SAFETY INFORMATION
EXPLANATION OF SIGNAL WORD CONSEQUENCES
Read, understand, and follow all safety information contained in these instructions prior
to installation and use of the Aqua-Pure® filters. Retain these instructions for future
reference.
Intended use:
The AP101T, AP11T, AP141T and AP102T Whole House Filters are intended for use in filtering potable
water in homes and have not been evaluated for other uses. These filters are typically installed at the
point of entry, and should be installed by qualified professional installers according to these installation
instructions.
Indicates a potentially hazardous situation, which, if not avoided, could result in death
or serious injury and/or property damage.
To reduce the risk associated with property damage due to water leakage or flooding:
•
Read and follow
Use Instructions before installation and use of this system.
• Installation and Use
MUST
comply with all state and local plumbing codes.
• Protect from freezing. Drain filter when temperatures drop below 40°F (4.4°C).
•
Do not
install systems in areas where ambient temperatures may go above 110° F (43.3° C).
•
Do not
install on hot water supply lines. The maximum operating water temperature of this system is 100°F (37.8°C).
•
Do not
install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds psi (552 kPa), you must install a
pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
•
Do not
install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
• Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion
must be installed.
• Where a booster pump is installed on a water system, you must maintain and inspect the attached pressure switch regularly
in accordance with the booster pump manufacturer’s instructions. Contact a plumbing professional if you are uncertain how
to maintain your booster pump system.
• Where a booster pump is installed on a water system, you must install an appropriate pressure relief valve. Pressure relief
valve must be maintained and inspected every 6 months. Contact a plumbing professional if you are uncertain how select/
install/maintain a pressure relief valve.
• Where a booster pump is installed on a water system, you must install an appropriate pressure regulating valve and regulate
water pressure to <80psi. Contact a plumbing professional if you are uncertain how select/install/maintain a pressure
regulating valve.
NOTICE
NOTICE
WARNING
WARNING
To reduce the risk associated with ingestion of contaminants due to use with water that is microbiologically
unsafe or of unknown quality:
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
To reduce the risk associated with choking:
•
Do not
allow children under 3 years of age to have access to small parts during the installation
of this product.
To reduce the risk of physical injury:
• Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.
Indicates a potentially hazardous situation, which, if not avoided, may result in
property damage.
2