Insert Sleeve 1 3 V3192 Quick Connect 3 4 Drain Elbow Nut 1 4 V3158 01 Quick Connect 3 4 Drain Elbow 1 5 V3163 O ring 019 1 6 V3159 01 Drain Line Flow Control Retainer Assembly 1 7 V3162 042 4 2 gpm Drain Line Flow Control Button 1 7 V3162 053 5 3 gpm Drain Line Flow Control Button 1 7 V3162 075 7 5 gpm Drain Line Flow Control Button 1 7 V 3262 100 10 0 GPM Drain Line Flow Control Button 1 ...

Страница 35: ...d MPH adder to your Iron Reduction System 1 Turn the inlet and outlet knobs of the bypass valve located on the back side of the control valve See figure 3 in section 3 for proper orientation 2 Manual initiate a backwash cycle to relieve water pressure from the inside of the filter 3 Disconnect the drain line and set aside 4 Remove the latch on the clamp assembly and separate the clamp assembly Set...

Страница 36: ...ed warranty card or call 1 800 222 7880 or mail your request to 3M Purification Inc 400 Research Parkway Meriden CT 06450 3M is a trademark of 3M Company 2010 3M Company All rights reserved 3M Purification Inc 400 Research Parkway Meriden CT 06450 1 800 222 7880 www 3Mpurification com ...

Отзывы: