background image

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

Read, understand, and follow all safety information contained in these instructions prior 

to installation and use of the Aqua-Pure® filters. Retain these instructions for future 

reference.
Intended use:

The AP101T, AP11T, AP141T and AP102T Whole House Filters are intended for use in filtering potable

water in homes and have not been evaluated for other uses.  These filters are typically installed at the 

point of entry, and should be installed by qualified professional installers according to these installation 

instructions.

Indicates a potentially hazardous situation, which, if not avoided, could result in death 

or serious injury and/or property damage.

To reduce the risk associated with property damage due to water leakage or flooding:

 • 

Read and follow

 Use Instructions before installation and use of this system.

  • Installation and Use 

MUST

 comply with all state and local plumbing codes.

  • Protect from freezing.  Drain filter when temperatures drop below 40°F (4.4°C).

 • 

Do not

 install systems in areas where ambient temperatures may go above 110° F (43.3° C).

 • 

Do not

 install on hot water supply lines. The maximum operating water temperature of this system is 100°F (37.8°C).

 • 

Do not

 install if water pressure exceeds 125 psi (862 kPa).  If your water pressure exceeds psi (552 kPa), you must install a

       pressure limiting valve.  Contact a plumbing professional if you are uncertain how to check your water pressure.

 • 

Do not 

install where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer

       arrester.  Contact a plumbing professional if you are uncertain how to check for this condition.

  • Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion

       must be installed.

  • Where a booster pump is installed on a water system, you must maintain and inspect the attached pressure switch regularly

       in accordance with the booster pump manufacturer’s instructions.  Contact a plumbing professional if you are uncertain how

       to maintain your booster pump system.

  • Where a booster pump is installed on a water system, you must install an appropriate pressure relief valve.  Pressure relief

       valve must be maintained and inspected every 6 months.  Contact a plumbing professional if you are uncertain how select/

       install/maintain a pressure relief valve.

    • Where a booster pump is installed on a water system, you must install an appropriate pressure regulating valve and regulate

       water pressure to <80psi.  Contact a plumbing professional if you are uncertain how select/install/maintain a pressure

       regulating valve.

NOTICE

NOTICE

WARNING

WARNING

To reduce the risk associated with ingestion of contaminants due to use with water that is microbiologically 

unsafe or of unknown quality:

   

Do not use with water that is microbiologically unsafe or of unknown quality without adequate 

     disinfection before or after the system.

To reduce the risk associated with choking: 

    

Do not

 allow children under 3 years of age to have access to small parts during the installation

 

of this product.

To reduce the risk of physical injury:

•     Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.

Indicates a potentially hazardous situation, which, if not avoided, may result in 

property damage.

2

Содержание AP11T

Страница 1: ... Operating Instructions For Standard Sized Whole House Water Filters AP11T AP101T AP141T and AP102T Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenance instructions ...

Страница 2: ...1 ...

Страница 3: ...r hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition Where a backflow prevention device is installed on a water system a device for controlling pressure due to thermal expansion must be installed Where a booster pump is installed on a water system you must maintain and inspect the attached pressure switch regularly in accordance with the booster pu...

Страница 4: ...illing tool when selecting the position to mount the bracket Mount system in such a position as to prevent it from being struck by other items used in the area of installation Ensure that the location and fasteners will support the weight of the system when installed and full of water Ensure all tubing and fittings are secure and free of leaks SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER...

Страница 5: ... overtighten 4 Place brass locking nuts and ferrules as shown in the diagram 5 Place filter housing with male adapters onto incoming and outgoing plumbing Make sure you correctly align the IN end of the housing with the incoming water line as shown below Tighten locking nuts securely with the wrench 6 Slowly turn water supply on open shut off valve and check for leaks Before starting shut off main...

Страница 6: ...elt and cartridge is sealed Hand tight is sufficient However be sure not to overtighten or force housing 6 A11T Turn on inlet valve and depress pressure relief button until air is purged from filter Release button and turn on outlet valve AP101T AP141T and AP102T Turn valve hand to the ON Position Wait until filter is filled with water and check for leaks Open and close the valve once to released ...

Страница 7: ...t will vary with local water conditions and water consumption 3M PURIFICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IM PLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING CUSTOMER OR USAGE OF TRADE If the Product fails to satisfy this Limi...

Страница 8: ...según las instrucciones del fabricante de la bomba de carga Co muníquese con un plomero profesional si tiene dudas acerca de cómo mantener su sistema de bomba de carga Donde esté instalada la bomba de carga en el sistema de agua debe instalar una válvula de alivio de presión adecuada La válvula de alivio de presión debe mantenerse e inspeccionarse cada 6 meses Comuníquese con un plomero profesiona...

Страница 9: ...r foración cuando se selecciona el lugar donde se va a instalar el soporte del filtro Instale sistema en una posición tal que se evite ser golpeado por otros objetos usados en el área de instalación Asegúrese de que el lugar y las fijaciones aguantarán el peso del sistema cuando esté instalado y lleno de agua Vea de que todas las tuberías y acoples estén seguros y sin fugas CIERRE EL SUMINISTRO DE...

Страница 10: ...s de seguridad de latón y los regatones como se indica en el diagrama 5 Ponga el filtro en el armazón con los adaptadores macho en la cañería de entrada y de salida Asegúrese de alinear cor rectamente la entrada IN del armazón con la cañería de la entrada de agua como se indica a continuación Ajuste las tuercas de seguridad apretadamente con la llave 6 Abra lentamente la entrada de agua abra la vá...

Страница 11: ...tenido y el cartucho esté sellado Apretarlo con la mano es suficiente Sin embargo tenga cuidado de no apretarlo demasiado o forzar el armazón 6 A11T Abra la válvula de entrada y oprima el botón de eliminación de la presión hasta que se purgue el aire del filtro Libere el botón y abra la válvula de salida AP101T AP141T and AP102T Ponga la manija de la válvula en la posición ACTIVADA ON Espere que l...

Страница 12: ...on las instrucciones de instalación y uso No se garantiza la vida útil de los cartuchos de filtro o membranas ya que varía de acuerdo con las condiciones y el consumo de agua local 3M PURIFICATION INC NO SE COMPROMETE A OTRAS GARANTÍAS O CONDICIONES EXPRESAS O IMPLÍCITAS INCLUYENDO ENTRE OTRAS LAS GARANTÍAS O CONDI CIONES IMPLÍCITAS DE COMERCIABILIDAD O IDONEIDAD PARA UN FIN DETERMINADO O GARANTÍA...

Страница 13: ...d eau est supérieure à 862 kPa 125 psi Communiquer avec un plombier qualifié si vous êtes incertain de la méthode de vérification pour votre pression d eau Ne pas installer à un endroit sujet aux coups de bélier Un antibélier doit être installé en présence de coups de bélier Communiquer avec un plombier qualifié si vous êtes incertain de la méthode de vérification de cette condition Lorsqu un disp...

Страница 14: ...anchéité ou d enduit d enrobage pour tuyau sur les adaptateurs en plastique Utiliser uniquement un ruban de polytétrafluoroéthylène PTFE pour filet pour éviter la détérioration du plastique occasionné par l enduit d enrobage Utiliser soigneusement les pinces ou les clés à tuyau pour serrer les adaptateurs pour éviter tout dommage occasionné par un serrage excessif Ne pas installer directement sous...

Страница 15: ...n laiton tel qu illustré sans le schéma 5 Placer le filtre dans le boîtier avec les adaptateurs mâles raccordés à la plomberie d entrée et de sortie S assurer d aligner correctement l entrée du boîtier IN avec le tuyau d alimentation en eau tel qu illustré ci dessous Resserrer solidement les écrous de verrouillage à l aide de la clé 6 Rétablir doucement l alimentation en eau ouvrir la soupape d ar...

Страница 16: ...ler la cartouche Il est suffisant de resserrer à la main De plus il est important de ne pas trop serrer ni de forcer le boîtier 6 A11T Tourner la soupape d admission et appuyer sur le bouton de décompression jusqu à ce que tout l air soit expulsé du filtre Relâcher le bouton et ouvrir la soupape de sortie AP101T AP141T and AP102T Tourner la poignée de la soupape à ON Attendre jusqu à ce que le fil...

Страница 17: ...tant du non respect des instructions d installation et d utilisation Aucune garantie n est donnée quant à la durée de vie de la cartouche de filtrage ou de la membrane ceci pouvant varier selon la qualité de l eau locale et la consommation d eau 3M PURIFICATION INC NE DONNE AUCUNE AUTRE GARANTIE OU CONDITION EXPRESSE OU IMPLICITE INCLUANT MAIS SANS S Y LIMITER TOUTE GARANTIE IMPLICITE OU CONDITION...

Страница 18: ...NOTES 17 ...

Страница 19: ...NOTES 18 ...

Страница 20: ...of 3M Company 2014 3M Company All rights reserved 34 8715 4664 3 3M Purification Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 222 7880 Worldwide 203 237 5541 Fax 203 238 8701 www aquapure com www 3Mpurification com 19 ...

Отзывы: