![3M 1000 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/3m/1000/1000_user-manual_443859058.webp)
1 2 3 4 5
6
7
8
9
Reader Startup Tool
46
3M Compact RFID Reader 1000 User’s Guide
6.6.5.
Power Ramp Tool
The Power Ramp Tool determines the minimum power to activate a tag and
can help determine tag quality. This activation power level can help
determine the read range at various attenuation levels and, for AVI
applications, can help determine the "read-zone" or an antenna pattern.
The tool starts by configuring the reader to start transmitting at a low
attenuation level (usually 0.1 dBm) and increments the level until it
observes a response from the tag. The transmitter is turned off and the
minimum value to activate the tag for a given antenna and distance is
reported.
The Power Ramp controls include:
Increment Rate (ms)
– Time tool stays at a particular power level
before incrementing to the next power level.
Initial Attenuation Level (dBm)
– Starting attenuation level.
Attenuation Decrement (dBm)
– Step-size for attenuation
decrement.
Antennas
section allows you to select which antenna(s) to test with.
Filter
section allows you to apply a filter to only look for a particular tag.
Содержание 1000
Страница 1: ...3M Compact RFID Reader 1000 User s Guide ...
Страница 2: ...ii 3M Compact RFID Reader 1000 User s Guide ...
Страница 12: ...Contents xii 3M Compact RFID Reader 1000 User s Guide This page intentionally left blank ...
Страница 86: ...1 2 3 4 5 6 7 8 9 Reader Configuration Tool 74 3M Compact RFID Reader 1000 User s Guide ...
Страница 111: ...Appendix B USB Port Setup 3M Compact RFID Reader 1000 User s Guide 99 8 Click the Change Settings button ...
Страница 120: ...3M Compact RFID Reader 1000 User s Guide This page intentionally left blank ...
Страница 121: ...3M Compact RFID Reader 1000 User s Guide ...