7.4
Squeeze gel end seal to insure a seal between layers and cables.
Note:
Closure assembly must rest on end seal when placed over
the splice. Move end seal upward, if necessary.
7.5
Cut off top of foil bag which contains desiccant at dotted line and
secure bag at base of wire work area with a cable tie.
Note:
Carefully follow health, safety and environmental
information given on product label or Material Safety Data
Sheet for desiccant bag.
7.6
Remove cardboard insert and pull core tail through the center of PST
until core is even with PST edge.
7.7
Slide PST over closure so that PST tail is pointed toward the top
of the closure. The core tail MUST be unwound upward.
Position PST bottom edge between the bottom of the wire form
latch and the base's top rib.
Note:
Optional method is to put closure over the splice bundle
and position PST 2" (51 mm) below the gel end seal.
While holding the PST and closure with one hand,
unwind the core by pulling on the core tail with the other
hand in an upward and outward COUNTERCLOCKWISE
direction.