manualshive.com logo in svg
background image

April 2001
78-8122-1737-6-A

4220CUE-6000 Cabinet

Instructions

Содержание 4220CUE-6000

Страница 1: ...April 2001 78 8122 1737 6 A 4220CUE 6000 Cabinet Instructions ...

Страница 2: ...ts 4 3 0 Installation 5 4 0 Cable Port Sealing 5 5 0 Shield Bonding 5 6 0 Cable Preparation Pre Termination Plugging and Splicing 6 7 0 Binder Post Identification 6 8 0 Jumper Wire Installation and Routing 7 9 0 Accessories Installation 8 ...

Страница 3: ... of 500 pairs each The cabinet is also the entry point for the fiber optic cables into the CUE The CUE arrives on site with 2000 derived pairs electronic equipment cables terminated in 4005 CBM Modules or 710 SC Connectors located behind the center drop down frame The Derived Pairs will be assigned by local engineering and spliced by the construction field forces The Talk Block on the left hand si...

Страница 4: ...d Bars one with green ground straps from the derived pairs G SS5 XXX 500 pair Frame Panels with 4320 Self Strip Termination Blocks H Cable Base Panels I Duct Cable Skirts J Cable Ports Included in Cabinet One Fiber Port 4 Metal Port Two Copper Ports 4297 3 Port Kit 3 1 4 openings 4298 Flex Port Kits Option 4297 2 Port Kit 4 openings A B C D E G F A B C D H I J copper J fiber F ...

Страница 5: ...et and the 2001 4000 pair count cable s on the right side of the cabinet All copper cables must have 18 feet minimum length above the pad 4 0 Cable Port Sealing 4 1 The two types of cable ports that are the standard in the 4220CUE 6000 are the 4 inch Metal Port for the fiber cable s and or innerduct s and the two 4297 3 Port Kit 3 holes with 3 1 4 opening for the copper cable s The 4297 2 Port Kit...

Страница 6: ... Connectors of the blocks Tie wrap the group to the frame and store the connectors behind the blocks 3 Continue splicing tying and storing until the frame is complete Make sure the frames will close 4 Repeat on the other panels and frame Note When using 3M MS2 Modules or 3M 710 Connectors follow safety health and environmental information on appropriate material safety data sheets 6 2 Derived Cabl...

Страница 7: ...e outer liner as shown 7 5 Fill in Binding Post Log on cabinet door 8 0 Jumper Wire Installation and Routing 8 1 Make sure wires have clean cut ends and bend the last 1 2 to 3 4 of wire 90 The post slot must be in the vertical insertion position 8 2 Split pair TIP left RING right at assigned post positions Insert wire into port and through the post until the wire extends out the exit port 8 3 With...

Страница 8: ...ility associated with such use Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture as of the date of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be...

Отзывы: